• Title/Summary/Keyword: Fluid consumption

Search Result 261, Processing Time 0.022 seconds

GLOBAL EXISTENCE OF WEAK SOLUTIONS FOR A KELLER-SEGEL-FLUID MODEL WITH NONLINEAR DIFFUSION

  • Chung, Yun-Sung;Kang, Kyungkeun;Kim, Jaewoo
    • Journal of the Korean Mathematical Society
    • /
    • v.51 no.3
    • /
    • pp.635-654
    • /
    • 2014
  • We consider the Cauchy problem for a Keller-Segel-fluid model with degenerate diffusion for cell density, which is mathematically formulated as a porus medium type of Keller-Segel equations coupled to viscous incompressible fluid equations. We establish the global-in-time existence of weak solutions and bounded weak solutions depending on some conditions of parameters such as chemotactic sensitivity and consumption rate of oxygen for certain range of diffusive exponents of cell density in two and three dimensions.

A Study on the Evaluation of Energy Consumption of the Air Compressor (공기압축기 소비에너지 평가에 관한 연구)

  • Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.17 no.2
    • /
    • pp.38-44
    • /
    • 2020
  • Various efforts have been initiated to reduce the energy consumption of the compressor as it is one of the approaches to saving a large portion of the fixed cost of the production site. Various results of reducing the energy consumption of the compressor have been reported, but to reduce the energy consumption of the compressors fundamentally, regular management of the compressor should ensure optimum operation. This requires periodic on-site visits by experts, but is often overlooked as a cost issue, resulting in the use of the compressor in low-efficiency conditions. Thus, it is necessary to develop a low-cost evaluation technology for compressor condition monitoring and efficiency analysis to ensure that the compressor is always driven at the optimum efficiency without imposing undue burden on the compressor user. In this study, a sensor was installed at the inlet, outlet, and power supply of the compressor, and a method for evaluating the energy consumption of the compressor using the minimum sensor was derived. The experimental results are presented to show the validity of the proposed method. It was confirmed that the energy consumption of the compressor can be easily as well as efficiently evaluated by using the method developed in this study.

Correlation of Coffee Consumption, Lifestyle, and Nutrient Density (커피 소비와 생활습관 및 영양밀도의 관련성)

  • Kim, Sun-Hee;Han, Byoung-Duck;Yun, Mi-Eun
    • Journal of the Korean Dietetic Association
    • /
    • v.25 no.2
    • /
    • pp.115-128
    • /
    • 2019
  • This study evaluated the nutrient intake with increasing coffee consumption for 403 adults aged over 30 years in Korea. The 403 subjects were national health screening examinees, who visited Sahmyook Seoul Hospital's Comprehensive Check-up Center between 2017.11.01 and 2018.12.18. The subjects were asked to answer questionnaires covering a 24-hour recall fluid and dietary intake before the health examination. The research ethics council of Sahmyook University (2-7001793-AB-N-012019036HR) approved this study. Coffee consumption exceeding two servings daily was more likely in males, in those aged between 30 and 40 years, and in the smoking, drinking, non-exercise, non-breakfast groups compared to each counterpart. The correlation between the coffee consumption frequency and current nutrient density showed negative correlations in most micronutrients. The mean nutrient density decreased gradually with increasing coffee consumption (<1 serving daily, ${\leq}1{\sim}2$ servings daily, >2 servings daily) in the ANOVA analysis. Therefore, the progressive adverse health effects of excessive coffee consumption needs to be researched further, and a daily total caffeine limit should be suggested in education of the nation levels.

Development of the steam ejector for vacuum system (진공 시스템용 스팀 이젝터 개발)

  • Choi, Seokho;Lee, Kyeongwoo;Chon, Muhwin;Paek, Minsu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.648-651
    • /
    • 2004
  • A vacuum system with ejector has been widely used because of its simple construction and easy maintenance. Ejectors are the main part of the vacuum system, of which designs determine the efficiency of vacuum system. The ejector with the capacity of 1.5 ton/hr steam consumption was designed and tested. The results showed that the tested values are satisfied with the designed specifications. Comparing with other ejectors designed by overseas specialist makers, it seems to have a good performance.

  • PDF

Size and Shape Optimization of the Oil Pump for Fuel Consuming Reduction (엔진 연비 향상을 위한 오일펌프 사이즈/형상 최적화)

  • Jo, Sok-Hyun;Nam, Kyung-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.22-28
    • /
    • 2008
  • Generally block imbedded type oil pump is adopted to make a small engine. In this paper 1D/3D numerical simulations were conducted to reduce energy consumption of the block imbedded type oil pump. At each stage of engine development we have estimated the oil flow rate and pressure to optimize oil pump sizes by using the 1D system analysis and then accomplished 3D CFD(Computational Fluid Dynamics) simulations to optimize oil pump shapes including inlet/outlet port. As a result, the energy consumption of oil pump has been reduced to nearly 27% and the engine fuel consumption to $1{\sim}1.5%$.

A Method of Estimation of Energy Consumption according to a Supply Pressure for Pneumatic Cylinder Driving Apparatus (공급압력 변화에 의한 공기압 실린더 구동장치의 소비에너지 변화량 추정 방법)

  • Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.15-20
    • /
    • 2012
  • Pneumatic cylinder meter-out driving apparatus is used widely because it is clean, lightweight, and can be easily serviced. In this study an estimation method of energy consumption for pneumatic cylinder meter-out driving apparatus is proposed. The proposed method is derived from state equation and energy equation of air, and, the equation of motion of a moving part of a pneumatic cylinder reflecting the characteristics of the meter-out driving. The effectiveness of the proposed method is proved by simulation study and it demonstrates that the proposed method can evaluate the energy consumption quickly and easily when the parameters of the driving apparatus are changed.

Development of a HDD Spindle Motor Using Passive Magnet Bearing and Fluid Dynamic Journal Bearing (수동형 자기 베어링과 유체 동압 저널베어링을 이용한 HDD용 스핀들 모터 개발)

  • Lee, Chung-Ill;Kim, Hak-Woon;Jang, Gun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.473-477
    • /
    • 2005
  • This paper presents a highly efficient HDD (Hard Disk Drive) spindle motor with a passive magnetic thrust bearing and a fluid dynamic journal bearing and its effectiveness is verified through experiment. It eliminates the mechanical friction loss of a thrust bearing which is around 18% of total power consumption of a 3.5' HDD spindle motor, by replacing a conventional fluid dynamic thrust bearing with a passive magnetic thrust bearing. The passive magnetic thrust bearing using permanent magnets is inherently unstable in radial direction. However, the radial fluid dynamic force of the fluid dynamic journal bearing counterbalances the radial magnetic force of magnetic thrust bearing to achieve the stability as the motor spins up. It has less or equivalent runout and less flying height than the conventional spindle motor.

  • PDF

Assessment of gas production and electrochemical factors for fracturing flow-back fluid treatment in Guangyuan oilfield

  • Liu, Yang;Chen, Wu;Zhang, Shanhui;Shi, Dongpo;Zhu, Mijia
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.521-528
    • /
    • 2019
  • Electrochemical method was used for the fracturing flow-back fluid treatment in Guangyuan oilfield. After performing electrolysis, we found that the amount of $H_2$ gas produced by electrode was closely related to the combination mode of electrodes and electrode materials. Using an aluminium electrode resulted in a large $H_2$ production of each electrode combination, whereas inert anode and cathode materials resulted in low $H_2$ production. Then, the relationship between the gas production of $H_2$ and the treatment efficiency of fracturing flow-back fluid in Guangyuan oilfield was studied. Results showed that the turbidity removal and decolourisation rates of fracturing flow-back fluid were high when $H_2$ production was high. If the $H_2$ production of inert electrode was large, the energy consumption of this inert electrode was also high. However, energy consumption when an aluminium anode material was used was lower than that when the inert electrode was used, whereas the corresponding electrode combination production of $H_2$ was larger than that of the inert electrode combination. When the inert electrode was used as anode, the gas production type was mainly $O_2$, and $Cl_2$ was also produced and dissolved in water to form $ClO^-$. $H_2$ production at the cathode was reduced because $ClO^-$ obtained electrons.

Energy Efficient Design of a Jet Pump by Ensemble of Surrogates and Evolutionary Approach

  • Husain, Afzal;Sonawat, Arihant;Mohan, Sarath;Samad, Abdus
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.3
    • /
    • pp.265-276
    • /
    • 2016
  • Energy systems working coherently in different conditions may not have a specific design which can provide optimal performance. A system working for a longer period at lower efficiency implies higher energy consumption. In this effort, a methodology demonstrated by a jet pump design and optimization via numerical modeling for fluid dynamics and implementation of an evolutionary algorithm for the optimization shows a reduction in computational costs. The jet pump inherently has a low efficiency because of improper mixing of primary and secondary fluids, and multiple momentum and energy transfer phenomena associated with it. The high fidelity solutions were obtained through a validated numerical model to construct an approximate function through surrogate analysis. Pareto-optimal solutions for two objective functions, i.e., secondary fluid pressure head and primary fluid pressure-drop, were generated through a multi-objective genetic algorithm. For the jet pump geometry, a design space of several design variables was discretized using the Latin hypercube sampling method for the optimization. The performance analysis of the surrogate models shows that the combined surrogates perform better than a single surrogate and the optimized jet pump shows a higher performance. The approach can be implemented in other energy systems to find a better design.

Factors Affecting Performance of a Proto type Windheat Generation System

  • Kim Y.J.;Yun J.H.;Ryou Y.S.;Kang G.C.;Paek Y.;Kang Y.K.
    • Agricultural and Biosystems Engineering
    • /
    • v.6 no.1
    • /
    • pp.22-26
    • /
    • 2005
  • A wind-heat generation system was developed and the system consisted of an electric motor, a heat generation drum, a heat exchanger, two circulation pumps and a water storage tank. The heat generation drum is an essential element determining performance of the system. Frictional heat was generated by rotation of a rotor in the drum filled with a working fluid, and the heat stored in the fluid was used to increase water temperature through the heat exchanger. Effects of some factors such as rotor shape, kind and amount of working fluid, rotor rpm and water flow rate in the heat exchanger, affecting the system performance were investigated. Amounts of heat generated were varied, ranging from 126,000 to 32,760 kJ/hr, depending on combination of the factors. Statistical analysis using GLM procedure revealed that the most influential factor to decide the system performance was amount of the fluid in the drum. Experiments showed that the faster the speed of the rotor, the greater heat was obtained. The greatest efficiency of the heat generation system, electric power consumption rate vs gained heat amount of water, was about 70%. Though the heat amount was not enough for plant bed heating of a 0.1-ha greenhouse, the system would be promising if some supplementary heat source such as air- water heat pump is added.

  • PDF