• 제목/요약/키워드: Fluid Management

검색결과 517건 처리시간 0.024초

해양플랜트 폭발사고 위험도 평가/관리를 위한 실증시험기법에 관한 연구 (A Research on the Verification Test Procedure for Quantitative Explosion Risk Assessment and Management of Offshore Installations)

  • 김봉주;하연철;서정관
    • 대한조선학회논문집
    • /
    • 제55권3호
    • /
    • pp.215-221
    • /
    • 2018
  • The structural design of offshore installations against explosions has been required to protect vital areas (e.g. control room, worker's area etc.) and minimize the damage from explosion accidents. Because the explosion accident will not only result in significant casualties and economic losses, but also cause serious pollution and damage to surrounding environment and coastal marine ecosystems. Over the past two decades, an incredible efforts was made to develop reliable methods to reduce and manage the explosion risk. Among the methods Quantitative Risk Assessment and Management (QRA&M) is the one of cutting-edge technologies. The explosion risk can be quantitatively assessed by the product of explosion frequency based on probability calculation and consequence analyzed using computer simulations, namely Computational Fluid Dynamics (CFD) and Finite Element Analysis (FEA). However to obtain reliable consequence analysis results by CFD and FEA, uncertainties associate with modeling and simulation are needed to be identified and validated by comparison with experimental data. Therefore, large-scaled explosion test procedure is developed in this study. And developed test procedure can be helpful to obtain precious test data for the validation of consequence analysis using computer simulations, and subsequently allow better assessment and management of explosion risks.

Management of Acute Gastroenteritis in Children: A Survey among Members of the Korean Society of Pediatric Gastroenterology, Hepatology, and Nutrition

  • Seo, Ji-Hyun;Shim, Jung Ok;Choe, Byung-Ho;Moon, Jin Su;Kang, Ki-Soo;Chung, Ju-Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제22권5호
    • /
    • pp.431-440
    • /
    • 2019
  • Purpose: No national survey has yet described the guidelines followed by Korean pediatricians to treat acute gastroenteritis (AGE). An online survey was performed to investigate the management of AGE followed by members of The Korean Society of Pediatric Gastroenterology, Hepatology, and Nutrition, and the results were compared between pediatric gastroenterologists (PG) and general pediatricians (GP). Methods: Questionnaires were sent to pediatricians between June 2 and 4, 2018 regarding the type of hospital, indications for admission, antiemetic and antidiarrheal drugs and antibiotics prescribed, and dietary changes advised. Results: Among the 400 pediatricians approached, 141 pediatricians (35.3%) responded to the survey. PG comprised 39% of the respondents and 72.7% worked at a tertiary hospital. Both PG and GP considered diarrhea or vomiting to be the primary symptom. The most common indication for hospitalization was severe dehydration (98.8%). Most pediatricians managed dehydration with intravenous fluid infusions (PG 98.2%, GP 92.9%). Antiemetics were prescribed by 87.3% of PG and 96.6% of GP. Probiotics to manage diarrhea were prescribed by 89.1% of PG and 100.0% of GP. Antibiotics were used in children with blood in diarrheal stool or high fever. Dietary changes were more commonly recommended by GP (59.3%) than by PG (27.3%) (p<0.05). Tests to identify etiological agents were performed primarily in hospitalized children. Conclusion: This survey assessing the management of pediatric AGE showed that the indications for admission and rehydration were similar between GP and PG. Drug prescriptions for diarrhea and dietary changes were slightly commonly recommended by GP than by PG.

Survey of research on the optimal design of sea harbours

  • Diab, Hassan;Younes, Rafic;Lafon, Pascal
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권4호
    • /
    • pp.460-472
    • /
    • 2017
  • The design of harbours, as with any other system design, must be an optimization process. In this study, a global examination of the different constraints in coastal engineering was performed and an optimization problem was defined. The problem has multiple objectives, and the criteria to be minimized are the structure cost and wave height disturbance inside a harbour. As concluded in this survey, the constraints are predefined parameters, mandatory constraints or optional constraints. All of these constraints are categorized into four categories: environmental, fluid mechanical, structural and manoeuvring.

심장 파열 수술치험 10례에 대한 분석 (Cardiac Rupture Clinical Analysis of 10 -Operative Cases-)

  • 손영상;최영호;김학제
    • Journal of Chest Surgery
    • /
    • 제28권11호
    • /
    • pp.1001-1006
    • /
    • 1995
  • From January, 1990 to December, 1994, we have operated 10 patients with cardiac rupture. The patients are divided into two groups according to their clinical manifestation ; five patients in each hemorrhage and tamponade group. The patients in both groups could maintain their vital signs with closed thoracostomy and fluid resuscitation. The effect of pericardiocentesis was especially dramatic in three patients of tamponade group. The average time from injury to admission was 101 minutes and that of the patients who came our hospital via one or two other hospitals was 170 minutes comparing 31 minutes of those who came directly. The average time from admission to operation was 211 minutes. Considering 98 minutes for the diagnosis and preoperative management and another 30 minutes for the preparation for operation, operations were delayed by 83 minutes to get permission. We conclude that this delaying time for transport and operation of heart-ruptured patients should be shortened in order to manage them more effectively.

  • PDF

자발성 두개내 저압환자에서 경막외 혈액봉합술로 치험한 3예 (Three Cases of Spontaneous Intracranial Hypotension(SIH) Treated with Epidural Blood Patch)

  • 신진우;윤창섭;이청
    • The Korean Journal of Pain
    • /
    • 제10권1호
    • /
    • pp.104-108
    • /
    • 1997
  • Spontaneous intracranial hypotension, a syndrome of low CSF pressure, occurs without preceding events such as lumbar puncture, back trauma, operative procedure or medical illness. The most characteristic symptom is an occipital or frontal headache which is aggrevated in the erect position and relieved in the supine position. This syndrome usually resolves spontaneously or with strict bed rest. When the headach persists or is incapacitating, more aggressive treatment may be necessary. Autologous epidural blood patch is highly effective in the management of spontaneous intracranial hypotension. Epidural blood produces an organized clot which effectively tamponade any dural CSF leak. The rapid relief of headache immediately after the infusion of blood occur by some other mechanism, such as an increase in subarachnoid pressure that is known to occur with infusion of fluid into the lumbar epidural space. We report three cases of spontaneous intracranial hypotension successfully treated with epidural blood patch.

  • PDF

시판된장의 리올로지(Rheology) 특성에 관한 연구 (Flow Properties of Doenjang)

  • 양신철;김선화
    • 한국관광식음료학회지:관광식음료경영연구
    • /
    • 제13권1호
    • /
    • pp.55-68
    • /
    • 2002
  • Flow properties of doenjang samples at various total solid contents (30, 32, 34, 36, 38, 40%) were evaluated in this study. Flow properties of doenjang samples was determined by using Haake concentric cylinderical viscometer and Instron testing machine with capillary extrusion viscometer, and consistency index(K), and flow behavior index(n) was also determined from power models, and yield stress was derived form Casson models and vanes methods. Doenjang samples showed shear-thinning (pseudoplastic) fluid with small magnitude of flow behavior index(n) (n=0.30-0.55). Casson yield stress was from 2.11 to 64.02(Pa). Vane yield stress was more effective than casson yield stress in property of reactivation. Apparent viscosity was decreased with the increase in temperature and activation energy was in the range of 6.58 to 10.70 kJ/mole. From the capillary extrusion method, K and n was increased with the increase in solid content with good correlation with. The result revealed that capillary extrusion method is useful for measuring the flow properties of doenjang.

  • PDF

New Paradigm of Systems Thinking and Action in an Interior Design Education Field

  • Choi, Seung-Pok
    • International Journal of Contents
    • /
    • 제7권1호
    • /
    • pp.52-57
    • /
    • 2011
  • The organizational theory and design in future encourages us to bring a fluid perspective to the problems and challenges face. Organizational structure, strategy, management style, teamwork, organizational change, and even products and services can be vitalized and re-formed through creative images that allow us to act in new ways. Leaders and educators sat all levels must gain comfort in dealing with the insights and implications of diverse perspectives. In a leadership paradigm in action, leaders and educators who have more flexibility and willingness to create a learning organization are successful in improving productivity and student empowerment. The key element to organizational structure and changes for interior design education becomes communications. Finally, we need to recognize that despite its roots in mechanistic thinking, organization is a creative process of imagination. We organize as we imagine, and it is always possible to imagine in new ways.

Gas-Forming Brain Abscess Caused by Klebsiella Pneumoniae

  • Cho, Keun-Tae;Park, Bong-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권6호
    • /
    • pp.382-384
    • /
    • 2008
  • Gas forming brain abscess is a rare disease caused by Klebsiella pneumoniae occurring in patients with impaired host defense mechanism such as diabetes mellitus or liver cirrhosis. A 59-year-old man with 2-year history of diabetes mellitus and 20-year history of liver cirrhosis presented to the hospital with headache. On the day after admission, severe headache was developed and he deteriorated rapidly. Brain CT showed a non-enhanced mass including multiple air density as well as surrounding edema seen in the right occipital lobe, and isodensity air-fluid level seen in the right lateral ventricle. Despite emergent ventricular drainage and intraventricular and intravenous administration of antibiotics, his condition progressively worsened to sepsis and to death after 5 days. Bacterial culture of blood and ventricular fluids disclosed a Gram (-) rod, Klebsiella pneumoniae. In this report we review the pathogenic mechanism and its management.

Diffuse Pneumocephalus : A Rare Complication of Spinal Surgery

  • Yun, Jung-Ho;Kim, Young-Jin;Yoo, Dong-Soo;Ko, Jung-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권3호
    • /
    • pp.288-290
    • /
    • 2010
  • The common etiologies of pneumocephalus, presence of air in the intracranial cavity, are trauma and cranial surgery. Pneumocephalus after spinal surgery is an unusual postoperative complication. We report the case of a male 59-year-old man who developed a pneumacephalus after posterior lumbar surgery for spinal stenosis. Intraoperatively, a cerebrospinal fluid leak following a dural tear was noted and immediately repaired. The next day, the patient complained of headache and dizziness. Head and lumbar computed tomography scans revealed significant air in the frontal region, several cisterns, intraventricle, and extra-dural area in the spine canal. Symptoms were spontaneously resolved within 2 weeks with conservative management.

Axisymmetric dynamic instability of polar orthotropic sandwich annular plate with ER damping treatment

  • Yeh, Jia-Yi
    • Smart Structures and Systems
    • /
    • 제13권1호
    • /
    • pp.25-39
    • /
    • 2014
  • The axisymmetric dynamic instability of polar orthotropic sandwich annular plate combined with electrorheological (ER) fluid core layer and constraining layer are studied in this paper. And, the ER core layer and constraining layer are used to improve the stability of the annular plate system. The boundaries of instability regions for the polar orthotropic sandwich annular plate system are obtained by discrete layer annular finite element and the harmonic balance method. The rheological property of an electrorheological material, such as viscosity, plasticity, and elasticity can be controlled by applying different electric field strength. Thus, the damping characteristics of the sandwich system are more effective when the electric field is applied on the sandwich structure. Additionally, variations of the instability regions for the polar orthotropic sandwich annular plate with different applying electric field strength, thickness of ER layer and some designed parameters are investigated and discussed in this study.