• 제목/요약/키워드: Flue Gas

검색결과 606건 처리시간 0.025초

배연탈질설비의 성능향상을 휘한 가스혼합에 관한 연구 (A Study on the Flue Gas Mixing for the Performance Improvement of De-NOx plant)

  • 류병남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.462-472
    • /
    • 1999
  • De-NOx facility using Selective Catalytic Reduction method is the most widely applied one that removes NOx from flue gas emitted from combustion facility such as boiler for power generation engine incinerator etc. Reductant $NH_3\;or\;NH_4OH$ is sprayed into flue gas to convert NOx into $H_2O$ and $N_2.$ Good mixing between flue gas and $NH_3$ is the most important factor to increase reduction in catalytic layer and to reduce unreacted NH3 slip. Therefore the development of mixer device for mixing effect is one of the important part for SCR facility. Objectives of this study are to investigate the relation between flow and concentration field by observation at the wake of delta-wing type mixer. At the first stage qualitative measurement of flow field is conducted by flow visualization using laser light sheet in lab. scale wind tunnel. Also we have conducted the quantitative analysis by comparing flow field measurement using LDV with numerical simulation. On the basis of qualitative and quantitative analysis we investigate the dis-tribution of flow and concentration in flow model facility. The results of an experimental and compu-tational examination of the vortex structures shed from delta wing type vortex generator having $40^{\circ}$ angle of attack are presented, The effects of vortex structure on the gas mixing is discussed, too.

  • PDF

소각로에서의 연소가스 체류시간 (The residence time of gas in an incinerator)

  • 김성준
    • 산업기술연구
    • /
    • 제36권
    • /
    • pp.3-7
    • /
    • 2016
  • The change of flue gas residence time with the location of air inlet in an incinerator is analysed. An independent numerical variable is the location of air inlet and dependant is the residence time of flue gas. The mean value of turbulence energy in a primary combustion chamber is also analysed. The flow field and the distribution of turbulence energy are investigated to evaluate their influence on the residence time of flue gas and the turbulence energy. As the position of secondary air inlet approaches to the top of primary combustion chamber, the residence time of gas and the turbulence energy become longer and larger respectively.

  • PDF

산업용 보일러의 배연탈황 및 탈질에 관한 연구 (A Study on Desulfurization and Denitrification of Flue Gas in Industry Boiler)

  • 이태호;정순형;정흥기
    • 환경위생공학
    • /
    • 제10권3호
    • /
    • pp.99-104
    • /
    • 1995
  • The objective of this study was to investigate the effect on denuclearization and decertification of flue gas by utilizing Mg( OH)$_{2}$ and NaOH as reagents in industrial boiler. We used packed absorber with Tellerette in all cases. And pH of circulation solution, rate of liquid per gas in absorber, COD concentration by pH variation in oxidation basin were inves- tigated. The following conclusions were obtained from experimental results: 1. Concerning running cost for reagents, Mg( OH)$_{2}$ reagent for treatment of flue gas was more economical than NaOH. 2. While Mg( OH )$_{2}$ and NaOH as absorbents were used, then the ratio of denuclearization was 96 and 97% respectively and nitrification was recorded 29 and 25% . 3. In this absorption tests the optimum condition for ratio of liquid per gas, pH and nonregenerable salt concentration of circulation solution were 3.6ℓ /Nm$^{3}$, 6.0, 0.5∼1.0% respectively, 4. Initial COD in oxidation basin was 800 ∼ 1,00099ut after adjusting to pH 7.0, COD of effluent water was less than 20ppm.

  • PDF

가스난방용 적외선 히터의 연소배기가스 특성해석 (Analysis of the Characteristics of Flue Gas in Infrared Mobile Heaters for Gas Room Heating)

  • 김영규;권정락;김청균
    • 한국가스학회지
    • /
    • 제2권1호
    • /
    • pp.66-73
    • /
    • 1998
  • 본 연구에서는 부탄가스를 연료로 사용하고 있는 이동식 적외선 가스히터의 연소시 배출되는 배기가스의 농도수준과 특성을 분석하였다. 실험은 연소 챔버의 크기와 챔버의 온도를 고려하여 실험을 수행하였다. 산소결핍 안전장치가 작동하는 $O_2$의 농도는 챔버의 내용적에 관계없이 $18.3\%$로 각각 나타났고, 작동하는 시간은 내용적이 클수록 늦게 작동하였다. 밀폐공간에서 연소시 $O_2$$CO_2$는 선형성을 가지며, CO농도는 $O_2$$CO_2$의 발생수준과는 관계없이 연소가 시작된 10분 이후부터 그 발생폭이 불규칙적으로 크게 나타났다. 이들 결과는 가스 난방기를 실내에서 사용할 때 충분한 환기를 통하여 불안전 연소를 방지하고 $O_2$ 감소에 따른 질식사고와 CO에 의한 중독사고를 예방할 수 있다는 측면에서 대단히 중요하다.

  • PDF

하이드로퀴논 크러스레이트를 이용한 배가스 분리 특성 연구 (Study on Separation Characteristics of Flue Gas Using Hydroquinone Clathrate Compounds)

  • 이종원;최기종
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.865-868
    • /
    • 2011
  • 배가스로부터 이산화탄소의 분리 특성을 파악하기 위해 유기 화합물인 하이드로퀴논을 이용하여 크러스레이트 화합물을 형성하였다. 형성된 크러스레이트 화합물은 고체 NMR 및 라만 분광법을 이용하여 기체의 포집 거동을 확인하였으며, 기체 분리 효율을 계산하기 위하여 원소 분석기를 통한 정량분석도 함께 수행하였다. 분석 결과 배가스에 포함된 이산화탄소는 질소에 비해 동일한 조건에서 크러스레이트 화합물 내로 더 잘 포집되는 것으로 확인되었다. 또한 다양한 압력에서 형성된 시료들을 분석한 결과, 이러한 이산화탄소의 선택적 포집 특성이 매우 낮은 압력에서도 뚜렷한 것으로 확인되어 추가적인 에너지 소모를 적게 하면서도 배가스로부터 이산화탄소를 대규모로 분리/회수하는 것이 가능할 것이라 판단된다. 본 연구에서 얻어진 결과는 향후 배가스에 대한 분리 응용 기술이나 혼합 가스의 선택적 분리와 같은 분야에서 중요한 정보를 제공할 수 있을 것으로 기대된다.

보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법 (Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers)

  • 정재진;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

2차 공기 주입 조건 변화에 따른 소형 소각로 내부의 유동장 분석 (Analysis of the Gas Flow Field of Primary Combustion Chamber with the Conditions of Secondary Air Injection)

  • 최병대;김성준
    • 산업기술연구
    • /
    • 제22권A호
    • /
    • pp.9-17
    • /
    • 2002
  • This analysis is aimed to find out how the conditions of secondary air injection affects the residence time and the turbulence energy of flue gas and flow field in a small incinerator. A commercial code, PHOENICS, is used to simulate the flow field of an Incinerator. The computational grid system is constructed in a cartesian coordinate system In this numerical experiment, an independent numerical variable is the conditions of secondary air injection and dependants are the residence time of flue gas and the mean value of turbulence energy in a primary combustion chamber. The flow field and the distribution of turbulence energy are analysed to evaluate the residence time of flue gas and the turbulence energy The computational results say that the tangential injection of secondary air make the residence time much longer than the radial injection and that the radial injection of secondary make turbulence much stronger than the tangential injection.

  • PDF

덕트 유동에서 증발을 수반하는 액상 스프레이의 혼합 특성에 대한 실험적 연구 (An experimental study on the mixing of evaporating liquid spray in a duct flow)

  • 김영봉;최상민
    • 한국분무공학회지
    • /
    • 제11권1호
    • /
    • pp.30-38
    • /
    • 2006
  • High temperature furnaces such as power plant and incinerator contribute considerable part of NOx generation and face urgent demand of De-NOx system. Reducing agent is injected into the flue gas flow to activate do-NOx system. Almost SCR system adopt vaporized ammonia injection system. Vaporizer, dilution system and additional space are needed to gasify and inject ammonia. Liquid spray injection system can simplify and economize post-treatment system of flue gas. In this study, mixing caused by gas or liquid injection of reducing agent into flue gas duct was investigated experimentally. Carbonated water was used as tracer and simulated agent and mixing of liquid spray in a duct flow was studied. To achieve that, the angle of attack of static mixer is simulated and $CO_2$ concentration is measured.

  • PDF

모드해석을 이용한 플루가스 냉각기의 진동 저감 방법에 관한 연구 (A Study on the Vibration Reduction of Flue Gas Cooler Using Modal Analysis)

  • 이부윤;김원진
    • 한국정밀공학회지
    • /
    • 제29권6호
    • /
    • pp.664-670
    • /
    • 2012
  • In this work, vibration characteristics of a flue gas cooler(FGC) for a heavy oil upgrading are experimentally analyzed and an effective method is proposed to reduce the vibration level. Firstly, the vibration under the operation condition of the FGC is measured and analyzed to identify the generation phenomena of vibration. And the displacement of the outer wall of the FGC is also analyzed to identify dominant frequencies of vibration. Secondly, an effective design to reduce the vibration is suggested by using the modal analysis. Consequently an improved design of the FGC gas cooler, which has lower vibration level, is obtained and then verified though the analysis and test.

NO Reduction and Oxidation over PAN based-ACF

  • Kim, Je-Young;Lee, Jong-Gyu;Hong, Ik-Pyo
    • Carbon letters
    • /
    • 제1권1호
    • /
    • pp.17-21
    • /
    • 2000
  • Catalytic reduction and oxidation of NO over polyacrylonitrile based activated carbon fibers (PAN-ACF) under various conditions were carried out to develop removal process of NO from the flue gas. The effect of temperature, oxygen concentration and the moisture content for the reduction of NO with ammonia as a reducing agent was investigated. The reduction of NO increased with the oxygen concentration, but decreased with the increased temperature. The moisture content in the flue gas affects the reduction of NO as the inhibition of the adsorption of the other components and the reaction on the surface of ACE For the oxidation of NO to $NO_2$ over PAN-ACF without using a reducing gas, it showed the temperature and the oxygen concentration of the flue gas are the important factors for the NO conversion in which the conversion increased with oxygen concentration and decreased with the temperature increase and might be the alternative option for the selective catalytic reduction process.

  • PDF