A Study on the Vibration Reduction of Flue Gas Cooler Using Modal Analysis

모드해석을 이용한 플루가스 냉각기의 진동 저감 방법에 관한 연구

  • Lee, Boo-Youn (Department of Mechanical & Automotive Engineering, Keimyung Univ.) ;
  • Kim, Won-Jin (Department of Mechanical & Automotive Engineering, Keimyung Univ.)
  • 이부윤 (계명대학교 기계자동차공학과) ;
  • 김원진 (계명대학교 기계자동차공학과)
  • Received : 2011.08.26
  • Accepted : 2012.03.12
  • Published : 2012.06.01

Abstract

In this work, vibration characteristics of a flue gas cooler(FGC) for a heavy oil upgrading are experimentally analyzed and an effective method is proposed to reduce the vibration level. Firstly, the vibration under the operation condition of the FGC is measured and analyzed to identify the generation phenomena of vibration. And the displacement of the outer wall of the FGC is also analyzed to identify dominant frequencies of vibration. Secondly, an effective design to reduce the vibration is suggested by using the modal analysis. Consequently an improved design of the FGC gas cooler, which has lower vibration level, is obtained and then verified though the analysis and test.

Keywords

References

  1. Bae, Y. C., Kim, H. S., Lee, W. R., Lee, D. Y., and Kim, B. S., "Vibration Analysis and Reduction for Large-scale Diesel Engines," Transactions of the Korean Society of Mechanical Engineers B, Vol. 35, No. 10, pp. 1047-1052, 2011. https://doi.org/10.3795/KSME-B.2011.35.10.1047
  2. Ryu, S. J. and Ha, H. C., "Modal Analysis and Testing of a High Head Pump/Turbine Runner," Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 8, No. 6, pp. 1062-1068, 1998.
  3. Shin, I. H., Song, W. P., and Kweon, K. Y., "The Normal Mode Analysis of 800kV Gas Insulated Switchgear(GIS) for the Dangjin Thermal Plant," Proceedings of KIEE Annual Summer Conference, pp. 363-365, 1999.
  4. ASME, "ASME Boiler & Pressure Vessel Code, Section II Part D," 2007.
  5. ANSYS Inc., "ANSYS User's Manual," 2010.