Analysis of the Characteristics of Flue Gas in Infrared Mobile Heaters for Gas Room Heating

가스난방용 적외선 히터의 연소배기가스 특성해석

  • 김영규 (한국가스안전공사 가스안전기술연구센터) ;
  • 권정락 (한국가스안전공사 가스안전기술연구센터) ;
  • 김청균 (홍익대학교 기계공학과)
  • Published : 1998.03.01

Abstract

This paper deals with the combustion characteristics of flue gas in infared mobile heaters. The experimental work has been performed to obtain the concentration levels and combustion characteristics of flue gas with varying chamber size and room temperature. The experimental results showed that oxygen depletion sensor device was operated at the oxygen concentration level of $18.3\%$ for all the chamber size. The combustion characteristics of oxygen and carbon dioxide show a linearity After 10 minutes the combustion property of carbon monoxide occurs at random without a level of oxygen and carbon dioxide in closed space of the heater. In these results, it is very important to prevent incomplete combustion through a sufficient ventilation, and accident prevention with a reduction of the oxygen and diffusion of toxic carbon monoxide.

본 연구에서는 부탄가스를 연료로 사용하고 있는 이동식 적외선 가스히터의 연소시 배출되는 배기가스의 농도수준과 특성을 분석하였다. 실험은 연소 챔버의 크기와 챔버의 온도를 고려하여 실험을 수행하였다. 산소결핍 안전장치가 작동하는 $O_2$의 농도는 챔버의 내용적에 관계없이 $18.3\%$로 각각 나타났고, 작동하는 시간은 내용적이 클수록 늦게 작동하였다. 밀폐공간에서 연소시 $O_2$$CO_2$는 선형성을 가지며, CO농도는 $O_2$$CO_2$의 발생수준과는 관계없이 연소가 시작된 10분 이후부터 그 발생폭이 불규칙적으로 크게 나타났다. 이들 결과는 가스 난방기를 실내에서 사용할 때 충분한 환기를 통하여 불안전 연소를 방지하고 $O_2$ 감소에 따른 질식사고와 CO에 의한 중독사고를 예방할 수 있다는 측면에서 대단히 중요하다.

Keywords