• 제목/요약/키워드: Flow level

검색결과 4,348건 처리시간 0.029초

간호대학생의 그릿과 학습몰입과의 관계에서 낙관성의 매개효과 (The mediating effect of optimism between grit and learning flow of nursing students)

  • 김영숙;이경숙
    • 한국간호교육학회지
    • /
    • 제27권2호
    • /
    • pp.144-151
    • /
    • 2021
  • Purpose: The purpose of this study was to investigate the mediating effect of optimism on the relationship between grit and learning flow in nursing college students. Methods: Structured self-reported questionnaires were used to measure grit, optimism and learning flow. The study was conducted on 200 nursing students in P, U and J cities between September 1 and September 20, 2020. The data were analyzed using a t-test, one-way ANOVA, Pearson's correlation coefficients and hierarchical multiple linear regression with SPSS/WIN 23.0. Results: Significant relationships were found between learning flow and grit (r=.60, p<.001), between learning flow and optimism (r=.42, p<.001), and between grit and optimism (r=.42, p<.001). Additionally, optimism had a partial mediating effect on the relationship between grit and learning flow (Z=3.11, p<.001). Conclusion: These results indicate that interventions to increase the level of grit along with optimism is necessary in order to increase the level of nursing college students' learning flow.

SOME MECHANICAL FACTORS AFFECTING MACHINE MILKING CHARACTERISTICS UNDER SEMI-ARID CONDITION

  • Ali, A.K.A.;Farah, D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권3호
    • /
    • pp.475-480
    • /
    • 1992
  • The effect of mechanical factors and season of the year on milking characteristics (milk yield, time of milking, rate of milk flow, stripping time and tripping milk) were studied on 26 Holstein Friesian cows, raised under Saudi Arabia environmental conditions. Cows were in the third and fourth lactation and reached the peak. Cows milked twice a day with equal intervals. Three vacuum levels (34, 38 and 42 cfm) and two pulsation ratios were used to form six vacuum-pulsation combinations. The study was carried during two seasons Autumn-Winter (S1) and Spring-Summer (S2). After absorbing the cow equations least square analysis was used to analyze the data. Vacuum level 38 cfm and pulsation ratio 70:30 was the best among all combinations of vacuum level-pulsation ratio. No significant effect (p < .01) for season, up to the seventh half minute, on the rate of milk flow. However, season of the year has a significant effect on total milk yield, stripping time and stripping milk.

슬릿젯의 유동 및 냉각 성능에 대한 수치적 연구 (NUMERICAL ANALYSIS OF FLOW AND COOLING CHARACTERISTICS OF SLIT JETS IMPINGEMENT)

  • 손상일;손기헌;이필종;시성규
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.448-450
    • /
    • 2010
  • Free surface liquid jet impingement, which is applicable to cooling of hot plates in a steel-making process, is investigated numerically by solving the conservation equations of mass, momentum and energy in the liquid and gas phases. The free-surface of liquid-gas interface is tracked by an improved level-set method incorporating a sharp-interface technique for accurate imposition of stress and heat flux conditions on the liquid-gas interface. The level-set approach is combined with a non-equilibrium $k-{\omega}$ turbulence model. The computations are made for slit nozzle jets to investigate their flow and cooling characteristics. Also, the effects of jetting angle, velocity and moving velocity of plate on the interfacial motion and the associated flow and temperature fields are quantified.

  • PDF

수직관에서 상승하는 Taylor 기포의 수치해석 (Numerical Simulation of a Taylor Bubble Rising in a Vertical Tube)

  • 손기헌
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.373-380
    • /
    • 2001
  • In this study, a single Taylor bubble and a train of Taylor bubbles rising in a vertical tube were simulated numerically. A finite difference method was used to solve the mass and momentum equations for the liquid-gas region. The liquid-gas interface was captured by a level set function which is defined a signed distance from the interface. For a train of Taylor bubbles repeated periodically in space, the periodic conditions were imposed at the boundaries normal to the gravitational direction and the pressure boundary conditions were iteratively determined so that the computed flow rate should be equal to a given flow rate. Based on the numerical simulation, the calculated shape and rise velocity of a Taylor bubble were found to be in good agreement with the experimental data reported in the literature.

이동하는 평판에서 충돌제트의 유동 및 냉각 특성에 대한 수치적 연구 (A Numerical Study on Flow and Cooling Characteristics of Impinging Jets on a Moving Plate)

  • 전진호;서영호;손기헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2562-2567
    • /
    • 2008
  • Jet impingement on a moving plate, which is applicable to cooling of hot metals in a steel-making process, is investigated numerically by solving the Navier-Stokes equations in the liquid and gas phases. The liquid-gas interface or free surface is tracked by a level-set method which is improved by incorporating the ghost fluid approach based on a sharp-interface representation. The computations are made for multiple jets as well as a single jet to compare their flow characteristics. Also, the effects of the nozzle pitch, moving velocity of plate and jet velocity on the interfacial motion and the associated flow and temperature fields.

  • PDF

지반의 투수성에 따른 제체 침투류의 변화 (Variation of Seepage Line through Embankments by Permeability of Layer)

  • 신진환;이봉직
    • 한국안전학회지
    • /
    • 제11권2호
    • /
    • pp.109-115
    • /
    • 1996
  • The movement of water through a river embankment and its influenced upon the stability of the slope of the embankment are described. The stability of the embankment is depended upon the location of seepage line. As the seepage flow occurs in the embankment, the slope of the embankment loses its stability. Of particular interest is the stability following a rapid change of water level. The variation of seepage line in the embankment model by a fluctuation of water level is discussed. The experimental models were construction with slopes of 1 : 1.5, 1 : 2.0, 1 : 2.5 and the flow velocity was turned from 60cm/sec~90cm/sec. Based on the experimental study, the following conclusions are drawn. 1) When water level is raised, the seepage line of downstream slope Is raised rapidly as flow velocity increases. 2) For the case of permeable layer, the seepage line raised rapidly as compare with impermeable layer when water lever is raised.

  • PDF

단위유량도와 비수갑문 단면 및 방조제 축조곡선 결정을 위한 조속계산 (Calculation of Unit Hydrograph from Discharge Curve, Determination of Sluice Dimension and Tidal Computation for Determination of the Closure curve)

  • 최귀열
    • 한국농공학회지
    • /
    • 제7권1호
    • /
    • pp.861-876
    • /
    • 1965
  • During my stay in the Netherlands, I have studied the following, primarily in relation to the Mokpo Yong-san project which had been studied by the NEDECO for a feasibility report. 1. Unit hydrograph at Naju There are many ways to make unit hydrograph, but I want explain here to make unit hydrograph from the- actual run of curve at Naju. A discharge curve made from one rain storm depends on rainfall intensity per houre After finriing hydrograph every two hours, we will get two-hour unit hydrograph to devide each ordinate of the two-hour hydrograph by the rainfall intensity. I have used one storm from June 24 to June 26, 1963, recording a rainfall intensity of average 9. 4 mm per hour for 12 hours. If several rain gage stations had already been established in the catchment area. above Naju prior to this storm, I could have gathered accurate data on rainfall intensity throughout the catchment area. As it was, I used I the automatic rain gage record of the Mokpo I moteorological station to determine the rainfall lntensity. In order. to develop the unit ~Ydrograph at Naju, I subtracted the basic flow from the total runoff flow. I also tried to keed the difference between the calculated discharge amount and the measured discharge less than 1O~ The discharge period. of an unit graph depends on the length of the catchment area. 2. Determination of sluice dimension Acoording to principles of design presently used in our country, a one-day storm with a frequency of 20 years must be discharged in 8 hours. These design criteria are not adequate, and several dams have washed out in the past years. The design of the spillway and sluice dimensions must be based on the maximun peak discharge flowing into the reservoir to avoid crop and structure damages. The total flow into the reservoir is the summation of flow described by the Mokpo hydrograph, the basic flow from all the catchment areas and the rainfall on the reservoir area. To calculate the amount of water discharged through the sluiceCper half hour), the average head during that interval must be known. This can be calculated from the known water level outside the sluiceCdetermined by the tide) and from an estimated water level inside the reservoir at the end of each time interval. The total amount of water discharged through the sluice can be calculated from this average head, the time interval and the cross-sectional area of' the sluice. From the inflow into the .reservoir and the outflow through the sluice gates I calculated the change in the volume of water stored in the reservoir at half-hour intervals. From the stored volume of water and the known storage capacity of the reservoir, I was able to calculate the water level in the reservoir. The Calculated water level in the reservoir must be the same as the estimated water level. Mean stand tide will be adequate to use for determining the sluice dimension because spring tide is worse case and neap tide is best condition for the I result of the calculatio 3. Tidal computation for determination of the closure curve. During the construction of a dam, whether by building up of a succession of horizontael layers or by building in from both sides, the velocity of the water flowinii through the closing gapwill increase, because of the gradual decrease in the cross sectional area of the gap. 1 calculated the . velocities in the closing gap during flood and ebb for the first mentioned method of construction until the cross-sectional area has been reduced to about 25% of the original area, the change in tidal movement within the reservoir being negligible. Up to that point, the increase of the velocity is more or less hyperbolic. During the closing of the last 25 % of the gap, less water can flow out of the reservoir. This causes a rise of the mean water level of the reservoir. The difference in hydraulic head is then no longer negligible and must be taken into account. When, during the course of construction. the submerged weir become a free weir the critical flow occurs. The critical flow is that point, during either ebb or flood, at which the velocity reaches a maximum. When the dam is raised further. the velocity decreases because of the decrease\ulcorner in the height of the water above the weir. The calculation of the currents and velocities for a stage in the closure of the final gap is done in the following manner; Using an average tide with a neglible daily quantity, I estimated the water level on the pustream side of. the dam (inner water level). I determined the current through the gap for each hour by multiplying the storage area by the increment of the rise in water level. The velocity at a given moment can be determined from the calcalated current in m3/sec, and the cross-sectional area at that moment. At the same time from the difference between inner water level and tidal level (outer water level) the velocity can be calculated with the formula $h= \frac{V^2}{2g}$ and must be equal to the velocity detertnined from the current. If there is a difference in velocity, a new estimate of the inner water level must be made and entire procedure should be repeated. When the higher water level is equal to or more than 2/3 times the difference between the lower water level and the crest of the dam, we speak of a "free weir." The flow over the weir is then dependent upon the higher water level and not on the difference between high and low water levels. When the weir is "submerged", that is, the higher water level is less than 2/3 times the difference between the lower water and the crest of the dam, the difference between the high and low levels being decisive. The free weir normally occurs first during ebb, and is due to. the fact that mean level in the estuary is higher than the mean level of . the tide in building dams with barges the maximum velocity in the closing gap may not be more than 3m/sec. As the maximum velocities are higher than this limit we must use other construction methods in closing the gap. This can be done by dump-cars from each side or by using a cable way.e or by using a cable way.

  • PDF

구취발생과 구강환경의 연관성에 관한 연구 (A Study on the Relationship between Halitosis Developments and Oral Environmental)

  • 지윤정;김정술;이정화;전은숙
    • 치위생과학회지
    • /
    • 제10권2호
    • /
    • pp.101-107
    • /
    • 2010
  • 본 연구는 구취의 원인을 분류하고, 각 성분들에 영향을 미치는 구강환경 요인들과 어떤 관련성이 있는지를 조사하여 구취환자 개개인의 구강건강을 증진시키고 구취관련의 올바른 보건교육에 활용하고자 실시하였으며, 2009년 3월 1일부터 2010년 3월 1일까지 1년간 대도시 소재 치과병원 외래환자 98명의 자료를 최종분석에 이용한 결과 다음과 같은 결론을 얻었다. 1. 구취의 각 성분인 Hydrogen sulfide, Methyl mercaptan, Dimethyl sulfide 및 Ammonia의 평균 수치는 Hydrogen sulfide 36.71 ppb, Methyl mercaptan은 31.46 ppb, Dimethyl sulfide는 54.33 ppb, Ammonia는 22.60 ppm로 나타났고, 정상과 역치 이상의 검출비교 결과 Dimethyl sulfide는 46.9%가 역치 이상으로 검출되었고, Ammonia는 연구대상자 중 52%가 역치 이상으로 검출되어 가장 높게 나타났다. 2. Hydrogen sulfide 성분의 양에 따라 Dimethyl sulfide 성분의 양, 설태의 양과 타액 분비율이 통계적으로 유의한 관계가 있는 것으로 나타났다(p<0.05). 3. Methyl mercaptan 성분의 양은 Dimethyl sulfide의 성분과 설태량, 타액 분비율과 통계적으로 유의한 관계가 있었다(p<0.05). 4. Dimethyl sulfide성분의 양은 Hydrogen sulfide성분, Ammonia성분과 관련이 있었으며, 설태의 양, 타액분비율, 타액내 수소이온농도지수와도 관계가 있었다(p<0.05). 5. Ammonia성분은 Methyl mercaptan성분과 Dimethyl sulfide성분, 치주필요지수(CPI), 타액 분비율이 통계적으로 유의한 관계가 있었다(p<0.05).

청계천 실시간 홍수예보를 위한 Flow Nomograph 개발 및 평가 (Development and Assessment of Flow Nomograph for the Real-time Flood Forecasting in Cheonggye Stream)

  • 배덕효;심재범;윤성심
    • 한국수자원학회논문집
    • /
    • 제45권11호
    • /
    • pp.1107-1119
    • /
    • 2012
  • 본 연구의 목적은 도시하천으로 복원된 청계천유역의 실시간 홍수예보를 위한 flow nomograph를 개발하고, 실측자료를 통해 flow nomograph의 적용성을 검토하는데 있다. 본 연구의 적용대상 지역인 청계천 유역은 높은 불투수율, 짧은 도달시간 및 복잡한 수문학적 특성을 갖고 있어 기존 강우-유출 모형에 의한 홍수예측 방법의 선행시간 확보 측면에서 실효성을 거두지 못하고 있는 실정이다. 이에 본 연구에서는 홍수예보 선행시간을 확보하기 위해 강우정보만으로도 홍수예보가 가능한 flow nomograph를 개발하였다. Flow nomograph는 강우강도, 강우지속시간 등의 강우변수와 유량, 수위간의 상관관계를 구한 것이다. 본 연구에서는 Flow nomograph 개발과정에서 예보 기준 설정을 위해 홍수예보 지점을 선정하여 지점별 기준 홍수위를 산정하였으며, 다양한 홍수사상을 반영하기 위해 가상 강우시나리오를 설정하여 강우조건별 강우강도와 강우지속시간을 산정하였다. 또한 수위-유량관계 곡선식을 이용하여 기준 홍수위에 따라 홍수량 범위를 결정하고, SWMM모형을 이용하여 강우조건에 따른 지점별 홍수량을 산정하여 예보지점별로 기준홍수 위에 따른 홍수량을 산정하였다. 산정된 강우 시나리오에 따른 강우정보와 기준 홍수위에 따른 홍수량을 이용하여 flow nomograph를 개발하였으며, 이를 실제 홍수사상에 적용하여 평가하였다. 평가 결과 청계천 유역에 대해 flow nomograph의 적용성이 높은 것으로 나타났다. 향후 청계천과 같은 도시하천유역의 홍수예측 방법으로 활용도가 높을 것으로 판단된다.

Effects of Combustor-Level High Inlet Turbulence on the Endwall Flow and Heat/Mass Transfer of a High-Turning Turbine Rotor Cascade

  • Lee, Sang-Woo;Jun, Sang-Bae;Park, Byung-Kyu;Lee, Joon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제18권8호
    • /
    • pp.1435-1450
    • /
    • 2004
  • Experimental data are presented which describe the effects of a combustor-level high free-stream turbulence on the near-wall flow structure and heat/mass transfer on the endwall of a linear high-turning turbine rotor cascade. The end wall flow structure is visualized by employing the partial- and total-coverage oil-film technique, and heat/mass transfer rate is measured by the naphthalene sublimation method. A turbulence generator is designed to provide a highly-turbulent flow which has free-stream turbulence intensity and integral length scale of 14.7% and 80mm, respectively, at the cascade entrance. The surface flow visualizations show that the high free-stream turbulence has little effect on the attachment line, but alters the separation line noticeably. Under high free-stream turbulence, the incoming near-wall flow upstream of the adjacent separation lines collides more obliquely with the suction surface. A weaker lift-up force arising from this more oblique collision results in the narrower suction-side corner vortex area in the high turbulence case. The high free-stream turbulence enhances the heat/mass transfer in the central area of the turbine passage, but only a slight augmentation is found in the end wall regions adjacent to the leading and trailing edges. Therefore, the high free-stream turbulence makes the end wall heat load more uniform. It is also observed that the heat/mass transfers along the locus of the pressure-side leg of the leading-edge horseshoe vortex and along the suction-side corner are influenced most strongly by the high free-stream turbulence. In this study, the end wall surface is classified into seven different regions based on the local heat/mass transfer distribution, and the effects of the high free-stream turbulence on the local heat/mass transfer in each region are discussed in detail.