• Title/Summary/Keyword: Flow Value

Search Result 3,536, Processing Time 0.046 seconds

Peak Expiratory Flow in Normal Healthy Korean Subjects Measured by Mini-Wright Peak Flow Meter (Mini-Wright Peak Flow Meter로 측정한 한국 성인의 최고호기유량의 정상치)

  • Kim, Young-Sam;Ahn, Ae-Ran;Kim, Se-Kyu;Chang, Joon;Ahn, Chul-Min;Oh, Jai-Joon;Kim, Sung-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.320-333
    • /
    • 2001
  • Background : Peak expiratory flow (PEF) provides a simple, quantitative, and reproducible measure of the existence and severity of airflow obstructions. Peak flow meters are designed to monitor the condition asthma patients. There are many reports showing the normal predicted value of PEF in other countries. Studies on healthy Korean adults have been performed in a relatively small sample number and a lower limit for the normal value was not reported. Therefore, an attempt to provide normal predictive PEF value with a lower limit was made. Method : The PEF(Mini-Wright Peak Flow Meter) measurements and spirometry were done in 233 men and 631 women without history of respiratory disease. All subjects were non-smokers with no respiratory symptoms. The normal predictive value and its lower limit were developed by multiple regression analysis. The result was compared with regression equations in other reports. Results : The regression equation for the normal PEF predictive value(L/min) is $25.117+4.587{\times}$Age(year)-$0.064{\times}Age^2+2.931{\times}$Height(cm) in men($R^2=025$), and 146.942-$0.011{\times}Age^2+1.795{\times}$Height(cm)+$0.836{\times}$Weight(kg) in women($R^2=0.21$). The regression equation for the lower limit of this value (L/min) is $25.117+4.587{\times}$Age(year)-$0.064{\times}Age^2+1.936{\times}$Height(cm) in men, and $146.942-0.011{\times}Age^2+1.232{\times}$Height(cm)+$0.481{\times}$Weight(kg) in women. The residuals were normally distributed. The PEF in Korean males was sililar to those reported in British and Japanese subjects. The PEF in Korean females was similar to that in British subjects, but higher than the PEF in Japanese subjects. The lower limit of normal value was 71% of normal predictive PEF value in men and 76% in women. Conclusion : The normal predictive PEF value and its lower limit was measured from 233 male and 631 female asymptomatic, lifelong non-smoking participants. The normal predictive value was different from those of other studies on Korean subjects. Therefore, further studies are required.

  • PDF

Optimal response of conical tool semi angle in ductile metal sheets indentation and its governing mechanics

  • Nazeer, Malik M.;Khan, M. Afzal;Haq, A-Ul
    • Structural Engineering and Mechanics
    • /
    • v.16 no.1
    • /
    • pp.47-62
    • /
    • 2003
  • The nonlinear dependence aspect of various conical tool indentation parameters leading to an optimum tool semi angle value for easiest perforation is plotted and discussed explicitly in this work with the conclusion that tool angle has an optimum response towards most of the indentation parameters. Around this optimum angle, the aluminium sheets showed minimum fracture toughness as well as minimum work input to overcome the offered resistance. At the end, the mechanism leading to this phenomenon is presented with the conclusion that plastic flow dominates as the dimple semi cone angle reaches 35 and both pre and post plastic flow perforations lead the tool semi cone angle value towards this dimple cone semi angle of plastic flow initiation for its optimum performance. It is also concluded that specimen material failure is solely under tensile hoop stress and hence results into radial cracks initiation and propagation.

Numerical Analysis on Effects of Free-Stream Turbulence Intensity on the Three-dimensional Turbulent Flow Characteristics in a Turbine Cascade (자유유동 난류강도가 터빈 캐스케이드내 3차원 난류유동 특성에 미치는 영향에 관한 전산해석)

  • Yoon, Deok-Kyu;Lee, Wu-Sang;Kim, Dae-Hyun;Chung, Jin-Taek
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.371-374
    • /
    • 2006
  • The objective of this study is to determine the influence of free-stream turbulent intensity on the three-dimensional turbulent flow in a linear turbine cascade. The range of free-stream turbulence intensity considered is 0.7~10%. This study was performed numerically. The results show that the mass averaged loss coefficient increased according to the increase of free-stream turbulence intensity due to increased value of the mass averaged total pressure loss coefficient which was higher than the decreased value of the mass averaged secondary flow loss coefficient. The loss coefficient distribution was changed suddenly at a free-stream turbulence intensity of 10% while the loss coefficient distribution was rarely changed at a lower free-stream turbulence intensity of 5%.

  • PDF

Improved Turbulence Model on the 3 Dimensional Plane of Symmetry Flow (3차원 대칭단면 유동장에서의 개선된 난류모델)

  • Sohn C. H.
    • Journal of computational fluids engineering
    • /
    • v.2 no.2
    • /
    • pp.1-8
    • /
    • 1997
  • Two versions of anisotropic k-ε turbulence model are incorporated in the modified k-ε model of Sohn et al. to avoid the need for the experimental normal stress value in the model and applied to convergent and divergent flows with strong and adverse pressure gradients in the plane of symmetry of a body of revolution. The models are the nonlinear k-ε model of Speziale and the anisotropic model of Nisizima & Yoshizawa. All of the models yield satisfactory results for relatively complex flow on a plane-of-symmetry boundary layer. The results of the models are compared with those results of experimental normal stress value.

  • PDF

Performance Test for a Centrifugal Air Compressor (원심형 공기압축기 성능시험)

  • 신유환;안이기;김광호;손병진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1964-1971
    • /
    • 1995
  • In the present study, the performance characteristics of a centrifugal air compressor were investigated experimentally. The PC controlled performance test facility for a centrifugal air compressor driven by an electric motor with a gear box to achieve higher compressor rotating speed was set up in the present study. The performance test for a turbocharger compressor of a diesel engine was conducted, and in a case of 34,800 rpm, pressure ratio 1.18, flow rate 0.09kg/s, compressor efficiency 61% were investigated. Adiabatic power for a tested compressor showed maximum value at mass flow ratio 0.8. The value of mass flow ratio of maximum efficiency was about 0.37, it was independent of compressor rotating speed.

TRIPLE SOLUTIONS IN NATURAL CONVECTION OF A FLUID IN A HORIZONTAL ANNULUS WITH CONSTANT TEMPERATURE WALLS (일정 온도 벽면을 갖는 수평 환형공간 내의 유체의 자연 대류에서의 삼중해)

  • Yoo, Joo-Sik
    • Journal of computational fluids engineering
    • /
    • v.22 no.1
    • /
    • pp.110-115
    • /
    • 2017
  • Natural convection of a fluid with the Prandtl number of 7(water) in a horizontal annulus with constant temperature walls is numerically investigated. The inner cylinder is hotter than the outer cylinder. The flows are classified by the number of eddies in a half annulus. It is found that dual or triple solutions exists above a critical Rayleigh number for an annulus with a aspect ratio $D_i/L=4$. Transitions of $3{\rightarrow}1$ and $2{\rightarrow}1$ eddy flow occur with decrease of Rayleigh number. However, reverse transitions of $1{\rightarrow}3$ and $1{\rightarrow}2$ eddy flow do not occur with increase of Rayleigh number, and no hysteresis phenomenon is observed. In the regime of triple solutions, the 3 eddy flow has the largest mean Nusselt number value and the 1 eddy flow has the smallest value.

Inter-comparison of Bell Prover using Sonic Nozzles (소닉노즐을 이용한 벨 푸루버의 국제비교)

  • Choi, Hae Man;Park, Kyung-Am
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.1 s.22
    • /
    • pp.24-29
    • /
    • 2004
  • The inter-comparison of standards is required to be recognized the calibration results. The sonic nozzle package is developed to do inter-comparison of the bell preyer used to calibrate many gas flow meters for industries. Four national metrology institutes (KRISS, CMS, CENAM, NEL) were participated in this inter-comparison. The deviation of calibration data from the average value was small at the low flow rate and large at the high flow rate, respectively At the high flow rate, the deviation was larger than the expected value from uncertainties asserted by NMIs. This means there are some problems in the uncertainty evaluation and experiment procedures in some of the participated NMIs.

A Study on the Lateral Flow of the Silts which is Polluted with a Garbage Leachate to the Dyes (쓰레기 침출수와 염료로 오염된 실트지반의 측방유동에 관한 연구)

  • Ahn, Jong-Pil;Park, Sang-Bum;Ahn, Ki-Mun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1157-1166
    • /
    • 2008
  • Critical surcharge value of silt ground polluted with garbage leachate to the dyes $q_{cr}=3.73c_u$ and ultimate bearing capacity value $q_{ult}=8.60c_u$. Lateral flow pressure at polluted silt ground was about $P_{max}$/3 and depth of maximum lateral flow pressure was found at that of H/3 of soft layer thickness(H). Expression of polluted silt ground of fracture baseline at stability control charge by Matsuo Kawamura is $S_v=3.56\exp\{0.51(Y_m/S_v)\}$.

  • PDF

Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2015
  • We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

Estimation of Magnitude of Debris Flow and Correlation Analysis Between Influencing Factors (토석류 규모 산정과 영향인자와의 상관성 분석)

  • Choi, Young-Nam;Hwan, Hui-Seok;Lee, Hyung-Ho;Yoo, Nam-Jae
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.79-87
    • /
    • 2017
  • In this paper, for 43 sites neighboring to western area of Gangwondo where disaster of debris flow occurred from 2006 to 2013, magnitude of debris flow was estimated from results of site investigation and correlation analysis between influencing factors to its magnitude was performed. Magnitude of channelized debris flow was found greater by 6.5 times of that of hill slope debris flow and approximately 5% of total volume was occurred at initiation part of channelized debris flow. As results of analyzing yield rate of debris flow, for channelized debris flow, yield rate values of $19m^3/m$ and $8m^3/m$ were obtained for total volume being over $10,000m^3/m$ as the large scale of debris flow and less than $10,000m^3/m$ respectively, and value of $5m^3/m$ was estimated for hill slope debris flow. As results of correlation analysis of influencing factors to magnitude of debris flow, runoff distance and erosion width were very highly correlated to its magnitude whereas average slope of basin and erosion depth showed relatively low correlation. In particular, value of erosion depth was in the range of 0.5-2.6 m, being similar range to the value proposed by Ikeya (1981). Triggering rainfall to debris flow such as continuous rainfall and maximum intensity of hour rainfall were analyzed to have low correlation with magnitude of debris flow.