DOI QR코드

DOI QR Code

Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho (Department of Oriental Biomedical Engineering, Sangji University) ;
  • Lee, Sang-Suk (Department of Oriental Biomedical Engineering, Sangji University)
  • Received : 2015.02.10
  • Accepted : 2015.03.17
  • Published : 2015.03.31

Abstract

We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

Keywords

References

  1. S. S. Lee, D. H. Nam, Y. S. Hong, W. B. Lee, I. H. Son, K. H. Kim, and J. G. Choi, Sensors 11, 1784 (2011). https://doi.org/10.3390/s110201784
  2. D. H. Nam, W. B. Lee, Y. S. Hong, and S. S. Lee, Sensors 13, 4714 (2013). https://doi.org/10.3390/s130404714
  3. R. Asmar, A. Benetos, G. M. London, C. Hughe, Y. Weiss, J. Topouchian, B. Laloux, and M. Safar, Blood Pressure 4, 48 (1995). https://doi.org/10.3109/08037059509077567
  4. Q. Yu, J. Zhou, and Y. C. Fung, Am. J. Physiol. Heart Circ. Physiol. 265, 52 (1993).
  5. M. F. P. O'Rourke, R. P. Kelly, and A. P. Avolio, The Arterial Pulse, 1st Ed.; Lea & Febiger, Philadelphia, PA, USA (1992).
  6. A. Yamashina, H. Tomiyama, T. Arai, Y. Koji, M. Yambe, H. Motobe, Z. Glunizia, Y. Yamamoto, and S. Hori, Hypertens. Res. 26, 801 (2003). https://doi.org/10.1291/hypres.26.801
  7. J. C. Bramwell and A. V. Hill, Proceedings of the Royal Society, London (1922) p. 298.
  8. John Allen, Photoplethysmography and its Application in Clinical Physiological Measurement 28, R1 (2007).
  9. K. Shelley and S. Shelley, Pulse Oximeter Waveform: Olethysmography, in Clinical Monitorning, Carol Lake, R. Hines, and C. Blitt, Eds.: W. B. Saunders Company (2001) p. 420.
  10. A. Fronek, Noninvasive diagnosis in vascular disease, McGraw Hill, New York (1989).
  11. I. H. Son and S. S. Lee, J. Korean Magn. Soc. 21, 104 (2011). https://doi.org/10.4283/JKMS.2011.21.3.104
  12. M. C. Ahn, J. G. Choi, I. H. Son, S. S. Lee, and K. H. Kim, J. Korean Magn. Soc. 20, 106 (2010). https://doi.org/10.4283/JKMS.2010.20.3.106
  13. S. S. Lee, M. C. Ahn, and S. H. Ahn, J. Magn. 14, 132 (2009). https://doi.org/10.4283/JMAG.2009.14.3.132
  14. S. S. Lee, I. H. Son, J. G. Choi, D. H. Nam, Y. S. Hong, and W. B. Lee, J. Korean Phys. Soc. 58, 349 (2011). https://doi.org/10.3938/jkps.58.349