• Title/Summary/Keyword: Flow Rate Change

Search Result 1,332, Processing Time 0.029 seconds

Electrical and Optical Characteristics of IZO Thin Films Deposited in Different Oxygen Flow Rate (산소 유량에 따른 IZO 박막의 전기적 및 광학적 특성)

  • Kwon, Su-Kyeong;Lee, Kyu-Mann
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.49-54
    • /
    • 2013
  • In this study, we have investigated the effect of the substrate temperature and oxygen flow rate on the characteristics of IZO thin films for the OLED (organic light emitting diodes) devices. For this purpose, IZO thin films were deposited by RF magnetron sputtering at room temperature and $300^{\circ}C$ with various $O_2$ flow rate. In order to investigate the influences of the oxygen, the flow rate of oxygen in argon mixing gas has been changed from 0.1sccm to 0.5sccm. IZO thin films deposited at room temperature show amorphous structure, whereas IZO thin films deposited at $300^{\circ}C$ show crystalline structure having an (222) preferential orientation regardless of $O_2$ flow rate. The electrical resistivity of IZO film increased with increasing flow rate of $O_2$ under Ar+$O_2$. The change of electrical resistivity with increasing flow rate of $O_2$ was mainly interpreted in terms of the charge carrier concentration rather than the charge carrier mobility. The electrical resistivity of the amorphous-IZO films deposited at R.T. was lower than that of the crystalline-IZO thin films deposited at $300^{\circ}C$. The change of electrical resistivity with increasing substrate temperature was mainly interpreted in terms of the charge carrier mobility rather than the charge carrier concentration. All the films showed the average transmittance over 85% in the visible range. The current density and the luminance of OLED devices with IZO thin films deposited at room temperature in 0.1sccm $O_2$ ambient gas are the highest amongst all other films. The optical band gap energy of IZO thin films plays a major role in OLED device performance, especially the current density and luminance.

Structural and Electrical Characteristics of IZO Thin Films deposited at Different Substrate Temperature and Oxygen Flow Rate (증착 온도 및 산소 유량에 따른 IZO 박막의 구조적 및 전기적 특성)

  • Han, Seong-Ho;Lee, Kyu Mann
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.4
    • /
    • pp.25-30
    • /
    • 2012
  • In this study, we have investigated the effect of the substrate temperature and oxygen flow rate on the characteristics of IZO thin films for the organic light emitting diodes (OLED) devices. For this purpose, IZO thin films were deposited by RF magnetron sputtering at room temperature and $300^{\circ}C$ with various $O_2$ flow rate. In order to investigate the influences of the oxygen, the flow rate of oxygen in argon mixing gas has been changed from 0.1sccm to 0.5sccm. IZO thin films deposited at room temperature show amorphous structure, whereas IZO thin films deposited at $300^{\circ}C$ show crystalline structure having an (222) preferential orientation regardless of $O_2$ flow rate. The electrical resistivity of IZO film increased with increasing flow rate of $O_2$ under $Ar+O_2$. The change of electrical resistivity with increasing flow rate of $O_2$ was mainly interpreted in terms of the charge carrier concentration rather than the charge carrier mobility. The electrical resistivity of the amorphous-IZO films deposited at R.T. was lower than that of the crystalline-IZO thin films deposited at $300^{\circ}C$. The change of electrical resistivity with increasing substrate temperature was mainly interpreted in terms of the charge carrier mobility rather than the charge carrier concentration. All the films showed the average transmittance over 83% in the visible range.

A Study on the Phenomena of Dust Removal by the Layout Changes in the Turbulent Type Clean Room (난류형 클린룸내의 Layout 변화에 따른 분진제거 특성에 관한 연구)

  • Kim, Yeon-Hui
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.41
    • /
    • pp.80-87
    • /
    • 2007
  • The purpose of this paper is to investigate the removal efficiency of fine dusts as the configuration condition of machinery and equipments in Clean Room and to analyze the flowing behaviors of fine dusts as the layout of Clean Room. The layout of the Clean Room was classified into side layout type, 2 center line type and center concentration type layout, and the flow rates used in this research were 0.22m/s, 0.44m/s and0.80m/s. Dust removal efficiency as layout change was decreased 37% for side layout type, 31% for 2 centerline type and 20% for center concentration type layout at the flow rate of 0.22m/s, compared with the state without machinery and equipments in Clean Room. The efficiency was decreased 42% for side layout type,22% for 2 center line type and 8% for center concentration type layout at the flow rate of 0.44m/s, and decreased 20% for side layout type, 18% for 2 center line type and 10% for center concentration type layout at the flow rate of 0.80m/s. According to the result of dust removal behavior, $0.3\mum$, $1\mum$and $3\mum$dust except for $5\mum$showed the higher change of the behavior in side layout type than in center concentration type layout due to the change of air flow. It was confirmed that removal behavior depends on the layout of machinery and equipments as the dust size decreases.

  • PDF

The effect of nitrogen flow rate in a predeposition with Boron nitride (보론 나이트라이드를 사용하는 Predeposition 공정에서 질소류량의 영향)

  • 박형무;김충기
    • 전기의세계
    • /
    • v.30 no.4
    • /
    • pp.227-230
    • /
    • 1981
  • The variation of sheet resistance and the reduction of masking oxide thickness with the flow rate of nitrogen gas has been measured in Boron predeposition process with Planar Diffusion source, BN-975. At 900.deg. C, the sheet resistance varied as much as 75% when the nitrogen flow rate was changed from 0.4 liters/min to 2.0 liters/min. At 975.deg. C, however, only 12% of sheet resistance variation was observed under the same flow rate change. The reduction of masking oxide thickness at 975.deg. C for a 5 min predeposition was 600 nm when the nitrogen flow rate was 0.4 liters/min. When the flow rate incresased to 1.9 liters/min, however, only 100nm of masking oxide was consumed in a similar predeposition process.

  • PDF

A Study on the Geothermal Heat Pump System Performance Analysis according to Water Flow Rate Control of the Geothermal Water Circulation Pump (지열순환펌프 유량변화에 따른 지열히트펌프시스템의 에너지 성능 평가)

  • Jung, Young-Ju;Jo, Jae-Hun;Kim, Yong-Shik;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.103-109
    • /
    • 2014
  • It is important to control the amount of supply water flow rate at all kinds of HVAC systems in order to maintain IAQ and energy efficiency. The most of buildings installed geothermal heat pumps is using fixed water flow rate in spite of the excellent performance of geothermal heat pumps. Especially when the air-conditioning load is low, the flow rate control may be possible to save energy to operate. However, it is effective to apply the variable flow control system in order to reduce energy consumption. Therefore, the purpose of this study, change a water flow rate and improve the whole performance of the geothermal heat pump. Geothermal heat pump system is modeled after the selection of the applied building, by setting the flow rate control to be analyzed through a simulation of performance evaluation. Building energy saving according to the flow rate of the ground circulating water analyze quantitatively and to investigate the importance of the flow control.

A Method for the Measurement of Flow Rate in Pipe using a Microphone Array (등간격으로 배열된 마이크로폰을 이용한 관내 유량측정 방법)

  • Kim, Yong-Beum;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1667-1674
    • /
    • 2000
  • A new method is proposed to measure the flow rate in a pipe by multiple measurements of acoustic pressure using a microphone array. It is based on the realization that variation in flow velocity affects the change in wave number. The method minimizes measurement random errors and sensor mismatch errors thereby providing practically realizable flow rate measurement. One of the advantages of the method is that it does not obstruct the flow field and can provide the time-spatial mean flow rate. Numerical simulations and experiments were conducted to verify the utility of this method.

  • PDF

The Effect of Surrounding Gas Flow on the Heat Transfer of the Falling Film Flowing Down the Outside of a Vertical Tube (수직원관 외부 유하액막 열전달에 주변 기체유동이 미치는 영향)

  • 권경민;정시영;김병주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.996-1003
    • /
    • 2002
  • Heat transfer characteristics were investigated for the falling film flowing down the outside of an electrically heated vertical tube. Water was used for the falling film, and its Reynolds number was varied in the range of 70~500. Because water is heated and evaporated as it flows down, both sensible and latent heat transfer should be considered. The effect of the surrounding air movement was investigated by changing the direction of the air injection; without air injection, parallel-flow, and counter-flow. For all cases, sensible teat transfer rate was almost linearly increased with the increasing film flow rate. It was found that the film heat transfer coefficient was hardly influenced by the parallel air flow. However, the counter-flow of air reduced the heat transfer coefficient, which might be caused by the uneven distribution or flooding of the film. At high heat flux, a sudden change of the film heat transfer coefficient was detected as the film flow rate reached the transition value. It is supposed that this phenomenon was caused by the change in the film flow pattern.

A Fundamental Study on Offshore Structures of high pressure control valve (해양구조물용 고압 컨트롤 밸브에 대한 기초 연구)

  • Lee, Chi-Woo;Jang, Sung-Cheol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.883-888
    • /
    • 2010
  • This study have goal with conceptual design for Offshore Structures of high pressure control valve for localization. Ball valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the Offshore Structures high pressure control valve. Numerical simulation using CFD (Computational Fluid Dynamic) in order to predict a mass flow rate and a flow coefficient form flow dynamic point of view. The working fluid assumed the glycerin (C3H8O3). The valve inlet and outlet setup a pressure boundary condition. The outlet pressure was fixed by atmospheric pressure and calculated until increasing 1bar to 10bar. CFD analysis used STAR-CCM+ which is commercial code and Governing equations were calculated by moving mesh which is rotated 90 degrees when ball valve operated opening and closing in 1 degree interval. The result shows change of mass flow rate according to opening and closing angle of valve, Flow decrease observed open valve that equal percentage flow paten which is general inclination of ball valve. Relation with flow and flow coefficient can not be proportional according to inlet pressure when compare with mass flow rate. Because flow coefficient have influence in flow and pressure difference. Namely, flow can be change even if it has same Cv value. The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and seat structure.

Effect of the yield criterion on the strain rate and plastic work rate intensity factors in axisymmetric flow

  • Lyamina, Elena A.;Nguyen, Thanh
    • Structural Engineering and Mechanics
    • /
    • v.58 no.4
    • /
    • pp.719-729
    • /
    • 2016
  • The main objective of the present paper is to study the effect of the yield criterion on the magnitude of the strain rate and plastic work rate intensity factors in axisymmetric flow of isotropic incompressible rigid perfectly plastic material by means of a problem permitting a closed-form solution. The boundary value problem consisting of the axisymmetric deformation of a plastic tube is solved. The outer surface of the tube contracts. The radius of the inner surface does not change. The material of the tube obeys quite a general yield criterion and its associated flow rule. The maximum friction law is assumed at the inner surface of the tube. Therefore, the velocity field is singular near this surface. In particular, the strain rate and plastic work rate intensity factors are derived from the solution. It is shown that the strain rate intensity factor does not depend on the yield criterion but the plastic work rate intensity factor does.

An Analysis of the Effect of Climate Change on Flow in Nakdong River Basin Using Watershed-Based Model (유역기반 모형을 이용한 기후변화에 따른 낙동강 유역의 하천유량 영향 분석)

  • Shon, Tae-Seok;Lee, Sang-Do;Kim, Sang-Dan;Shin, Hyun-Suk
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.10
    • /
    • pp.865-881
    • /
    • 2010
  • To evaluate influence of the future climate change on water environment, it is necessary to use a rainfall-runoff model, or a basin model allowing us to simultaneously simulate water quality factors such as sediment and nutrient material. Thus, SWAT is selected as a watershed-based model and Nakdong river basin is chosen as a target basin for this study. To apply climate change scenarios as input data to SWAT, Australian model (CSIRO: Mk3.0, CSMK) and Canadian models (CCCma: CGCM3-T47, CT47) of GCMs are used. Each GCMs which have A2, B1, and A1B scenarios effectively represent the climate characteristics of the Korean peninsula. For detecting climate change in Nakdong river basin, precipitation and temperature, increasing rate of these were analyzed in each scenarios. By simulation results, flow and increasing rate of these were analyzed at particular points which are important in the object basin. Flow and variation of flow in the scenarios for present and future climate changes were compared and analyzed by years, seasons, divided into mid terms. In most of the points temperature and flow rate are increased, because climate change is expected to have a significant effect on rising water temperature and flow rate of river and lake, further on the basis of this study result should set enhancing up water control project of hydraulic structures caused by increasing outer discharge of the Nakdong River Basin due to climate change.