• 제목/요약/키워드: Flow Quantity Efficiency

검색결과 89건 처리시간 0.024초

이젝터의 노즐 형상이 흡입유량에 미치는 영향 (Effect of Nozzle Geometry on the Suction Flow Rate in a Ejector)

  • 김유준;박정우;서이수
    • 한국유체기계학회 논문집
    • /
    • 제12권6호
    • /
    • pp.13-17
    • /
    • 2009
  • Ejector is an equipment devised for making use of the low pressure occurring from the fast fluid injection and it is a transportation equipment which can obtain vacuum using the kinetic energy of the fluid. This ejector system is, nowadays, widely used for construction machinery, heavy equipments, the cooling and ventilation of electronic devices and for the various fluid transportation and pumps. In this study, it is attempted to perform a numerical analysis and an experiment to find out the characteristics of fluid quantity, velocity and the pressure distribution of the induction pipe by changing the length and the radius ratio of the nozzle of ejector. From the results, it is investigated that the distributions of velocity and pressure of induction pipe attached are changing with the length and the radius ratio of the nozzle. In addition, it is shown that for the small and large ejector, the efficiency is the maximum when the length of the nozzle arrived to the neck of the ejector, however, if it is installed at below or above the neck the efficiency is rather decreased.

외기 전용 공조기의 동특성 시뮬레이션 (Dynamic Simulation of a Dedicated Outdoor Air-conditioning System)

  • 김정민;김영일;정광섭;박승태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

Performance and Flow Condition of Contra-rotating Small-sized Axial Fan at Partial Flow Rate

  • Shigemitsu, Toru;Fukutomi, Junichiro;Okabe, Yuki;Iuchi, Kazuhiro
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.271-278
    • /
    • 2010
  • Small-sized axial fans are used as air cooler for electric equipments. But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices. Therefore, higher rotational speed design is conducted, although, it causes the deterioration of efficiency and the increase of noise. Then the adoption of contrarotating rotors for the small-sized axial fan is proposed for the improvement of performance. In the present paper, the performance curves of the contra-rotating small-sized axial fan with 100mm diameter are shown and the velocity distributions at a partial flow rate at the inlet and the outlet of each front and rear rotor are clarified with experimental results. Furthermore, the flow conditions between front and rear rotors of the contra-rotating small-sized axial fan are investigated by numerical analysis results and causes of the performance deterioration of the contra-rotating small-sized axial fan at the partial flow rate is discussed.

친환경 도로노선의 재해위험도 평가시스템 개발 (Development of Disaster Risk Analysis System for Environment Friendly Road)

  • 송민태;강호근;김흥래;이태옥;이한주
    • 한국도로학회논문집
    • /
    • 제14권5호
    • /
    • pp.123-132
    • /
    • 2012
  • PURPOSES: This study is to investigate the consideration which relates with a disaster from route alignment process and proposed the method it will be able to evaluate a disaster danger fixed quantity. METHODS: Use the landslide disaster probabilistic map of GIS based and in about landslide occurrence of the route alignment at the time of neighboring area after evaluating a risk fixed quantity, it compared LCC expense in about each alternative route. It developed the system it will be able to analyze a LCC and a disaster risk in about the alternative route. In order to verify a risk analytical algorithm and the system which are developed it selected national road 59 lines on the demonstrative route and it analyzed a disaster risk. RESULTS: Demonstrative route not only the disaster risk to be it will be able to compare a disaster risk fixed quantity like the economical efficiency degree in compliance with LCC expense productions it compared and there being the designer will be able to decide the alternative route, it confirmed. CONCLUSIONS: Roads can be designed by considering occurs repeatedly landslides and debris flow caused by disasters in advance and expect to be able to effect that can reduce the overall cost to recover losses caused by the disaster, and temporally loss is expected.

가스 크로마토그래픽 컬럼의 유동특성에 대한 수치적 연구 (A NUMERICAL STUDY ON THE FLOW CHARACTERISTICS OF GAS CHROMATOGRAPHIC COLUMN)

  • 김태안;김윤제
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.21-26
    • /
    • 2005
  • Gas Chromatography (GC) is a wisely technique used for the separation and analysis of liquid and gas sample. Separation of the sample vapors is achieved via their differential migration through a capillary column with an insert carrier gas. The identity and quantity of each vapor in the mixer can be determined from its retention time in the column and a particular property of the gas, such as thermal conductivity, which can be related to the concentration of sample vapor in the carrier gas. Therefore, the flow characteristics in the spiral gas chromatographic column are numerically investigated in this study. Especially, different pressure drop between the front and the rear of GC column with various flow rates is estimated the governing equations are derived from making using of three-dimensional Naver-Stokes equation with incompressible and laminar model due to the nature of low Reynolds number flow. Using a commercial code, FLUENT, the pressure and flow fields in GC column are calculated with various flow rates. The characteristics of thermal cycling which is one of the most important factors affecting the column efficiency and analysis time is also estimated. Furthermore, numerical analyses are also carried out by using commercial code, ANSYS, with various values of power, which is applied to the heating element located at lower GC column.

  • PDF

소규모 밭 관개용수 확보를 위한 소류천 빗물 집수장치의 현장 평가 (On-site Evaluation of Rainwater Harvesting Device for Securing Irrigation Water in Small Fields)

  • 최용훈;김영진;김민영;전종길
    • 한국농공학회논문집
    • /
    • 제60권1호
    • /
    • pp.31-36
    • /
    • 2018
  • A rainwater harvesting device was developed for runoff flow harvesting in a small stream or channel and its performance was evaluated in small fields. The rainwater harvesting device has slits on its side of cylindrical volume in 15 cm diameter and 70 cm length, which is designed to increase its water flow harvesting capacity. The maximum collectable water quantity was about 0.0022 ton/sec (130 L/min). Rainwater harvesting device were installed in two locations (P1, P2). P1 is a point for rainfall runoff flow harvesting. P2 is a point for ordinary flow harvesting. During this study, total rainfall depth was 334.5 mm. Runoff of 1,722 ton and 7,984 ton occurred in P1 and P2, and 273 ton and 125 ton were collected by this rainwater harvesting device. Harvesting efficiency was calculated as 15.85 % and 1.57 % in P1 and P2. Clogging of screen filter media in the cylinder due to soil and suspended solids has lowered the harvesting efficiency. However, it was possible to harvest 30 ton/month of rainwater harvesting and it is expected that it will help to solve short-term water shortage.

Multi-objective optimization of stormwater pipe networks and on-line stormwater treatment devices in an ultra-urban setting

  • Kim, Jin Hwi;Lee, Dong Hoon;Kang, Joo-Hyon
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.75-82
    • /
    • 2019
  • In a highly urbanized area, land availability is limited for the installation of space consuming stormwater systems for best management practices (BMPs), leading to the consideration of underground stormwater treatment devices connected to the stormwater pipe system. The configuration of a stormwater pipe network determines the hydrological and pollutant transport characteristics of the stormwater discharged through the pipe network, and thus should be an important design consideration for effective management of stormwater quantity and quality. This article presents a multi-objective optimization approach for designing a stormwater pipe network with on-line stormwater treatment devices to achieve an optimal trade-off between the total installation cost and the annual removal efficiency of total suspended solids (TSS). The Non-dominated Sorted Genetic Algorithm-II (NSGA-II) was adapted to solve the multi-objective optimization problem. The study site used to demonstrate the developed approach was a commercial area that has an existing pipe network with eight outfalls into an adjacent stream in Yongin City, South Korea. The stormwater management model (SWMM) was calibrated based on the data obtained from a subcatchment within the study area and was further used to simulate the flow rates and TSS discharge rates through a given pipe network for the entire study area. In the simulation, an underground stormwater treatment device was assumed to be installed at each outfall and sized proportional to the average flow rate at the outfall. The total installation cost for the pipes and underground devices was estimated based on empirical formulas using the flow rates and TSS discharge rates simulated by the SWMM. In the demonstration example, the installation cost could be reduced by up to 9% while the annual TSS removal efficiency could be increased by 4% compared to the original pipe network configuration. The annual TSS removal efficiency was relatively insensitive to the total installation cost in the Pareto-optimal solutions of the pipe network design. The results suggested that the installation cost of the pipes and stormwater treatment devices can be substantially reduced without significantly compromising the pollutant removal efficiency when the pipe network is optimally designed.

그래픽 인터페이스를 통한 조류계산 설계 (The Architecture of Load Flow under Graphic Interface)

  • 황인준;김건중;김규왕;신만철;오성균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.126-128
    • /
    • 2004
  • In these days, our social infra which are computer and internet has been developed and our community has been digitalized with a large quantity information that can be sharable or productive. So we can say that older knowledge organization based on the man power is changing with automatical and intellectual aspect. Thus we have to apply this movement to get the high efficiency and the competitive power in the organization and to take the voluntaries attitude of operator with real time inputting or fast calculating speed. Beside most of developed countries are owned their power system analysis software. Like kind of this facts can affect for national reliance. So in this paper we propose that the suggestion for both field power system and IT how these can be cooperated. The note that this paper is came from the project which name is Graphics Power Flow analysis.

  • PDF

준설매립지반 표층건조처리를 위한 트렌치 굴착시 간극수의 침투해석 (Analysis of seepage in trenching for surface desiccation of dredged soft ground)

  • 정하익;오인규;이용길;이승원;이영남
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.529-536
    • /
    • 2002
  • The purpose of this paper os to present and discuss some of flow and drain observed in modelling results. Because dredged fill ground of Yul-Chon located in the south coast of Korea is very soft, this ground should be improved after operation of surface stabilization. There are surface stabilization method such as chemical stabilization, desiccation, horizontally vacuum drain, replacement, and geosynthetics. In Yul-Chon, PTM(Progressive Trenching Method) is adopted to provide the necessity condition of surface desiccation. In the case trench in the dredged soft ground is formed by PTM equipment, pore water in the ground is drained through trench. There, drain and desiccation of surface ground increase, and bearing capacity is improved. In this research, when trench in the dredged soft ground is formed by PTM equipment, permeable characteristics and drain efficiency of pore-water are analyzed using SEEP/W software package. Results show variation of total head, pressure head, flux, hydraulic gradient, and flow quantity.

  • PDF

지하철 목업차량내 객실 공기정화장치의 미세먼지(PM10) 및 $CO_2$ 저감성능평가 (Removal Efficiency of PM10 & $CO_2$ in Subway Mock-up Cabin)

  • 권순박;박덕신;조영민;김종범;조관현;남궁석;이주열;김태성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.613-618
    • /
    • 2011
  • More than 7 million persons use Seoul Metropolitan Subways (SMS) everyday and the number has been in increasing trend. With the increasing trend of concerns on indoor air quality(IAQ), the management of IAQ has become an important issue, especially in case of subway operators, because most of subway lines are placed underground with poor ventilation condition. The ultimate object of study develop independent cleaning device that reduce efficient fine particle and $CO_2$. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. Two layered electrically pre-charged filters were used for removing particulate matters and gas absorbers are packed between two layer filters for removing gases pollutants such $CO_2$, VOCs and HCHO. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. SCAP prototype is producted as all in one method which decrease fine dust, $CO_2$ and noxious gas. and basic test carry out with quantity of wind, a gap of pressure, sampling efficiency.

  • PDF