• Title/Summary/Keyword: Flexural Vibration

Search Result 310, Processing Time 0.026 seconds

A Study on the Structural Shape and Vibrational Characteristics of Aluminum Sandwich Panel (알루미늄 샌드위치 패널의 구조적 형상 및 진동 특성에 관한 연구)

  • Bae, Dong-Myung;Son, Jung-Dae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.4
    • /
    • pp.351-359
    • /
    • 2004
  • Aluminum honeycomb sandwich panel (AHSP) not only have high flexural rigidity and strength per density but also excellence in anti-vibration and anti-noise properties. Their properties are very useful for build airplane and high speed crafts, which need lighter-weighted and more strengthed element. Recently, the AHSP is regarded as a promising strength member of light structures like the hull of high speed crafts. Generally, the core shape of aluminum sandwich panel (ASP) is the hexagonal shape of honeycomb. But, in this paper, authors proposed the ASP with pyramid core, as the ASP model of new type, and analysed the structural and vibrational characteristics for aluminum pyramid sandwich panel (APSP) as this new ASP type, according to the thickness variation of core and face, the height variation of core. The applied sandwich models have isotropic and symmetrical aluminum faces and pyramid cores. And, the applied boundary conditions are simple, fixed and free support.

Ultrasonic Cavitation Behavior and its Degradation Mechanism of Epoxy Coatings in 3.5 % NaCl at 15 ℃

  • Jang, I.J.;Jeon, J.M.;Kim, K.T.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.26-36
    • /
    • 2021
  • Pipes operating in the seawater environment faces cavitation degradation and corrosion of the metallic component, as well as a negative synergistic effect. Cavitation degradation shows the mechanism by which materials deteriorate by causing rapid change of pressure or high-frequency vibration in the solution, and introducing the formation and explosion of bubbles. In order to rate the cavitation resistance of materials, constant conditions have been used. However, while a dynamic cavitation condition can be generated in a real system, there has been little reported on the effect of ultrasonic amplitude on the cavitation resistance and mechanism of composites. In this work, 3 kinds of epoxy coatings were used, and the cavitation resistance of the epoxy coatings was evaluated in 3.5% NaCl at 15 ℃ using an indirect ultrasonic cavitation method. Eleven kinds of mechanical properties were obtained, namely compressive strength, flexural strength and modulus, tensile strength and elongation, Shore D hardness, water absorptivity, impact test, wear test for coating only and pull-off strength for epoxy coating/carbon steel or epoxy coating/rubber/carbon steel. The cavitation erosion mechanism of epoxy coatings was discussed on the basis of the mechanical properties and the effect of ultrasonic amplitude on the degradation of coatings.

Performance of self-compacting concrete with manufactured crushed sand

  • Benyamina, Smain;Menadi, Belkacem;Bernard, Siham Kamali;Kenai, Said
    • Advances in concrete construction
    • /
    • v.7 no.2
    • /
    • pp.87-96
    • /
    • 2019
  • Self-compacting concretes (SCC) are highly fluid concrete which can flow without any vibration. Their composition requires a large quantity of fines to limit the risk of bleeding and segregation. The use of crushed sand rich in limestone fines could be an adequate solution for both economic and environmental reasons. This paper investigates the influence of quarry limestone fines from manufactured crushed sand on rheological, mechanical and durability properties of SCC. For this purpose, five mixtures of SCC with different limestone fines content as substitution of crushed sand (0, 5, 10, 15 and 20%) were prepared at constant water-to-cement ratio of 0.40 and $490kg/m^3$ of cement content. Fresh SCC mixtures were tested by slump flow test, V-funnel flow time test, L-box height ratio, segregation resistance and rheological test using a rheometer. Compressive and flexural strengths of SCC mixtures were evaluated at 28 days. Regarding durability properties, total porosity, capillary water absorption and chloride-ion migration were studied at 180 days. For the two test modes in fresh state, the results indicated compatibility between slump flow/yield stress (${\tau}_0$) and V-funnel flow time/plastic viscosity (${\mu}$). Increasing the substitution level of limestone fines in SCC mixtures, contributes to the decrease of the slump flow and the yield stress. All SCC mixtures investigated achieved adequate filling, adequate passing ability and exhibit no segregation. Moreover, the inclusion of limestone fines as crushed sand substitution reduces the capillary water absorption, chloride-ion migration and consequently enhances the durability performance.

Analysis of the Flexural Vibrations for the Rotating Cantilevered Rectangular Plates (회전하는 외팔 사각판의 굽힘진동 해석)

  • 이종민;이영신
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.59-64
    • /
    • 1992
  • 터빈 블레이드와 같이 회전하는 구조물의 파단은 공진 근처에서 진동이 발 생할 때에 이에 기인하는 피로에 의하여 발생한다. 그러므로 이와 같은 파단 을 피하기 위해서는 설계 단계에서 이론적인 계산에 의하여 구조물의 고유 진동수를 결정하는 것이 상당히 중요하다. 판이 회전을 받게 되면 원심력에 의하여 판의 강성이 증가하므로 고유진동수가 회전하지 않는 판의 고유진동 수보다는 상당히 증가하게 된다. 이에 대한 연구가 국내외에서 상당수 행하 여졌지만, 연구의 대부분이 회전의 영향을 고려하지 않은 정지판(stationary plate)에 대한 것이며 뢰전을 고려한 연구는 극히 제한되어 있다. 또한 회전 의 영향을 고려한 연구의 대부분이 해석 대상을 보로서 단순화 시켰고 해법 으로는 유한요소법과 Ritz법 등을 사용하였다. 이는 블레이드가 지니고 있는 기하학적인 형상과 진동 특성이 해석적인 방법으로 해결하는 데에는 상당한 어려움이 있기 때문이다. 실제적으로는 터빈 블레이드와 같은 회전체의 진동 특성이 설치각이나 비틀림각, 판의 형상비, 회전속도 등의 변화에 의하여 영 향을 받기 때문에 보와 같은 진동 거동을 보이기보다는 판이나 셀과 같은 진동 거동을 보이므로 보다 정확한 해석을 수행하기 위해서는 해석 대상을 판이나 셀로서 취급하는 것이 타당하다. 따라서 본 연구에서는 위와 같은 이 유 때문에 해석 대상을 등방성 사각판과 직교이방성 복합재료 사각판으로 선택하였으며, 구조물의 고유진동수에 영향을 미치는 다음과 같은 인자들을 해석에 고려하였다. 1. 회전속도 (rotational speed) 2. 설치각 (setting angle) 3. 허브의 반경 (hub radius) 4. 판의 형상비 (aspect ratio) 5. 적층순서 (stacking sequence)구조물에 대한 동적실험(dynamic test)을 통하여 단기간에 동적특성을 결정하고 SDM(structure dynamic modification)이나 FRS(force response simulation)를 수행하여 임의의 좌표 공간에 대한 진동수준을 해석적으로 예측할 뿐만 아니라 구조물의 진동제어 를 위한 동적인자를 변경시킬 수 있는 정보를 제공하며 장비를 방진할 경우 신뢰성 있는 전달률을 결정할 수 있다. 실험적으로 철교, 교량이나 건물의 철골구조 및 2층 바닥 등 대,중형의 복잡한 구조물에 대항 동특성을 나타내 는 모빌리티를 결정할 경우 충격 가진 실험이 사용되는 실험장비 측면에서 나 실험을 수행하는 과정이 대체적으로 간편하다. 그러나 이 경우 대상 구조 물을 충분히 가진시킬수 있는 용량의 대형 충격기(large impact hammer)가 필요하게 된다. 이러한 동적실험은 약 길이 61m, 폭 16m의 4경간 교량에 대 하여 동적실험을 수행하여 가능성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but stron

  • PDF

A Fundamental Study of VIV Fatigue Analysis Procedure for Dynamic Power Cables Subjected to Severely Sheared Currents (강한 전단 해류 환경에서 동적 전력케이블의 VIV 피로해석 절차에 관한 기초 연구)

  • Chunsik Shim;Min Suk Kim;Chulmin Kim;Yuho Rho;Jeabok Lee;Kwangsu Chea;Kangho Kim;Daseul Jeong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.5
    • /
    • pp.375-387
    • /
    • 2023
  • The subsea power cables are increasingly important for harvesting renewable energies as we develop offshore wind farms located at a long distance from shore. Particularly, the continuous flexural motion of inter-array dynamic power cable of floating offshore wind turbine causes tremendous fatigue damages on the cable. As the subsea power cable consists of the helical structures with various components unlike a mooring line and a steel pipe riser, the fatigue analysis of the cables should be performed using special procedures that consider stick/slip phenomenon. This phenomenon occurs between inner helically wound components when they are tensioned or compressed by environmental loads and the floater motions. In particular, Vortex-induced vibration (VIV) can be generated by currents and have significant impacts on the fatigue life of the cable. In this study, the procedure for VIV fatigue analysis of the dynamic power cable has been established. Additionally, the respective roles of programs employed and required inputs and outputs are explained in detail. Demonstrations of case studies are provided under severely sheared currents to investigate the influences on amplitude variations of dynamic power cables caused by the excitation of high mode numbers. Finally, sensitivity studies have been performed to compare dynamic cable design parameters, specifically, structural damping ratio, higher order harmonics, and lift coefficients tables. In the future, one of the fundamental assumptions to assess the VIV response will be examined in detail, namely a narrow-banded Gaussian process derived from the VIV amplitudes. Although this approach is consistent with current industry standards, the level of consistency and the potential errors between the Gaussian process and the fatigue damage generated from deterministic time-domain results are to be confirmed to verify VIV fatigue analysis procedure for slender marine structures.

Structural Performance and Usability of Void Slab Established in T-deck Plate (T형 데크 플레이트 중공형 슬래브의 구조성능 및 사용성능)

  • Hong, Eun-Ae;Chung, Lan;Paik, In-Kwan;Yun, Sung-Ho;Cho, Seung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.677-684
    • /
    • 2012
  • In recent years, extension of life span of buildings is becoming an important issue in our society. To improve the life span of buildings, rhamen structure construction and long-spanned structures are advantageous. And in order to achieve this goal, structural elements of buildings must be light and slender. As an alternative method, general porous slabs are used frequently domestically and internationally. But the study on the porous slabs using T-deck plate and assembly of light weight precast construction is insufficient at present. In this study, flexural and fatigue tests were performed on six specimens to verify structural performance and serviceability. The main parameters of the specimens were light weight and T-deck plate construction possibility as well as slab thickness. The test results indicated that the strength of porous slabs using T-deck plate and assembly of light weight were much better than general RC slabs and porous slabs without T-deck plate. And stiffness was much better than that of other tested slabs.

Effect of Green Tea Content on Dynamic Modulus of Elasticity of Hybrid Boards Composed of Green Tea and Wood Fibers, and Prediction of Static Bending Strength Performances by Flexural Vibration Test (녹차-목재섬유복합보드의 동적탄성률에 미치는 녹차배합비율의 영향 및 휨 진동법에 의한 정적 휨 강도성능 예측)

  • Park, Han-Min;Lee, Soo-Kyeong;Seok, Ji-Hoon;Choi, Nam-Kyeong;Kwon, Chang-Bea;Heo, Hwang-Sun;Byeon, Hee-Seop;Yang, Jae-Kyung;Kim, Jong-Cheol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.6
    • /
    • pp.538-547
    • /
    • 2011
  • In this study, eco-friendly hybrid composite boards were manufactured from green tea and wood fibers for application as interior materials with various functionalities of green tea and strong strength properties of wood fibers. In this relation, the effect of green tea content on dynamic MOEs (modulus of elasticity) of these green tea and wood fibers composite boards were investigated. The dynamic MOEs of hybrid composite boards were lower than those of control boards without green tea, and the values decreased with the increase of green tea content. Also, the dynamic MOEs appeared to be somewhat different by resin type used for board manufacture. The hybrid composite boards manufactured from $E_1$ grade urea resin, which has higher molar ratio of formaldehyde to urea than that of $E_0$ grade one, were 1.06~1.54 times higher than that manufactured from $E_0$ grade. And, the differences between hybrid composite boards manufactured from both adhesive increased with the increase of green tea content. On the other hand, high correlations were found between dynamic MOE and static bending strength performances, it was concluded that static bending strength performances could be estimated from the dynamic MOE, except for a few hybrid board types with large variations.

Detection of Cavities Behind Concrete Walls Using a Microphone (마이크로폰을 이용한 콘크리트 벽체 배면의 공동 탐사)

  • Kang, Seonghun;Lee, Jong-Sub;Han, WooJin;Kim, Sang Yeob;Yu, Jung-Doung
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.19-28
    • /
    • 2022
  • Cavities behind concrete walls can adversely affect the stability of structures. Thus study aims to detect cavities behind concrete structures using a microphone in a laboratory model test. A small-scale concrete wall is constructed in a chamber, which is composed of a reinforced concrete plate and dry soil. A plastic bowl is then placed between the plate and soil to simulate a cavity behind the concrete structure. Leaky surface acoustic waves are generated by impacting the concrete plate using a hammer and are measured using a microphone. The measured signals are analyzed using natural frequencies, and cavity-free sections are evaluated. The test results show that the first natural frequency decreases at the cavity section due to the flexural vibration behavior of the plate. In addition, the amplitude corresponding to the first natural frequency decreases as the measurement location becomes farther from the cavity center and significantly decreases at the measurement locations near the rebars. This study demonstrates that a microphone may be useful to detect cavities behind concrete walls.

Evaluation of Serviceability and Flexural Performance for RC Hollow Slab by Hollow Ratio and Damping Ratio (중공율과 감쇠율을 이용한 RC 중공 슬래브의 사용성 및 휨성능 평가)

  • Jong Hoon Kim;Dong Baek Kim;Yong Gon Kim;Jae Won Lee;Jeong Ho Choi
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.930-935
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the stiffness reduction and damping ratio of reinforced concrete hollow slabs and to analyze their performance, and to study the effect of the damping effect of hollow bodies and the stiffness reduction on the serviceability of slabs. Method: Test specimen was made in a size of 0.6m*0.21m*3.6m to evaluate the vibration effect of the slab, and the hollow ratio was set in six steps from 0.0% to 30% to measure the change in rigidity and damping according to the change in the hollow ratio. Result: As the hollow ratio increases, rigidity decreases and the natural frequency decreases, but as the mass decreases, the natural frequency increases gradually. Since energy is hardly dissipated up to the hollow ratio of 20%, the hollow ratio should be reduced by 30%. Conclusion: It was found that the bending strength degradation of the slab with a hollow ratio of about 30% is minimized, but an appropriate natural frequency can be maintained, and a certain damping effect can be obtained.

Effect of Green Tea and Saw Dust Contents on Dynamic Modulus of Elasticity of Hybrid Composite Boards and Prediction of Static Bending Strength Performances (이종복합보드의 동적탄성률에 미치는 녹차와 톱밥 배합비율의 영향 및 정적 휨 강도성능의 예측)

  • Park, Han-Min;Lee, Soo-Kyeong;Seok, Ji-Hoon;Choi, Nam-Kyeong;Kwon, Chang-Bae;Heo, Hwang-Sun;Byeon, Hee-Seop;Yang, Jae-Kyung;Kim, Jong-Chul
    • Journal of agriculture & life science
    • /
    • v.46 no.2
    • /
    • pp.9-17
    • /
    • 2012
  • In this study, in addition to the green tea - wood fiber hybrid composite boards of previous researches, to make effective use of saw dust of domestic cypress tree with functionalities and application as interior materials, eco-friendly hybrid composite boards were manufactured from wood fiber, green tea and saw dust of cypress tree. We investigated the effect of the component ratio of saw dust and green tea on dynamic MOE (modulus of elasticity). Dynamic MOE was within 1.41~1.65 GPa, and showed the highest value in wood fiber : green tea : saw dust = 50 : 40 : 10 of the component ratio, and had the lowest value in 50 : 30 : 20 of component ratio. These values were 1.4~1.6 times higher than static bending MOE of wood fiber - saw dust - green tea hybrid composite boards, and were 2.0~2.9 times lower than those of green tea - wood fiber hybrid composite boards reported in the previous researches. From the results of correlation regression analyses between dynamic MOE and static strength performances, a very high correlation coefficients were obtained, therefore it was found that static bending strength performances can be estimated with a high reliability from dynamic MOE.