• Title/Summary/Keyword: Fire scenario

Search Result 240, Processing Time 0.026 seconds

A Study on the Early Response System Subway Cabin Arson Fire (지하철 차량 방화사고 초기대응에 관한 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu;Kim, Si-Gon
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.21-30
    • /
    • 2006
  • Since Daegu subway arson fire disaster in 2003, there have been several copycat crimes such as at Seoul Metro line number seven and Hongkong Chuiwan line cases. Oil and gas were used for fire propagation in most cases as in Daegu case and such fire could be expanded to a whole subway cabin within several minutes. The fire may eventually cause the whole subway system stop. Fire damage can be minimized when fire occurrence and diffusion are blocked by stages or isolated rapidly. This study suggests an effective early response system that separates passengers from fire and a real-time fire extinguishment program by stages. Based on the subway arson case studies, the early response scenario has been structured by three stages, i.e., confirmation of fire and damage, early fire extinguishment, and information dissemination and passengers evacuation.

Activation Conditions of Sprinkler Head Considering Fire Growth Scenario (화재성장시나리오에 따른 스프링클러 헤드의 작동조건)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.45-51
    • /
    • 2020
  • The aim of this study is to investigate the gas temperature and velocity during sprinkler activation considering the fire growth scenario based on the thermal response model of the sprinkler. The fire source is assumed to have time square fire growth scenarios with a maximum heat release rate of 3 MW. Eight types of standard and fast-response sprinkler heads with an operating temperature range of 65-105 ℃ and a response time index range of 25-171 m1/2s1/2 were adopted. The temperature difference between the gas stream and the sensing element of the sprinkler head decreased as the fire growth slowed down, and the RTI value decreased. The overall gas temperature and velocity conditions predicted using the FDS model at sprinkler activation were in reasonable agreement with those of standard test conditions of the sprinkler head response. However, the sprinkler head could be activated at lower limits of gas temperature and velocity under the current test conditions for a slowly growing fire scenario.

A Study on the Improvement of Fire Evacuation Scenario Using Delphi Technique -Focus on The Mobile Application and psychology- (델파이 기법을 활용한 화재피난 시나리오 개선 연구- 모바일 어플리케이션과 재실자 심리를 중심으로 -)

  • Lee, Sang ki;Kim, Sung Hyun
    • Journal of Service Research and Studies
    • /
    • v.12 no.2
    • /
    • pp.23-37
    • /
    • 2022
  • Based on the service scenario proposed by the existing Kim Tae-wan (2018) who can safely evacuate inmates with the help of a mobile application linked to a fire detection system in the event of a fire, the final purpose of this study is to develop the scenario by incorporating more realistic scenarios with mobile stimuli that can help them escape or act through the Delph In addition, to make the scenarios produced more realistic considering the structure and copper lines of a typical building, expert scenario verification and Delphi technique were applied to exclude unnecessary or impractical aspects of the existing scenarios. The results of the second Delphi survey showed that the primary psychology that could be seen at the time of the fire alarm were doubts, safety concerns and alarm, and the results of the second Delphi survey were analyzed, and the satisfaction of the content adequacy (CVR), convergence, and consensus was derived. Finally, this was applied to create a scenario in which a mobile application was assisted to evacuate the fire response phase. This study will allow the use of methods to increase the evacuation rate of those who are in the event of a fire.

The Study of Training Scenario for the KA-32T Helicopter Simulator (KA-32T 헬리콥터 시뮬레이터를 위한 훈련 시나리오 연구)

  • Jeong, Ji-Hoon;Kang, Seung-On;Lee, Ki-Hak;Park, Yong-Jin;Ko, Kang-Myung;Ham, Dae-Young;Lee, Dong-Ho;Jun, Hyang-Sig;Choi, Hyung-Sik
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.2
    • /
    • pp.28-35
    • /
    • 2008
  • The purpose of this study is to develop a training scenario for KA-32T helicopter simulator. First, the concept of training scenario are classified into training elements and training information. Secondly, the training elements are defined according to the property of each element: flight phase, situation, and environment. The main mission of KA-32T on the operation of KFS(Korea Forest Service) is the forest fire extinguishment mission, and it is divided into the two disciplines: water supply and water discharge. Finally the mission scenario for two disciplines are defined and developed as the combination of the normal procedures of training scenario and the mission procedures.

  • PDF

A Study on the Range of Damage Effects of Benzene Leakage Accidents using the KORA Program (KORA 프로그램을 활용한 벤젠 누출사고 피해영향범위에 관한 연구)

  • Cha, Jeong-Min
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.112-120
    • /
    • 2019
  • Benzene is a class 4 hazardous material according to the Act on the Safety Control of Hazardous Substances. This study qualitatively evaluated the damage size of a "toxic" accident and "pool fire" accidents based on benzene in a virtual scenario of a fire and leakage accident during unloading at a port facility. The KORA program was used as an evaluation method, which is supported as a universal program by the National Institute of Chemical Safety. The range of damage effects of a benzene-induced fire and leakage accident was predicted. In the case of toxic damage range, the accident's damage effect range for the "worst case scenario" was reduced by up to 5.11% with a decrease in the size of the leakage hole. In the case of the leakage time, the damage effect range increased to 145.12% with a 10 min leakage time compared to that of a 5 min leakage time and went up to 20 min (212.29%) with a 20 min leakage time. In the case of pool-fire-induced damage, the damage effect range by radiant heat in the "worst case scenario" was 228.8 m in radius from the center of the handling facility. In the "alternative scenario," the damage effect range by radiant heat was reduced by up to 8.26% compared to that in the "worst case scenario" since the size of the leakage hole was decreased by reducing the cross-sectional area of the pipe.

Study on Dispersion Characteristics for Fire Scenarios in an Urban Area Using a CFD-WRF Coupled Model (CFD-WRF 접합 모델을 이용한 도시 지역 화재 시나리오별 확산 특성 연구)

  • Choi, Hee-Wook;Kim, Do-Yong;Kim, Jae-Jin;Kim, Ki-Young;Woo, Jung-Hun
    • Atmosphere
    • /
    • v.22 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • The characteristics of flow and pollutant dispersion for fire scenarios in an urban area are numerically investigated. A computational fluid dynamics (CFD) model coupled to a mesoscale weather research and forecasting (WRF) model is used in this study. In order to more accurately represent the effect of topography and buildings, the geographic information system (GIS) data is used as an input data of the CFD model. Considering prevailing wind, firing time, and firing points, four fire scenarios are setup in April 2008 when fire events occurred most frequently in recent five years. It is shown that the building configuration mainly determines wind speed and direction in the urban area. The pollutant dispersion patterns are different for each fire scenario, because of the influence of the detailed flow. The pollutant concentration is high in the horse-shoe vortex and recirculation zones (caused by buildings) close to the fire point. It thus means that the potential damage areas are different for each fire scenario due to the different flow and dispersion patterns. These results suggest that the accurate understanding of the urban flow is important to assess the effect of the pollutant dispersion caused by fire in an urban area. The present study also demonstrates that CFD model can be useful for the assessment of urban environment.

A Two-Stage Stochastic Approach to the Artillery Fire Sequencing Problem (2단계 추계학적 야전 포병 사격 순서 결정 모형에 관한 연구)

  • Jo, Jae-Young
    • Journal of the military operations research society of Korea
    • /
    • v.31 no.2
    • /
    • pp.28-44
    • /
    • 2005
  • The previous studies approach the field artillery fire scheduling problem as deterministic and do not explicitly include information on the potential scenario changes. Unfortunately, the effort used to optimize fire sequences and reduce the total time of engagement is often inefficient as the collected military intelligence changes. Instead of modeling the fire sequencing problem as deterministic model, we consider a stochastic artillery fire scheduling model and devise a solution methodology to integrate possible enemy attack scenarios in the evaluation of artillery fire sequences. The goal is to use that information to find robust solutions that withstand disruptions in a better way, Such an approach is important because we can proactively consider the effects of certain unique scheduling decisions. By identifying more robust schedules, cascading delay effects will be minimized. In this paper we describe our stochastic model for the field artillery fire sequencing problem and offer revised robust stochastic model which considers worst scenario first. The robust stochastic model makes the solution more stable than the general two-stage stochastic model and also reduces the computational cost dramatically. We present computational results demonstrating the effectiveness of our proposed method by EVPI, VSS, and Variances.

A Study on the Fire Safety of a Hybrid Composite Train Carbody (하이브리드 복합재 철도차량 차체의 화재 안전성 평가연구)

  • Kim, Jung-Seok;Lee, Duk-Hee; Jung, Woo-Sun;Cho, Sea-Hyun
    • Composites Research
    • /
    • v.21 no.4
    • /
    • pp.1-6
    • /
    • 2008
  • This paper explains fire safety tests of a hybrid composite train carbody with carbon/epoxy sandwich bodyshell and stainless steel underframe. In this study, a large scale mock-up was used to evaluate the fire safety of the composite train carbody. The test was conducted to the bare composite carbody mock-up without interior facilities and the fully equipped one. Tile fire propagation and temperature distribution of the carbon/epoxy bodyshell and the glass phenol interior panels was evaluated under the real fire accident scenario. The test scenario was based on the DaeGu subway fire accident. From the tests, both the surface temperature of the interiors and the composite bodyshell wore lower than tile ignition temperature. In addition, the fire spread along the surface of the interiors and bodyshell was not occurred.