• Title/Summary/Keyword: Fire growing rate

Search Result 21, Processing Time 0.032 seconds

Experiment and Analysis of Real-Scale Fire Test for Establishment of Design Fire in Building Structures (건축구조물의 설계화재정립을 위한 실규모 화재실험 및 분석)

  • Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.119-120
    • /
    • 2014
  • In this study, we looked into the method to establish fire growth rate by buildings use for growing fire at the beginning of a fire considering the characteristics of the combustibles in a performance-based design. Actual conditions survey and literature review were carried out for the fire load and exposed surface area of combustibles to establish design fire by domestic building use. As a results, a simplified prediction equation of fire growth rate which depends on fire load and weight of combustibles could be derived by calculating the relation between the fire load and the fire growth rate of an initial fire through investigation of combustibles by domestic building use.Also, as a result of analyzing the placement of combustibles and location of the ignition source, it was found that the influence of the materials of the combustibles and the materials of the combustibles adjacent to the ignition source is big. Though 4 different experiments were carried out for the evaluation, the result of comparing the findings with those of FGR model showed that the fire growth rate was similarly derived.

  • PDF

A Study on the Correlation between Fire Statistics and GNI(Gross National Income) (국민소득과 화재발생 건수의 상관관계에 관한 연구)

  • Choi, Jin-Man;Choi, Jae-Sung;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.4
    • /
    • pp.147-152
    • /
    • 2009
  • As a results of comparing with fire occurrences and gross national income(GNI), annual fire increasing rate has been 5.6%, and that of GNI has been 11% for the past 55 years. As GNI shows 5.4% higher than fire occurrences, economy growing rate is faster than that of fires. In addition, study has been done every 10 years from 1950's to 2000's. Fire occurrences increase twice as much annually and GNI increases above 3.3 times as much.

A Study on the combustible materials Combustion Characteristics in residential facilities fire behavior prediction (주거시설 화재성상예측을 위한 가연물 연소특성에 관한 연구)

  • Kim, Dong Eun;Kim, Gi Hyeon;Seo, Dong Goo;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.103-104
    • /
    • 2013
  • As a result of experimenting 6 loading combustibles in domestic residential facilities by using Furniture Calorimeter, values of 2,391.26kW were appeared from sofas, 1,891.80kW from drawers, 1,778.95kW from mattress, 1,104kW from chairs, 291kW from tables, and 135.09kW from TV. Also, if applying α value of fire growing rate by classifying fire- growing speeds at NFPA 72 (National Fire Alarm Code 2007, Annex B), mattress can be defined as Ultra-Fast, sofa and drawers Fast, TV Slow, tables Slow, and chairs Medium.

  • PDF

A Study on the make Fire Scenario for Residential Facility Combustible Materials

  • Kim, Dong-Eun;Lee, Dong-Yeol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.6
    • /
    • pp.137-143
    • /
    • 2021
  • In the case of residential facilities, general fire scenarios cannot be applied. Becauseit is difficult to quantify due to the types of combustibles and various fire loads. Existing research conducting surveys of combustibles, but research on fire characteristics is insufficient. Therefore, in this study, an Excel macro that can be quantified by experimenting with the HRR experiments of sofa, drawer, mattress, chair, desk and TV, which are typical combustibles. As a result of experimenting 6 loading combustibles in domestic residential facilities by using a furniture calorimeter, values of 2,391.26kW appeared from the sofa, 1,891.80kW from the drawer, 1,778.95kW from the mattress, 1,104kW from the chair, 291kW from the desk, and 135.09kW from the TV. Also, by applying the α value of the fire growth rate by classifying fire-growing speeds at NFPA 72 (National Fire Alarm Code 2007, Annex B), the mattress can be defined as Very Fast, the sofa and drawer Fast, the TV Slow, the desk Slow, and the chair Medium.

A Study on the Combustion Characteristics of Biomass using Cone- calorimeter (I) : the Case of Maple Leaves, Gingko Leaves, Bush, Pine Needles (콘 칼로리미터를 이용한 바이오매스의 연소특성에 관한 연구(I) - 단풍잎, 은행잎, 덤불, 솔잎에 대해서 -)

  • Park, Byung-Hyun;Park, Duck-Shin;Cho, Young-Min;Park, Eun-Young;Lee, Cheul-Kyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.459-469
    • /
    • 2005
  • In recent years, concerns have been growing globally regarding greenhouse gases. Open burning of biomass causes emission of a number of greenhouse and other gases and substances. This paper studied an analysis on the characteristics of four types of biomass using duel type cone calorimeter. Cone calorimeter is widely used for assessing combustibility of materials in Europe. As a result, we evaluated several characteristics of biomass, such as heat released rate, smoke production rate, CO, $CO_2$ production and mass loss rate, and so on. $CO_2$ is currently responsible for over $60\%$ of the enhanced greenhouse effect, and may be the most important contributor to future. $CO_2$ production for biomass in the range of $1.74\~1.99kg/kg$ is similar to previous research conducted by Bhattacharya et al. (2002a).

Mortality in Pine Stand and Vegetation Recovery after Forest Fire (산불발생 후 소나무 피해 및 식생복원 실태분석)

  • Lee, Si-Young;Jun, Kye-Won;Lee, Myung-Woog;Chun, Kun-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.71-79
    • /
    • 2008
  • To find out the effect of the vegetation recovery and the problems of forest land, the researches of the mortality in pine stand and vegetation recovery have been carried out from the burned site. In area which is damaged by fire scar on crown and stem, rate of dead is higher. Where stand growing stocks were totally damaged by crown forest fire, most of vegetation was recovered by sprouts and planted seeds. Vegetation recovery power were depending on the condition of soil depth condition. For the artificial recovery, the damage happened by insects in the planted birches plantation. Rate of growth was somewhat different between Pinus densiflora and Pinus thunbergii in the plantation, because of individual growth rate.

Case Study of a Field Test for a Smoke Control System Using Sandwich Pressurization (샌드위치 가압을 이용하는 연기제어 시스템의 현장실험 사례 연구)

  • Kim, Jung-Yup;Ahn, Chan-Sol
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Amid the growing number of high-rise complex buildings in Korea, efficient smoke prevention technology in a fire is required and as an alternative of a mechanical smoke control system in high-rise buildings, the use of a smoke control system using sandwich pressurization has been on the rise. In such a system, the appropriate pressure difference and the data for designing the air supply and exhaust flow rate are necessary to prevent the spread of smoke and offer a tenable evacuation environment. As part of such effort, this paper presents a field test process and result after testing a building where such a smoke control system using sandwich pressurization has been installed. A ventilation rate of 6 cycles per hour were applied to simulate the air exhaust flow rate on a fire floor and the air supply flow rate on the floors above and below the fire floor. As a result of the system operation, pressure difference of approximately 260 Pa between the 12th floor of a fire and the 13th floor was generated. The over pressure of the experiment has a serious effect on the evacuation or fire compartment so that it is necessary to examine the improvement.

The Analysis of the effects of the platform screen door on the fire driven flow in The Deeply Underground Subway Station (대심도 지하역사에서의 화재시 플랫폼 스크린 도어에 의한 열, 연기 거동 영향 분석)

  • Jang, Y.J.;Kim, H.B.;Lee, C.H.;Jung, W.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.1984-1989
    • /
    • 2008
  • In this study, fire simulations were performed to analyze the characteristics of the fire driven flow and the effects of the platform screen door on the smoke flow in the station, when the fire occurred in the center of the platform. Soongsil Univ. station (line number 7, 47m in depth underground) was chosen which was the one of the deepest underground subway stations in the Seoul metro, SMRT. The parallel computational method was employed to compute the heat and mass transfer eqn's with 6 CPUs of the linux clustering machine. The fire driven flow was simulated with using FDS code in which LES method was applied. The Heat release rate was 10MW and The Ultrafast model was applied for the growing model of the fire source. The 10,000,000 structured grids were used.

  • PDF

Activation Conditions of Sprinkler Head Considering Fire Growth Scenario (화재성장시나리오에 따른 스프링클러 헤드의 작동조건)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.45-51
    • /
    • 2020
  • The aim of this study is to investigate the gas temperature and velocity during sprinkler activation considering the fire growth scenario based on the thermal response model of the sprinkler. The fire source is assumed to have time square fire growth scenarios with a maximum heat release rate of 3 MW. Eight types of standard and fast-response sprinkler heads with an operating temperature range of 65-105 ℃ and a response time index range of 25-171 m1/2s1/2 were adopted. The temperature difference between the gas stream and the sensing element of the sprinkler head decreased as the fire growth slowed down, and the RTI value decreased. The overall gas temperature and velocity conditions predicted using the FDS model at sprinkler activation were in reasonable agreement with those of standard test conditions of the sprinkler head response. However, the sprinkler head could be activated at lower limits of gas temperature and velocity under the current test conditions for a slowly growing fire scenario.

The Study on Fire Phenomena in The Deeply Underground Subway Station (대심도 지하역사에서의 화재현상 연구)

  • Jang, Yong-Jun;Kim, Hag-Beom;Lee, Chang-Hyun;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1773-1780
    • /
    • 2008
  • When the fire occur in the deeply underground subway station, the difficulties of passenger evacuation are expected because of many stairs to the exit. In this study, SOONGSIL-University station (7 line, 47m depth) is the one of the deepest subway stations of the each line in the Seoul metro. The numerical computational-simulation was performed for the fire driven flow in the subway station. Hot and smoke flow was analyzed from the simulation results. The proper plan of evacuation against fire was considered through the results. The fire driven flow was simulated using FDS code in which LES method was applied. The Heat Release Rate was 10MW and the ultrafast model was applied for the growing model of the fire source. The proper mesh size was determined from the characteristic length of fire size. The parallel computational method was employed to compute the flow and heat eqn's in the meshes, which are about 10,000,000, with 6cpu of the linux clustering machine.

  • PDF