• Title/Summary/Keyword: Fire facility

Search Result 447, Processing Time 0.023 seconds

A Study on the Fire Safety of Residential Facility Considering Grenpel Tower Fire (그렌펠 타워 화재를 고려한 주거시설 화재안전에 관한 연구)

  • Lee, Kyu-Min;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.69-70
    • /
    • 2017
  • Recently, The Building has became high rising and large scaling according to development of economy in domestic and other country, also the building has increased a variety of functions of insulation for warmth. and it has a symbol of economic growth, but it has risk factor for disasters such as fire. this hazards include not only general building but also residential building. Recently, Grenfell Fire that occurred in England has increased in combustion to the 24th floor of the 1st floor for 1 hour. it resulted in 80 deaths and 79 missing persons. In this study we suggest basic data of residential building for fire safety design related to domestic environment to analyze the problem of Grenfell Tower.

  • PDF

A Study on Fire and Evacuation in the Public Relations Room of Waste Treatment Facilities (폐기물 처리시설 홍보실내 화재 및 피난에 관한 연구)

  • Lee, Jae-Young;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.1
    • /
    • pp.17-22
    • /
    • 2021
  • The public relations room of the waste disposal facility is a space that can be visited by a large number of unevaluated personnel. Therefore, it is essential to design against fire, and research on fire and evacuation is essential. In this study, in order to evaluate the safety of the occupants in the event of fire and evacuation based on the life safety standards of occupants, the increase in risk due to heat, visible distance, and toxic gases on a plane 1.8m from the floor, which is the limit of breathing of the evacuee, over time. It was analyzed by location. As a result, the RSET of the P-01 exit was 93.0 seconds and the ASET was 272.6 seconds, the RSET of the P-02 exit was 45.8 seconds, the ASET was 147.7 seconds, the RSET of the P-03 exit was 106 seconds, and the ASET was 182.9 seconds.

u-Disaster Prevention System based Real-Time Fire Monitoring in a Building Facility (u-방재시스템 기반의 시설물 실시간 화재 모니터링)

  • Moon, Sung-Woo;Seong, Hyun-Jin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2011
  • The building infrastructures such as high-rise buildings, shopping malls, exhibition centers, etc. are becoming larger in magnitude and more complex in complexity. Considering a large number of tenants and visitors are staying in these facilities, it is upper most important to keep those in safe from fire outbreak. In this paper, a u-Disaster Prevention System has been presented to provide effective fire evacuation when fire breaks out in building infrastructures. The ubiquitous sensor network (USN) technology was applied to detect heat and smoke from fire outbreak. The information then is transmitted wirelessly to a host computer. The tenants and visitors residing in the facility can evacuate following the instruction that is displayed in LED sign boards of the u-Disaster Prevention System. A case study shows that the ubiquitous environment can help people evacuate faster in time, shorter in distance with the assistance of the u-Disaster Prevention System.

A Study on Assesment of Aalidity of Introducing of Design·Construction·Supervision Register Criteria Measures for Hazardous Materials Facilities (위험물시설의 설계·시공·감리업 등록제 도입에 대한 타당성 검토에 관한 연구)

  • Cha, Jung-Min;Lee, Yong-Jae;Kim, In-Beom;Hyun, Seong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.27-37
    • /
    • 2015
  • This study is to analyze current inadequate status of installing hazardous materials facilities, and to propose rational standards by researching validity for implementing registration for design, construction, supervision for installing fire safety facilities. By studying installation of registering designing, constructing, supervising industry on hazardous material facilities, professional and higher level of stability measures for national hazardous material facility was provided. For above reasons, necessity of institutionalizing of registering standards for construction and supervising industry became clear. Much more gradual institutionalization is needed for construction industry. Moreover, new national qualification should be reconsidered, in order to rebuttal the above and also to cultivate and acquire technical power.

A Study on the Effective Method of Fire Safety Management of Geriatric Hospitals (요양병원 소방안전관리의 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.83-88
    • /
    • 2016
  • Currently many geriatric hospitals have been built in Korea because increasing aging rapidly. However the increasing geriatric hospitals make the increasing safety accidents. Therefore this study is conducted by survey and face-to-face talk with the fire safety managers for analyzing safety problem of geriatric hospitals which number is twelve among 15 geriatric hospitals in the north of Chung-buk area. The result of this study is that geriatric hospitals are very old. Fire safety managers holding the fire safety license are a level 2 issued by the Korea Fire Safety Association(KFSA). And the fire safety inspection ability of them is normal (58%). Furthermore a fire safety budget ratio is 83% (A little) in the company yearly budget. And ratio having the fire inspection equipment in the building is 42% (A little) and 33% (Nothing). Satisfaction ratio of their duty is 66% and they also get stress from heavy duty and heavy responsibility. In conclusion, CEO needs to invest and interest the improvement of job performance, satisfaction ratio and fire safety facility. Also government needs the improvement of system to support and supervise the fire safety of geriatric hospitals consistently.

The Way for improvement of facility to strengthen accessibility of the site for fire department (소방대의 현장접근성 강화를 위한 설비의 개선방안)

  • Oh, Taek-Hum;Sung, Ja-Man;Pak, Chan-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.67-75
    • /
    • 2012
  • Because recently(July 14, 2011) fire occurred in the engine room of a moving taxi under Namsan Tunnel 1, 51 vehicles' driver and more than 250 passengers in the road tunnel were urgently evacuated with abandoned vehicles. Vehicle fires in Namsan Tunnel that day, Sufferers struggled to escape quickly difficult to escape the two-way by abandoned vehicles on the road and to fear many casualties by using vehicle fuel and combustible interior and the driver who is ignorant of vehicle accident continuous entered in the road tunnel had accessibility the site of fire department was more difficult. In this study, It is to investigate structure and basic materials, such as fire extinguish equipment and facilities for damage prevention and to analyze the problems and to plan improvement method of fire extinguish equipment, facilities for damage prevention and transportation facilities(Large traffic signs, Breaker, etc.) on the Namsan Tunnel that in the long-term plan is prepared to strengthen for accessibility of the site of fire department in case of Vehicle's fire.

Design of Large Cone Calorimeter for the Fire Study (화재연구를 위한 대형 콘 칼로리미터의 설계)

  • Lee, Eui-Ju
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.65-71
    • /
    • 2006
  • Some major properties such as a heat release rate have been measured experimentally for the validation of fire model and the clarification of fire phenomena as the study is more rigorous recently. Although the reduced-scale experiment also provides the basic data and the physical understanding in fire study, it is not enough to explain real fire problem directly because there is no exact analogy theory between a real fire and the reduced scale model. Therefore, large cone calorimeter have been built and used in a few foreign countries for the measurement of large scale fire. This paper addressed the theoretical background and the description of key features in the design of the facility. It will be a useful guide for implementation of the large scale cone calorimeter in the future.

Infrastructure of Propulsion Test Facility of Liquid Rocket (액체로켓 추진기관 시험설비 기반시설 고찰)

  • Cho, Namkyung;Kim, Sunghyuk;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.87-94
    • /
    • 2019
  • Liquid rocket propulsion test facility should provide for the interface condition installed on the upper level system for the test article. In addition, safety provision should be provided to be ready for accident such as explosion which can be occurred during development stage. For this purpose infra-structures of test facilities must be constructed so that stable combustion test can be performed and be guard against accidents. In this article, various aspects for infrastructures of propulsion test facilities are investigated including architecture and civil engineering aspects, test stand, room arrangements, interfaces among facilities, fire-fighting facilities, electrical power facilities.

A Study on the Safety Improvement of Mixed Acid Storage Facility through the Accident Investigation Applicated by RCA (혼산 저장설비 사고의 근본원인 분석을 통한 안전성 향상방안)

  • Kwon, Nam-Ho;Kim, Dong-Joon
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.47-54
    • /
    • 2018
  • Mixed acid is very reactive and highly corrosive. it has been causing many accidents in a electronic industry, a steel industry, and a chemical industry. Therefore, it is required that the high safety level for the acid storage facilities. In this study, we investigated the accident causes for resent leak accidents with Root Cause Analysis (RCA). The root causes analysed by RCA were categorized as nine divisions by the their characteristics. Furthermore, each nine divisions causes was applied to the PDCA model which are using at OHSAS 18001. It is suggested that the nine division with the root causes can be the essential items for the development of the safety management manual. It is helpful to the safety improvement of the acid storage facility.

A Study on the Evaluation of Evacuation Safety Function of an Elderly Care Hospital (일개 노인요양병원의 피난안전성능 평가에 관한 연구)

  • Kim, Jong-Bum;Kim, Ja-Ok;Back, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.9-19
    • /
    • 2010
  • Recently, Korea is constantly increasing its elderly care hospitals, and requires establishment of general evacuation plan considering old people's behavioral characteristics and physical states in emergency situations such as fire, and etc. In addition, because most of the facility users are patients under serious dementia and stroke, they feel difficulty evacuating by themselves, with differing evacuation time according to each walking status (bed, wheel chair, and various supplementary instruments), which is why it makes it difficult to have them all evacuate. This paper, in order to suggest data reference for designing on the basis of functionality, used various collected data utilizing Simulex to measure evacuation time through the model of elderly care hospital, a medical facility. During the study, several problems were found.