• Title/Summary/Keyword: Fire Service Act

Search Result 32, Processing Time 0.025 seconds

A Study on Proposals for Improving the Fire Protection Regulations for Nuclear Power Plants (원자력발전소 화재방호 규제 개선 방향에 관한 연구)

  • Ma, Jin-Soo;Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.116-122
    • /
    • 2010
  • The fire protection system of nuclear power plants shall be designed, constructed and operated, through a defense-in depth criterion to suppress the leakage of radioactivity to the outside and to allow the safety shutdown function when a fire occurs. In order to achieve these purposes, most of countries abroad operating the nuclear power plants keep up the integrated regulations, however we have two guidelines, the fire protection service act and the nuclear energy act, as mandatory requirements to apply to the fire protection systems in nuclear power plants. It has shown that USA, Canada and Japan which have long experience in operating nuclear power plants have regulations integrated technically for fire protection system of nuclear power plants. It is proposed that the things once verified the risk analysis of the fire hazard by the nuclear law in the design for fire suppression system in plants should be authorized by the fire protection service act as an exception.

A study on the Improvements of the Fire Officials' Employment (소방공무원 공개채용 시험과목 조정에 관한 연구)

  • Woo, Seong-Cheon
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.153-161
    • /
    • 2008
  • The duty of fire officials are very complicated and various that a subject replacement for the fire officials' public examination for service is being required. The purpose of this study is to investigate the actual conditions of the fire officials' public employment system and find out current problems of it, to reconsider the speciality of the examination based on them, and to suggest a subject replacement for the examination to evaluate the duty accomplishment ability. This study presents not only assuring the speciality of fire officials but also the desirable plans to execute the Fire Relating Act effectively by replacing introduction of political science with fire service administration and adding the Fire Relation Law which is more connected on the local fire officials public written examination for service with duty.

Vulnerability Analysis on Fire Service Zone using Map Overlay Method in GIS (GIS 기반 중첩기법을 이용한 소방서비스 취약지역 분석)

  • Lee, Seul-Ji;Lee, Ji-Yeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.91-100
    • /
    • 2011
  • Fire stations should be located in optimal location to act quickly in case of emergency and minimize damages as a public facility that protects life and property of local residents. Siting fire stations without regard for the accessibility and occurrence factors of an accident may provide fire service unequally. Therefore service analysis is necessary to reduce the blind spot of disaster and safety and to offer equal fire-service at this time. Especially fire stations can service more efficiently than before by reducing a more likely vulnerable area. This study suggests methods of mapping index of value that represents vulnerability of the occurrence of an accident and extracting service zone map of fire stations, as an initial research for offering efficient fire service. Geographical distribution mismatch between service zone map and vulnerability map is figured out and vulnerable area for fire service is defined by using map overlay method.

How Many Doctors and Paramedics Does Fire Service Need for Medical Direction in Korea? (소방 구급활동에 필요한 지도의사와 1급응급구조사의 수는?)

  • Uhm, Tai-Hwan;Yoou, Soon-Kyu
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.2
    • /
    • pp.37-43
    • /
    • 2008
  • Purpose : It was to improve medical direction system through presenting need of doctor and paramedic in Korean Fire Service. Methods : This study was conducted by applying demand coefficients(4 for doctor, 3 or 4.5 for paramedic) to some data on medical director, paramedic, ambulance from National Emergency Management Agency. Results : Number of medical director & paramedic were 4 & 1,217. Number of necessary doctor for medical direction was 64 or 28(in case of direct medical direction) & 16 or 7(in case of indirect medical direction). Number of necessary paramedic for direct medical direction was 492(in case of 35% ALS ambulance) & 1,062(in case of 50% ALS ambulance). Conclusions : To improve quality & efficiency of medical direction brought up need of amendment of the Emergency Medical Services Act to apply indirect medical control such as standing orders, protocol, case review.

  • PDF

A Study on Improvement of Domestic Airport Service for Rescue and Fire Fighting (국내 공항 구조 및 소방 업무 개선방안 연구)

  • Han, Jae-Hyun;Chung, Ki-Yeon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.4
    • /
    • pp.69-74
    • /
    • 2008
  • Aircraft fires due to accident at an airport may be under a special situation. An outstanding characteristic of aircraft fires is their tendency to reach lethal intensity within a very short time. In domestic aviation act, there are regulations related to services coping with the aircraft accidents within an airport. To cope aircraft fires, it is necessary to define clearly the regulations and standards about the services and related activities of rescue and fire fighting, and to keep the regulations and standards. The study has been performed on the basis of International Civil Aviation Organization (ICAO) Airport Services Manual of rescue and fire fighting. The objective of study is to suggest improvement methods for standards applicable to actual service practices of rescue and fire fighting by analyzing through the comparison of domestic and international regulations and standards.

  • PDF

A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System (법과 제도적 관점에서 본 소방특별조사의 개선방안)

  • Lee, Jae Wook;Jeong, Gi Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.545-552
    • /
    • 2021
  • Under the Act amended on August 4, 2011, a special fire-fighting investigation was conducted by the relevant person (owner, manager, oil refineries), and the responsibility was also given to the relevant person. Instead of directly entering all existing fire-fighting targets and investigating the maintenance and management status of fire-fighting facilities, the fire-fighting agency selects and visits some targets every year, checks the maintenance and management status of fire-fighting facilities, corrects them, and imposes fines, etc. Reasons for the introduction of the system were the establishment of a private autonomous correction system by strengthening the responsibility of officials, lack of firefighting professionals, possible corruption due to frequent public contact, and responsibility of fire agencies. However, many problems arose even after the introduction of a special fire investigation system. A special fire investigation, one of the fire safety systems, checks whether related public officials and especially fire officials are properly installed, maintained and managed in accordance with relevant laws. Special firefighting investigations were introduced as firefighting inspections at the time the firefighting law was enacted in 1958, and have undergone a revised process more than 30 times until recently. Firefighting Facility Installation, Maintenance and Safety Management Act", the existing firefighting inspection was changed to a special firefighting investigation and accepted. At the time of enactment of the Fire Service Act in 1958, a special firefighting investigation was introduced as a firefighting inspection, and until recently, more than 30 revisions have been made. In 2003, as the existing fire fighting system was divided into four laws, it was approved by changing the existing fire fighting inspection to a special fire fighting investigation in the "Fire Fighting Facility Installation, Maintenance and Safety Management Act".

A Study on Analysis of Installation on the Actual State and Improvement about a Descending Life Line (완강기의 설치 실태 분석 및 개선에 관한 연구)

  • Choi, Yong-Hyuk;Park, Sung-Jin;Kim, Tae-Gu;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.105-114
    • /
    • 2008
  • This study investigated problems found with the installation of a descending life line which is one of the compulsory fire escape apparatuses required by the revised "Fire Service Act" of 2006 for multi-use facilities and multistory buildings. It presents an analysis of the causes and improvement details for the problems classified by type of item. To achieve the purpose, the total 367 problem points are indicated. The problems of Installation are unsuitable window glass using the descending life line(34%), required passage device is not attached(23.7%), the installation location is with required operation(20%) and damaged descending life line(20%) were investigated. In particular, the study looks at the stress analysis range for cracking window glass which is required for people to escape in an emergency. People have questioned unsuitable window glass for using the descending life line among the problems with the installation. As a result of stress analysis, window glass thickness of the place where the descending life line is installed must be 3 or 6 mm. In addition, this study indicates substantial improvement measures for installing the descending life line so I will actually be used as a fire escape apparatus to protect human lives, and not just to formally meet the Fire Service Act.

A experimental Study on Insulation Breaking Fire Case of Starter Motor B Terminal (스타트모터 B단자 절연파괴 화재사례에 대한 실험적 연구)

  • Woo, Seung Woo;Park, J.M.;Hyun, B.S.;Nam, J.W.;Park, W.S.;Kim, J.P.;Cho, Y.J.;Goh, J.M.;Park, N.K.
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.55-62
    • /
    • 2019
  • In this paper, we introduce a case of a fire accident during parking of a large truck that is repeatedly occurring. The shape and location of the combustion and electrical singularity commonly found in other vehicle fire accidents could limit the starter motor as the ignition section. In addition, it was possible to confirm the electrical melting singularity that could act as a cause of ignition between the start motor B terminal and the start motor enclosure. By combining the above investigations and investigations, it was possible to estimate the electric fire expressed from insulation breaking of the starter motor B terminal, and by using the renewable starter motor comparison product mounted on the fire vehicle, an experiment was performed to reproduce the ignition process from the starter motor under specific conditions. So. It is hoped that this will raise awareness about vehicle fires, which can lead to large fires or casualties, share the risks of using starter motors for regeneration, and help in the rapid and accurate investigation of similar vehicle fires in the future.

Study on the Improvement of Inspection-Related Regulation of Fire Protection Systems and Equipment - Focused on the Fire Administration Process - (소방시설 자체점검 관계법령의 개선방안에 대한 연구 - 소방행정프로세서를 중심으로 -)

  • Lee, Jong Hwa
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.188-193
    • /
    • 2019
  • In the past, the risk of fire and the rate of fire occurrence has increased gradually as the quality of life improved due to rapid economic growth, and the government enacted Fire Prevention Act. The existing inspection method was revised considering the rapid increase in the number of fire-fighting objects(hereinafter referred to as specific fire-fighting objects) that require the installation of fire-fighting facilities, and has been applied to this day. On the other hand, unlike the rapid increase in specific fire-fighting objects and the development of fire prevention technologies, the scope of work and inspections by unsuitable inspectors caused a large fire accident, which required improvement of the related laws. This study evaluated, the Act on the relationship of firefighting facilities, which had been implemented previously to identify fire victims, save lives, secure independence of fire inspection agencies, and ensure the accuracy of fire prevention actions.

A study on the Improvement Method of the Report and Reward System on an Illegal Behavior of the Emergency Exit (비상구 불법행위 신고포상제도의 개선방안에 관한 연구)

  • Kim, Myeong Sik;Lee, Tae Shik;Cho, Won Cheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.49-59
    • /
    • 2012
  • The safety management of the emergency exit, by directly related to the $civil^{\circ}$Øs dead in the fire situation, have limited by which the fire station take the on-side and control-centered way of business processing, it is expect to the effects in which the citizen have to concern and to take part. From 2010 years in the back-ground, it is operated nationally the report and reward system on an illegal behavior of the emergency exit, it is happened to the unfit operating situation in the mission and direction of the system up which the exit paparazzi act with intent to receive the reward payments. The study suggests solution through analyzing the illegal emergency exit operation result of sixteen counties and the Seoul metropolitan from year 2010 to 2011. Firstly, the report destination is adjusted to the multiple use establishments and the large-scale multiple use facilities over the limit level is limited under five times the report events of the same people in the minor endorsement. And the fine incomes should be invested to the disaster prevention acting related with the exit. Secondly, for upgrade of the report accuracy, a reporter is received the possible information for the confirmation of an illegal act, has become to lead the pre-monitoring act which the reporter is can to take the safety education and to guide the information about season and vulnerable business location. Finally, considering the support way about the encounter facility, the fire officer is not happen to occur the repetitive report in the same place, is related to the volunteer service system the report acts, consider as the volunteer service time, and must support them to act as the disaster prevention volunteer.