• Title/Summary/Keyword: Fire Safety Controller

Search Result 23, Processing Time 0.028 seconds

A Study on Evacuation Safety of a Long-term Care Hospital (요양병원의 피난안전에 관한 연구)

  • Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.3
    • /
    • pp.389-393
    • /
    • 2023
  • In this study, We analyzed that evacuation characteristics of residents, fire safety standards, evacuation facilities and flame retardation, etc to increase the evacuation safety of a long-term care hospital. Therefore, In order to improve of evacuation safety in case of fire, We proposed that an increase in the number of care workers, education, training and an amendment to the law, a change of positions of fire safety controller.

A Study on the Prevention and Extinguishment of Fire in Vinyl Temporary Buildings for Agriculture and Fishery (농·어업용 Vinyl 가설건축물의 화재 예방 및 진압에 관한 연구)

  • Bong-Woo Lee;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.599-603
    • /
    • 2023
  • Analyzed in the NFDS, The average number of fires in vinyl temporary buildings is more than 1,000 in annually. And the number of deaths and injuries was around 30 people in every year. According to the National Fire Agency, There are 142,386 vinyl temporary buildings for Agriculture and Fishery, of which 4,720 are residential vinyl temporary buildings in illegally. Model house is subject to regulation in fire-related law. But, even though it's the same temporary building, Vinyl temporary building is not subject to regulation. For this reason, Vinyl temporary buildings are left in the blind spot of fire safety. Therefore, In this study, We propose that amend of Act on installation and management of firefighting systems, make of temporary fire safety controller, develop and apply of alarm system that is connected to a single-alarm smoke dretector, organize and operate volunteer fire brigade of the crop group to prevent and extinguish the fire.

Design and Fabrication of a Fire-damper using a Micro-Controller (마이크로컨트롤러를 이용한 소방용 댐퍼의 설계 및 제작)

  • Hwang, In-Gab;Han, Jae-Gil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.2
    • /
    • pp.89-93
    • /
    • 2006
  • Recently as a people recognize a safety more about a high and large buildings the importance of a fire-damper which supplies fresh air into the building in case of fire increases greatly. Therefore, in this paper a fire-damper using a micro-controller is designed and fabricated. In the design of fire-damper a pressure sensor is modeled as a capacitor and the p-spice is used as a circuit simulator PIC16F72 is used as a micro-controller to drive a pressure sensor and to display a pressure value from the pressure sensor and to drive a motor to open and close a damper. A photo-coupler is used to protect a motor from a overcurrent.

A Study on Railway Vehicles Fire Detection using HMI Touch Screen (HMI 터치스크린을 이용한 철도차량용 복합화재수신기 개발 연구)

  • Park, In-Deok;Kim, Chang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.38-43
    • /
    • 2016
  • Recent social needs for promoting traffic safety increased and the demand social security in economic, increasing the demand for environmentally friendly rail transport. In particular, when train express such as to secure reliability KTX(Korea Train eXpress) from potential disaster(fire) in the train operation caused by the train express running has been very important. Railroad fire extinguishing system is operated to fire exploding before reaching the flashing point more important than early to quickly detect because of CAN(Controller Area Network) communication to fire suppression and fire receiver, interface, fire fighting equipment from HMI((Human Machine Interface) and fire high-performance to research and development for intelligent composite fire receiver is required.

Development of VR Fire-extinguishing Experience Education Contents Using UX Design Methodology (UX 디자인 방법론을 적용한 VR 소방체험 교육콘텐츠 개발)

  • Chung, Yoo-Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.3
    • /
    • pp.222-230
    • /
    • 2017
  • The Ministry of Public Safety and Security plans to expand fire safety education infrastructure to provide customized fire safety education, spread fire safety culture and develop a tailored fire safety education system as a part of the 2016 Citizens' Safety Improvement Policy. This study has also been designed to improve safety problems in the Republic of Korea. Even though safety education has been given, citizens aren't still able to experience a close-to-real situation. In addition, their understanding and satisfaction with the curriculum are very low. Therefore, this study offers VR fire-extinguishing experience education contents as an effective alternative. With a goal of having the participants experience fire extinguishing and evacuation drill in a virtual space, this program has the following advantages: i) safe fire-extinguishing experience; ii) UI to create fun ; iii) useful in fire-extinguishing education; iv) budget saving. we configure the VR fire experience system structure and hardware by applying UX design methodology. We also develop for VR-specific motion recognition plug-in and controller that can be feeling in HMD environment.

The Development of a Functional Pressure Controller in Smoke Management Systems for the Fire Safety of Buildings (화재시 제연 및 피난을 위한 기능성 차압 조절장치 개발에 관한 연구)

  • Jung, Ki-Chang;Kim, Jeong-Hun;Lee, Jung-Yun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.44-48
    • /
    • 2004
  • The smoke and toxic gases generated from the building fires are proved to cause human death. Therefore, the necessity and significance of smoke control have been emphasized, and lots of studies for developing improved smoke management system have been carried out. In this study, the experiments were conducted to evaluated a function and performance in newly developed smoke management system using mechanical pressurization. As a result of this experiment, the differential pressure was 40Pa${\sim}$60Pa and the air velocity through the door was 0.7m/s between safety zone and fire zone. The functional pressure control equipment which could make proper pressure and maintain differential pressure between safety zone and fire zone was developed. And it will give a lot of helps to evacuation activity for peoples in building and fire fighting.

Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire (고양종합터미널화재 시 소방시설의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.95-107
    • /
    • 2018
  • This study analyzed the working conditions of the fire protection system in the Goyang Bus Terminal fire based on the fire investigation results. The results were as follows. First, extinguishing using an indoor fire hydrant was not attempted immediately after the fire burned the ceiling urethane foam. Second, a sprinkler alarm valve was turn off and did not work in the repair work space of the 1st basement. On the other hand, the sprinklers in the $2^{nd}$ basement, $1^{st}$ floor, $2^{nd}$ floor, and $3^{rd}$ floor worked and prevented the fire from moving to stories other than the $1^{st}$ basement. Third, although an exit light worked normally, it was not installed in the exit from the waiting room in the $2^{nd}$ floor to the bus stop. This resulted in many casualties. Fourth, although a fire receiver sent an electrical signal to the fan controller of the smoke control system, it was treated manually in the fan controller and the fan in the $2^{nd}$ floor did not work.

Integrated Command System for Firefight Satety in Special Disaster Area (특수재난현장 진압대원의 안전을 위한 통합 지휘시스템에 관한 연구)

  • Roh, Tae-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.98-108
    • /
    • 2015
  • An integrated command system is critical for the safety of firefighters and effective work in the headquarters of a special disaster areas such as natural disaster or large man-made hazard. The integrated command system requires environmental information such as temperature, humidity, and $CO_2$ levels, as well as personal physical information such as pulse and air respirator levels. An Analog to Digital Converter (ADC) chip converts sensed information into digital signals, and a Micro Controller Unit (MCU) transmits the digital signals to a transmission board using serial communication through a Serial Peripheral Interface (SPI). The digital signals are saved in a transmission board and transmitted to the integrated command system by a Radio Frequency (RF) unit. The location of fire-fighters in a building are determined using a gyro sensor and an inertial sensor. The collected information is applied to the integrated command system for firefighter safety and to ensure that they can effectively carry out their duties. Tthis study theoretically and experimentally investigated the technologies of RF transmission, indoor position, and an integrated command system that supports decision making using the transmitted information.

Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로-)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.57-66
    • /
    • 2018
  • A sports center fire in Jecheon that caused 29 deaths and 40 injuries was analyzed based on initial response and management in order to investigate the causes of the casualties. The aspects of initial response included delay of reporting 119, not being guided to the exit for the body scrubber on the $2^{nd}$ floor for escape, opening the fire doors of the exits on the $1^{st}$ floor and $3^{rd}$ floor, not closing the fire door of the main stairs on the $3^{rd}$ floor, and not doing an emergency broadcast. The management aspects included closing the alarm valve of the sprinkler system on the $1^{st}$ floor, starting-stop of the fire pump controller, neglecting leakage of water and electricity between the false ceiling and ceiling in the parking lot, hiding the exit light in the ladies bathroom lounge on the $2^{nd}$ floor and piling up things in the exit, neglecting the button of an automatic door on the $2^{nd}$ floor, conventional fire safety management, insufficient inspection of fire equipment, and not working fire shutters and smoke exhaust windows.

Research for Signal Interfaces between DOORS of DRIVERLESS TRAIN and PSD Control (무인운전 차량의 도어 및 PSD 제어 신호에 대한 연구)

  • Lee, Hee-Chang;Kim, Dong-Il;Chun, Sang-Hun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.857-865
    • /
    • 2010
  • Recently the demand of the driverless rolling stock is increasing with advancement of the stable communication technique and control technique. The automatic train operating system has advantages which takes low operating cost and is able to dispose elastically in demand. Beside it provides high safety and effectiveness because it will be able to control power, signal and communication system from Operation Control Center and the safety and effectiveness are high. The establishment of PSD, Platform Screen Door, is advanced in the goal which is passenger safety, fire protection, noise and dust reduction etc. When but, two advanced systems also have risks of operation delay and accident when two systems are not controlled smoothly. Thus, I'll introduce control method between onboard controller, door control unit in rolling stock and PSD controller to help system design.

  • PDF