• Title/Summary/Keyword: Fin thickness

Search Result 119, Processing Time 0.023 seconds

A study on the performance of the finned tube heat exchanger affected by the frosting using CFD tool (전산해석을 이용한 착상이 핀튜브 열교환기 성능에 미치는 영향에 관한 연구)

  • Kim, Sung-Jool;Choi, Ho-Jin;Ha, Man-Yeong;Bang, Seon-Wook
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2738-2743
    • /
    • 2008
  • We conducted a study by computational simulation about the effects of frost thickness on the pressure drop and heat transfer characteristics as whole heat exchanger configuration changes. In order to perform the analysis for validation, we assumed that frost properties have constant values and the frost layers that are formed on the fin and tube surfaces are uniform. In order to find the constant thermal conductivity of frost layer, a variety of frost thermal conductivities are performed in our work and compared with the results by Lee et al. [4] and Yang et al. [5] proposed many experimental data about the 2-rows and 2-columns finned tube heat exchanger. The numerical results agreed well with the experimental data when frost conductivity is 0.07W/mK. After the validation had performed, we applied this procedure to the finned tube heat exchanger of domestic refrigeration and investigated the thermo-hydraulic characteristic of the heat exchanger affected by frost thickness according to the inlet velocities and temperatures of air considering the configuration change such as fin pitch.

  • PDF

Numerical Analysis on Cooling Characteristics of the Heat Sink for Amplifier (앰프용 히트싱크의 방열특성에 관한 해석적 연구)

  • Seo, Jae-Hyeong;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.947-951
    • /
    • 2015
  • The objective of this study is to numerically investigate the cooling characteristics of the heat sink as a cooling device for the amplifier. In order to analyze the heat transfer performances of the heat sink, the steady-state thermal model of the ANSYS software was used and analyzed with the fin thickness, fin pitch and fin number of the heat sink. As a result, the temperature at the junction of heat sink was decreased with the increase of fin thickness and fin number. In addition, the thermal resistances of the heat sinks were enhanced from $0.764^{\circ}C/W$ to $0.739^{\circ}C/W$ and $1.254^{\circ}C/W$ to $0.610^{\circ}C/W$, respectively, with the increase of the fin thickness from 1 mm to 3 mm and fin number from 9 to 20, respectively.

Numerical Investigation on the Thermal Performance of a Cooling Device for a CPV Module (고집광 태양광 모듈용 냉각 장치의 열성능에 대한 수치 해석적 연구)

  • Do, Kyu Hyung;Kim, Taehoon;Han, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • In the present study, the effects of the heat spreader thickness and the heat sink size on the thermal performance of a cooling device for a concentrating photovoltaic (CPV) module were numerically investigated. Numerical simulation was conducted by using the simulation tool ICEPAK, commercial software based on the finite volume method. Numerical results were validated by comparing the existing experimental data. The thermal performance of a cooling device, which consisted of a heat spreader and a natural convective heat sink, was evaluated with varying the heat spreader thickness and the heat sink size. The geometric configuration of the natural convective heat sink, such as the fin height, the fin spacing, and the fin thickness, was optimized by using the existing correlation. The numerical results showed that the thermal performance of the cooling device increased as the heat spreader thickness or the heat sink size increased. Also, it was found that the spreading thermal resistance plays an important role in the thermal performance of the cooling device which has the localized heat source.

Optimum Design of Vaporizer Fin with Liquefied Natural Gas by Numerical Analysis

  • Jeong Hyo-Min;Chung Han-Shik;Lee Sang-Chul;Kong Tae-Woo;Yi Chung-Seub
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.545-553
    • /
    • 2006
  • Generally, the temperature drop under $0^{\circ}C$ on vaporizer surface creates frozen dews. This problem seems to increase as the time progress and humidity rises. In addition, the frozen dews create frost deposition. Consequently, heat transfer on vaporizer decreases because frost deposition causes adiabatic condition. Therefore, it is very important to solve this problem. This paper aims to study of the optimum design of used vaporizer at local LNG station. In this paper, experimental results were compared with numerical results. Geometries of numerical and experimental vaporizers were identical. Studied parameters of vaporizer are angle between two fins $(\Phi)$ and fin thickness $(TH_F)$. Numerical analysis results were presented through the correlations between the ice layer thickness $(TH_{ICE})$ on the vaporizer surface to the temperature distribution of inside vaporizer $(T_{IN})$, fin thickness $(TH_F)$, and angle between two fins $(\Phi)$. Numerical result shows good agreement with experimental outcome. Finally, the correlations for optimum design of vaporizer are proposed on this paper.

Optimization of an Asymmetric Trapezoidal Fin Based on the Fixed Fin Base Height (고정된 핀 바닥 높이에 기준한 비대칭 사다리꼴 핀의 최적화)

  • Song, Nyeon-Joo;Kang, Hyung-Suk
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.1
    • /
    • pp.45-54
    • /
    • 2012
  • Optimization of the asymmetric trapezoidal fin with various upper lateral surface slope is made using a two-dimensional analytic method. For the fixed fin base height, the optimum heat loss, fin length and effectiveness are represented as inner fluid convection characteristic number, fin base thickness, fin base height, fin shape factor and ambient convection characteristic number. For this optimum procedure, the optimum heat loss is defined as 95% of the maximum heat loss from the fin. One of the results shows that optimum heat loss and effectiveness seems independent of the fin shape factor while optimum fin length decreases almost linearly as the fin shape factor increases.

Behavior of frost formed on heat exchanger fins (열교환기 휜에서의 착상 거동)

  • Kim, Jung-Soo;Lee, Kwan-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2334-2339
    • /
    • 2008
  • This paper proposes an improved mathematical model for predicting the frosting behavior on a two-dimensional fin considering the heat conduction of heat exchanger fins under frosting conditions. The model consists of laminar flow equation in airflow, diffusion equation of water vapor for frost layer, and heat conduction equation in fin, and these are coupled together. In this model, the change in three-dimensional airside airflow caused by frost growth is accounted for. The fin surface temperature increased toward the fin tip due to the fin heat conduction. On the contrary, the temperature gradient in the airflow direction(x-dir.) is small throughout the entire fin. The frost thickness in the direction perpendicular to airflow, i.e. z-dir., decreases exponentially toward the fin tip due to non-uniform temperature distribution. The rate of decrease of heat transfer in the airflow direction is high compared to that in the z-direction due to more decrease in the sensible and latent heat rate in x-direction.

  • PDF

A Study on the Heat Transfer in Radial Fin of Rectangular Profile (사각형(四角形) 단면(斷面)을 가진 반경(半徑)핀에서의 열전달(熱傳達)에 관(關)한 연구(硏究))

  • Kim, Kwang-Soo;Yim, Jang-Soon;Seoh, Jeong-Il
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.24-32
    • /
    • 1982
  • In this paper, temperature distributions in radial fin of rectangular profile for steady-state with no heat generation are obtained by one-dimensional analytical method, finite difference method and experiment respectively. Heat flow rate and fin efficiency from the fin model are obtained by analytical method. Consequently, temperature distributions in radial fin can certify that are similar to exact solution. From theoretical analysis, the effects according to heat flow rate and fin efficiency are related to variation of parameters which are fin thickness ${\delta}_o$, fin base temperature $T_o$, thermal conductivity K with same basic dimensions and the effects are studied and compared.

  • PDF

A Study on the Heat Transfer in Radial Fin of Hyperbolic Profile (쌍곡선 단면을 가진 반경휜에서의 열전달에 관한 연구)

  • Kim, Kwang-Soo;Seoh, Jeong-Il
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.3
    • /
    • pp.9-17
    • /
    • 1982
  • In this paper, temperature distributions in radial fin of hyperbolic profile for steady -state with no heat generation are obtained by one-dimensional analytical method, finite difference method and experiment respectively. Heat flow rate and fin efficiency from the fin model are obtained by analytical method. To compare the exact solutions obtained by theoretical analysis with the results obtained by finite difference method, cylindrical shape is selected. Particularly, equations of finite difference method for cylindrical shape with irregular boundary are rearranged and formulated. Consequently, temperature distributions in radial fin can certify that are similar to exact solutions. From theoretical analysis, the effects according to heat flow rate and fin efficiency are related to variation of parameters which are fin thickness ${\delta}_o$, fin base temperature $T_o$, thermal conductivity K with same basic dimensions and the fleets are studied and compared.

  • PDF

Numerical Analysis in Heat Transfer of a Triangular Fin (삼각휜 열전달의 수치해석)

  • Chun, Sang-Myung;Kwon, Young-Pil
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.3
    • /
    • pp.52-57
    • /
    • 1982
  • One-dimensional approximation for fin problems is widely used in current texts and industrial practice. The errors caused by this approximation is analysed for a longitudinal triangular fin by the numerical solution of two-dimensional fin equation. Two-dimensional solution is obtained by the finite element method and com pared with the one-dimensional esact solution. The results show that total heat transfer and fin efficiency are overestimated by the one-dimensional approximation. The factors which cause these errors are the Biot number (Bi) and the ratio of fin length to half the thickness (L/a). When Bi is smaller than 1.0 these errors are smaller than $10\%$, but when Bi is larger than 5.0 they are a few ten percents. Fin efficiency obtaned by one-dimensional and long fin assumption is valid only then Bi is small and L/a is large.

  • PDF

A Study on the Analysis of Bilateral Fin-Line Structure by Variational Method (변분법에 의한 Bilateral Fin-Line 구조의 해석에 관한 연구)

  • Lim Jae Bong;Lee Choong Woong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.1
    • /
    • pp.20-26
    • /
    • 1986
  • In this paper, the Bilateral Fin-Line structure is analyzed by Rayleigh-Ritz variational method including the effects of conductor thickness. Bilateral Fin-Line bandpass filters are realized at X-Band. Experimental results are in good agreement with the theory.

  • PDF