• 제목/요약/키워드: Film defect

검색결과 390건 처리시간 0.024초

Huge Enhancement of Magneto-optical Kerr Effect of One-dimensional Photonic Crystals with a Ferromagnetic Defect Layer

  • Mitsuteru Inoue;Arai, Ken-Ichi;Toshitaka Fujii;Masanori Abe
    • The Korean Journal of Ceramics
    • /
    • 제6권4호
    • /
    • pp.408-411
    • /
    • 2000
  • Although the rotation angle and its spectrum of the magneto-optical Kerr effect are physical quantities determined inherently by the material itself, we found that they can widely be designed by utilizing a one-dimensional photonic crystal with a ferromagnetic defect layer. By suitable choice of the film structure, the rotation angle at a designated narrow wavelength is resonantly enhanced up to as several hundred times larger as ordinary rotation angle of the magnetic. This is originated by the localization of light at the magnetic layer inside the film.

  • PDF

선천성 좌측 심낭결손증 [1례 보고] (Congenital Left Pericardial Defect: A Case Report)

  • 성시찬
    • Journal of Chest Surgery
    • /
    • 제15권1호
    • /
    • pp.129-135
    • /
    • 1982
  • Congenital pericardial defect is a rare anomaly, which was first described by M. Columbus in 1559. Four hundred years later the first clinical diagnosis was reported by Ellis et al. The congenital pericardial defect Is usually asymptomatic and Is found Incidentally at thoracotomy and autopsy, but it appears that partial absence of pericardium Is not Innocuous because of sudden death due to herniation of a portion of heart. We experienced congenital left pericardial defect in 20 year old female who was diagnosed as left ventricular aneurysm before operation. This patient complained of dyspnea on exertion and anterior chest discomfortness. Physical examination revealed Grade II pansystolic murmur on the 3rd and 4th intercostal space left sternal border. There were specific abnormal findings on the chest plain film, EKG, ultrasonography, and left ventriculography. On 9th July 1981, an operation was performed and found the left partial pericardial defect through which a large portion of left ventricle was herniated Into left pleural space. The method of operation was removal of adhesion and widening of the pericardial defect to avoid Incarceration. After operation, we observed marked Improvement of symptoms and disappearance of cardiac murmur.

  • PDF

독립성분분석을 이용한 TFT-LCD불량의 검출 (Detection of TFT-LCD Defects Using Independent Component Analysis)

  • 박노갑;이원희;유석인
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제34권5호
    • /
    • pp.447-454
    • /
    • 2007
  • 최근 TFT-LCD (Thin film transistor liquid crystal display)패널의 수요증가에 비례하여 공정상 발생하는 LCD 불량의 수도 증가하고 있다. LCD 불량은 배경화면과 미세한 밝기대비 차이를 가지는 패널상의 불균등한 영역으로서 크게 정형과 비정형으로 나누어지며 사람의 눈에 매끄럽지 않게 보여진다. 이러한 불량은 배경과의 대비 차이가 미세하여 기존의 임계수준 검출이나 윤곽선 검출로는 불량을 검출할 수 없다. 본 논문은 비정형 LCD 불량을 독립성분분석, 적응 임계수준 검출 그리고 왜도를 이용하여 검출하는 방법을 제시한다. 본 검출방법은 잡음이 심한 영상에 대해서도 대응력이 뛰어나며, 생산라인에서 성공적으로 적용된다.

특이값 분해를 이용한 편광필름 결함 검출 (Defect Inspection of the Polarizer Film Using Singular Vector Decomposition)

  • 장경식
    • 한국정보통신학회논문지
    • /
    • 제11권5호
    • /
    • pp.997-1003
    • /
    • 2007
  • 이 논문에서는 LCD에 사용되는 편광필름 영상에서 결함을 검출하는 방법을 제안하였다. 제안한 방법은 결함의 지엽적인 특징을 이용하는 것이 아니라 특이값 분해를 이용하여 영상의 전역적인 정보를 반영하는 방법이다. 편광필름 영상을 특이값 분해하고 특이값 중에서 첫 번째 특이값만을 사용하여 영상을 재구성하면 재구성한 영상에서 정상 부분의 화소값과 결함 부분의 화소값들은 서로 다른 특성을 나타낸다. 입력 영상과 재구성한 영상의 화소값 비를 구하고 확률론적 방법을 사용하여 결함을 검출하였다. 제안한 방법을 이용하여 여러 가지 결함을 갖는 편광필름 영상에서 결함을 검출한 결과 검출력이 매우 우수한 것으로 나타났다.

강유전체막의 CMP 연마 특성 (Chemical Mechanical Polishing (CMP) Characteristics of Ferroelectric Film)

  • 서용진;박성우;김경태;김창일;장의구;김상용;이우선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.140-143
    • /
    • 2003
  • BST thin films have a good thermal-chemical stability, insulating effect and variety of phases. However, BST thin films have problems of the aging effect and mismatch between the BST thin film and electrode. Also, due to the high defect density and surface roughness at grain boundarys and in the grains, which degrades the device performances. In order to overcome these weakness, we first applied the chemical mechanical polishing (CMP) process to the polishing of ferroelectric film in order to obtain a good planarity of electrode/ferroelectric film interface. BST ferroelectric film was fabricated by the sol-gel method. And then, we compared the structural characteristics before and after CMP process of BST films. We expect that our results will be useful promise of global planarization for FRAM application in the near future.

  • PDF

박막 패턴의 레이저 리페어 연구 (A Study of Laser Repair for Thin Film Pattern)

  • 강형식;홍성준;최종윤;홍순국;전태옥
    • 한국레이저가공학회지
    • /
    • 제1권1호
    • /
    • pp.39-44
    • /
    • 1998
  • Laser ablation system for microscopic defect in thin film pattern was developed in this study. For the varification of this study, several laser ablation tests were accomplished. The ablated shape of thin film and the surface of base glass were analyzed by use of microscopic tools and EPMA. After some tests of thin film, the specification of laser and optical unit(max. laser energy is 25mJ, wavelength is 532nm, Q-switched Nd-YAG laser, frequency is 20Hz, Auto-focus unit is LD type.)

  • PDF

Dichlorosilane Gas를 이용한 High Temperature Oxide Thin Film의 특성 (Characteristics of High Temperature Oxide Thin Film Using Dichlorosilane Gas)

  • 이승석;이석희;김종철;박헌섭;오계환
    • 한국진공학회지
    • /
    • 제1권1호
    • /
    • pp.190-197
    • /
    • 1992
  • In this study we have investigated physical and electrical properties of high temperature oxide (HTO) thin film using dichlorosilane (DCS) gas. This film had low etch rate and excellent step coverage, and its characteristics of Si-O bond were similar to those of thermal oxide. I-V curves also showed similar electrical properties to those of thermally grown oxide (SiO2) while time dependent dielectric breakdown (TDDB) results revealed 1/4 value of thermal oxide. However, defect density was measured to be much lower value than that of thermal oxide.

  • PDF

The effects of voltage of x-ray tube on fractal dimension and anisotropy of diagnostic image

  • Baik, Jee-Seon;Lee, Sam-Sun;Park, Kwan-Soo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제37권4호
    • /
    • pp.211-215
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the effect of the kV on fractal dimension of trabecular bone in digital radiographs. Materials and Methods: 16 bone cores were obtained from patients who had taken partial resection of tibia due to accidents. Each bone core along with an aluminum step wedge was radiographed with an occlusal film at 0.08 sec and with the constant film-focus distance (32 cm). All radiographs were acquired at 60, 75, and 90 kV. A rectangular ROI was drawn at medial part, distal part, and the bone defect area of each bone core image according to each kV. The directional fractal dimension was measured using Fourier Transform spectrum, and the anisotropy was obtained using directional fractal dimension. The values were compared by the repeated measures ANOVA. Results : The fractal dimensions increased along with kV increase (p < 0.05). The anisotropy measurements did not show statistically significant difference according to kV change. The fractal dimensions of the bone defect areas of the bone cores have low values contrast to the non-defect areas of the bone cores. The anisotropy measurements of the bone defect areas were lower than those of the non-defect areas of the bone cores, but not statistically significant. Conclusion: Fractal analysis can notice a difference of a change of voltage of x-ray tube and bone defect or not. And anisotropy of a trabecular bone is coherent even with change of the voltage of x-ray tube or defecting off a part of bone.

  • PDF

참조영상 기반의 COF 결함 검출 및 분류 시스템 (COF Defect Detection and Classification System Based on Reference Image)

  • 김진수
    • 한국정보통신학회논문지
    • /
    • 제17권8호
    • /
    • pp.1899-1907
    • /
    • 2013
  • 본 논문에서는 초미세 패턴으로 구성된 칩-온-필름(Chip-on-Film, COF) 패키징 작업에서 발생하는 결함들을 참조영상에 기초하여 효율적으로 검출하고 분류하는 시스템을 제안한다. COF패키징 제작 과정에서 발생하는 치명적인 결함은 개방(open), 일부개방(mouse bite, near open), 단락(hard short) 및 돌기(protrusion, near short, soft short) 등을 포함한다. 이러한 결함을 검출하기 위해서는 기존에 직접 육안으로 식별하거나 또는 전기회로 설계를 이용하는 방법을 사용하였다. 그러나 이러한 방법은 매우 많은 시간과 고비용이 요구되는 단점이 있다. 본 논문에서는 참조영상을 사용하여 효과적으로 결함유무를 판단하고 결함이 발생되는 경우에 결함의 종류를 4 가지 형태로 분류하는 시스템을 제안한다. 제안방식은 검사영상의 전처리, 관심영역 추출, 지역이진분석에 의한 이물 특징 분석과 분류 등을 포함한다. 수많은 실험을 통해, 제안된 시스템은 초미세 패턴을 가진 COF의 결함 검사 및 분류에 대해 기존의 방식에 비해 시간과 경비를 줄이는데 효과적임을 보인다.