• 제목/요약/키워드: Film Thickness

검색결과 3,889건 처리시간 0.035초

Shop Primer의 다중 노즐 분사 스프레이 패턴 인자와 도막두께의 상관관계에 관한 연구 (A Study on Correlation of Dry Film Thickness with Multi-Nozzle Spray Pattern of Shop Primer)

  • 윤원준;최민규;노영식
    • 대한조선학회논문집
    • /
    • 제47권5호
    • /
    • pp.743-749
    • /
    • 2010
  • Multi-nozzle spray painting procedure of the inorganic zinc shop primer was established in order to obtain uniform film thickness. The shop primer paint prevents the corrosion of steel block during shipbuilding. When the dry film thickness of shop primer is insufficient, rust will be generated on the steel block. Otherwise, thick coating of shop primer may be a problem of weld defect. So, it is important to obtain the uniform film thickness of shop primer. The uniformity of dry film thickness is affected by spray speed, distance from spray gun to target surface and overlapping span of spray path. In order to uniformly maintain coating thickness of shop primer, the coating procedure was established based on the correlation of shop primer spray variables.

경유 혼입을 고려한 엔진 메인 베어링의 유막거동에 관한 수치적 연구 (Numerical Analysis on the Oil Film Behavior of Engine Main Bearing Considering Dilution of Diesel Fuel)

  • 김한구
    • Tribology and Lubricants
    • /
    • 제26권4호
    • /
    • pp.240-245
    • /
    • 2010
  • This paper describes the influence on engine main bearing behavior of the oil film when the fuel is diluted on a diesel engine equipped with DPF system. Oil film pressure and the thickness is calculated in accordance to the fuel dilution. The calculation is based on the numerical analysis of the engine main bearing. As a result, the engine oil viscosity decreased as the fuel dilution increased. This led the increment of the maximum oil thickness pressure. Verification of the minimum oil film thickness settlement by the engine gas pressure and the fuel dilution was confirmed. Destruction possibility of the engine main bearing was foreseen when the engine speed was 2000 rpm with the fuel dilution 15% and the 5W40 engine oil.

ESTIMATION OF LOCAL LIQUID FILM THICKNESS IN TWO-PHASE ANNULAR FLOW

  • Lee, Bo-An;Yun, Byong-Jo;Kim, Kyung-Youn;Kim, Sin
    • Nuclear Engineering and Technology
    • /
    • 제44권1호
    • /
    • pp.71-78
    • /
    • 2012
  • In many semi-empirical analyses of flow boiling heat transfer, an annular flow is often assumed as a model flow and the local liquid film thickness is a key parameter in the analysis. This work considers a simple electrical conductance technique to estimate the local liquid film thickness in two-phase annular flows. In this approach, many electrodes are mounted flush with the inner wall of the pipe. Voltage differences between two neighboring electrodes for concentric annular flows with various liquid film thicknesses are obtained before the main experiments and logged in a look-up table. For an actual application in the annual flow, voltage differences of neighboring electrodes are measured and then corresponding local film thicknesses are determined by the interpolation of the look-up table. Even though the proposed technique is quite simple and straightforward, the numerical and static phantom experiments support its usefulness.

다중격자 다중차원 기법을 응용한 캠과 종동물의 비정상 상태의 유막특성 연구 (Study on the Transient EHL Fluid Film for the Dynamic Contact Behaviors between Cam and Follower with Multigrid Multilevel Method)

  • 장시열
    • Tribology and Lubricants
    • /
    • 제20권3호
    • /
    • pp.132-139
    • /
    • 2004
  • Many researches about the contacts between cam and follower have investigated EHL film thickness either without dynamic loading effect or only with curve fitting formula such as Dowson-Hamrock's, because including squeeze film effect makes it hard to obtain convergence and stability of computation. Therefore, inaccurate information about minimum film thickness without dynamic loading condition causes inappropriate design of cam profiles and wrong selection of cam and follower materials. In this work, computation tools both for kinematics and dynamics of valve train system of push-rod type and for fluid film thickness with elastic deformation on the basis of dynamic loading condition with multigrid multi-level method is developed. The computational results of minimum film thickness with the respects of both static and dynamic loading conditions are compared for the contact of flat follower over the entire cycle.

주조물(鑄造物) 접착후(接着後) Cement층(層) 후경측정(厚徑測定)에 관(關)한 실험적(實驗的) 연구(硏究) (An Experimental Study on Cement Film Thickness Between Casting Restorations and Preparation Walls.)

  • 박의원
    • 대한치과보철학회지
    • /
    • 제8권1호
    • /
    • pp.25-29
    • /
    • 1968
  • The purposes of this study were to measure the film thickness of zinc phosphate cement between the casting restorations and preparation walls. In addition, the differences between finger press and non press techniques after the castings were seated completely on the preparation by an automatic mallet until the cement set were studied. The results were as follows : 1) In full cast crown, the cement film thickness on the side wall was thinner than that on the other walls. 2) In 3/4 crown and inlay, the cement thickness was thinner than that in cast crowns. 3) The cement of great W/P ratio showed thinner thickness than that of little W/P ratio. 4) The continuous finger press after the castings were seated completely on the preparations had few influence on the cement film thickness.

  • PDF

SiOC 박막에서 박막의 두께와 유전율의 변화 (Correlation between the Thickness and Variation of Dielectric Conatant on SiOC thin film)

  • 오데레사
    • 한국정보통신학회논문지
    • /
    • 제13권12호
    • /
    • pp.2505-2510
    • /
    • 2009
  • SiOC 박막은 화학적 증착 방법에 의해 여러 가지 유량비를 다르게 하여 증착되었다. SiOC 박막에서 유전상수의 감소원인에 대하여 조사하고 샘플들은 박막의 두께와 유전상수사이의 상관성에 대하여 분석하였다. 증착한 샘플에서 박막의 두께는 굴절률에 비례하는 경향성이 있으며, 유전상수가 가장 낮은 샘플에서 두께는 감소되었다. 굴절률은 열처리 후 감소하였는데, 열처리 하면서 박막의 두께가 감소되었기 때문이다.

Zirconium Titanate Thin FIlm Prepared by Surface Sol-Gel Process and Effects of Thickness on Dielectric Property

  • Kim, Chy-Hyung;Lee, Moon-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권5호
    • /
    • pp.741-744
    • /
    • 2002
  • Single phase of multicomponent oxide ZrTiO4 film could be prepared through surface sol-gel route simply by coating the mixture of 100 mM zirconium butoxide and titanium butoxide on $Pt/Ti/SiO_2Si(100)$ substrate, following pyro lysis at $450^{\circ}C$, and annealing it at 770 $^{\circ}C.$ The dielectric constant of the film was reduced as the film thickness decreased due to of the interfacial effects caused by layer/electrode and a few voids inside the multilayer. However, the dielectric property was independent of applied dc bias sweeps voltage (-2 to +2 V).The dielectric constant of bulk film, 31.9, estimated using series-connected capacitor model was independent of film thickness and frequency in the measurement range, but theoretical interfacial thickness, ti, was dependent on the frequency. It reached a saturated ti value, $6.9{\AA}$, at high frequency by extraction of some capacitance component formed at low frequency range. The dielectric constant of bulk ZrTiO4 pellet-shaped material was 33.7 and very stable with frequency promising as good applicable devices.

$Moir\acute{e}$ Fringe에 의한 액막 두께 미소 변위 측정 연구 (A Study on the Small Disturbance Measurement of Liquid Film Thickness by $Moir\acute{e}$ Fringe)

  • 전홍신;김경훈
    • 한국분무공학회지
    • /
    • 제2권4호
    • /
    • pp.29-35
    • /
    • 1997
  • Liquid film thickness is measured by $moir\acute{e}$ topography which monitored liquid surface. $Moir\acute{e}$ fringe measurement techniques share the inherent simplicity found in optical interferometric techniques have the advantage of use over a greater range of displacement. $Moir\acute{e}$ fringe are the geometric interference patterns observed when two dense line grating are superposed. Light transmitted through a fixed line grating is deviated by the liquid film surface, producing a distored image of the grating. The $moir\acute{e}$ fringe produced by projection of this optically distored grating onto a second stationary grating permit visualization of the liquid surface and measurement of the liquid film thickness. This study measured the small amplitude of liquid film thickness to the $moir\acute{e}$ fringe pattern produced when spherical metal was dropped glycerin put)1 And the measurement of liquid film thickness flowing down an inclined plate are required to calculate the liquid slope in a position.

  • PDF

스퍼 기어 시스템의 음향 신호와 비 유막 두께(Specific Film Thickness)의 상관관계에 관한 실험적 연구 (Experimental Investigation to Establish Correlation between Specific Film Thickness and Sound Signals in a Spur Gear System)

  • 김종식;;이상권
    • 한국소음진동공학회논문집
    • /
    • 제24권8호
    • /
    • pp.643-650
    • /
    • 2014
  • Gear transmission system is widely applied in engineering. As the problem of contact fatigue, wear, lubrication failure etc, the condition of gear teeth contacts will be worse. The vibration and sound signals in the gear system will be affected by the some failures like scuffing, abrasive wear and spalling due to the deterioration of gear teeth surface. By studying the estimation of specific film thickness, measurement of reduction in tooth thickness, visual examination of wear mechanisms on the gear teeth and their effects on the statistical parameters of vibration and sound signals, the research obtained the satisfactory results on accessing the surface fatigue wear in a spur gear system. The paper utilizes the relationship between statistical parameters obtained from sound signals and Stribeck curve to confirm the hypothesis of dependency of surface fatigue wear, specific film thickness.

Secondary Phase and Defects in Cu2ZnSnSe4 Solar Cells with Decreasing Absorber Layer Thickness

  • Kim, Young-Ill;Son, Dae-Ho;Lee, Jaebaek;Sung, Shi-Joon;Kang, Jin-Kyu;Kim, Dae-Hwan;Yang, Kee-Jeong
    • Current Photovoltaic Research
    • /
    • 제9권3호
    • /
    • pp.84-95
    • /
    • 2021
  • The power conversion efficiency of Cu2ZnSnSe4 (CZTSe) solar cells depends on the absorber layer thickness; however, changes in the characteristics of the cells with varying absorber layer thickness are unclear. In this study, we investigated the changes in the characteristics of CZTSe solar cells for varying absorber layer thickness. Five absorber thicknesses were employed: CZTSe1 2.78 ㎛, CZTSe2 1.01 ㎛, CZTSe3 0.55 ㎛, CZTSe4 0.29 ㎛, and CZTSe5 0.15-0.23 ㎛. The efficiency of the CZTSe solar cells decreased as the absorber thickness decreased, resulting in power conversion efficiencies of 10.45% (CZTSe1), 8.67% (CZTSe2), 7.14% (CZTSe3), 3.44% (CZTSe4), and 1.54% (CZTSe5). As the thickness of the CZTSe absorber layer decreased, the electron-hole recombination at the grain boundaries and the absorber-back-contact interface increased. This caused an increase in the current loss, owing to light loss in the long-wavelength region. In addition, as the thickness of the CZTSe absorber layer decreased, more ZnSe was produced, and the resulting defects and defect clusters led to an open-circuit voltage loss.