• Title/Summary/Keyword: Field test data

Search Result 2,430, Processing Time 0.031 seconds

Field Validation of alternative extraction method for the determination of airborne MWFs (대체용매를 이용한 금속가공유 측정방법 타당성에 대한 현장평가)

  • Jeong, Jee Yeon;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.2
    • /
    • pp.96-101
    • /
    • 2009
  • The purpose of this study was to conduct the field validation of alternative method(ETM method) by using non-carcinogenic, and less toxic solvents than NIOSH (National Institute for Occupational Safety and Health) analytical method 5524 for measuring the airborne metalworking fluids in workplaces. We carried out the field validation test by using the exposure chamber, guaranteeing the air sampling homogeneously in a machining environment. The ETM mixed solvent presented the complete solubility of MWFs used in test field. Based on the field test data, the bias of the ETM method from reference method, NIOSH analytical method 5524, was from -7.0% to 5.1%. The overall uncertainty of the ETM nethod was 21.6%, which satisfied the NIOSH criteria for the sampling and analytical criteria.

Overload Criteria of Distribution Transformers Considering the Electric Consumption Patterns of Customers (수용가 전력 소비 패턴을 고려한 배전용 변압기 과부하 판정기준)

  • 윤상윤;김재철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.9
    • /
    • pp.513-520
    • /
    • 2004
  • In the paper, we summarize the result of the experimental research for the overload criteria of domestic distribution transformers considering the electric consumption patterns of customers. For the basic characteristic data of distribution transformer overload, the actual experiments are accomplished. The field data of loads are surveyed from sample transformers for analyzing the consumption pattern of customer load. The load data acquisition devices are equipped, and the algorithm of load pattern classification is applied. In addition to this efforts, various load pattern data. in past are gathered. Then the representative load pattern of each customer type in domestic is extracted. The final results of overload criterions are presented as tabular form through the results of experiments and survey are combined. The field test of the experiment results is peformed using the special manufactured transformers, which can measure both the load and top-oil temperature of transformer. Through this, we verify that the results of field test are similar to the laboratory one and the Proposed overload criteria can be effectively applied to the real system.

Comparative Study on Difference in Driver's Workload between Driving Simulator and Field Driving in Tunnel, Highway (드라이빙 시뮬레이터 주행과 현장주행시 운전자 반응 비교 연구)

  • Kim, Hyun Jin;Kim, Ju Young;Choi, Gyeong Im;Ju, Che Hong;OH, Cheol
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.139-145
    • /
    • 2017
  • PURPOSES : This study analyzed the difference in a driver's workload between using a driving simulator and field driving in tunnel, highway. METHODS : Based on the literature review, it was found that a driver's workload could be quantified using biosignals. This study analyzed the biosignal data of 30 participants using data collected while they were using a driving simulator and during a field test involving tunnel driving. Relative energy parameter was used for biosignal analysis. RESULTS : The driver's workload was different between the driving simulator and field driving in tunnels, highway. Compared with the driving simulator test, the driver's workload exhibited high value in field driving. This result was significant at the 0.05 level. The same result was observed before the tunnel entrance section and 200 m after the entrance section. CONCLUSIONS : This study demonstrates the driving simulator effect that drivers feel safer and more comfortable using a driving simulator than during a field test. Future studies should be designed considering the result of this study, age, type of simulator, study site and so on.

Comparative study of Dutchcone and piezocone test on soft ground (연약지반에 대한 기계식 및 전자식 콘관입시험 비교 연구)

  • 장병욱;김재현;김동범;윤상묵;원정윤
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.237-244
    • /
    • 2002
  • A comparative study of 134 mechanical (Dutch cone) and 9. electronic cone (Piezocone) penetration data from the southern part of Korea has been performed. In general, Dutch cone results may be different from piezocone results due to the difference in structure of the cones. Cone penetrometer test data were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986,1990) Cone factors of Dutch cone and piezocone test have empirically been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

  • PDF

A study on Automatic field Test Equipment with improved maintenance and environmental reliability

  • Lee, Seok-Min
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.3
    • /
    • pp.9-16
    • /
    • 2018
  • In this paper, I purpose one of the development methods for portable Automatic field Test Equipment(ATE) with VME form factor. Almost portable ATE have not used to standards form factor and they are connected by mechanical non-rigid general connectors and wire harnesses among the components. Furthermore, it is hard to reuse developed board. So, it decreases to reusability of developed board and it is hard to maintenance of ATE. Even those things have weakness for vibration and drop test especially in portable ATE. The XK9A1 ATE using VME form factor has environmental reliability through vibration, drop, temperature test. It consists of 5 developed board called the control board, the wire & wireless communication board, the power supply board, the load board and the mother board. It is connected by two wire harnesses between mother board and extern circular connectors. The control board send the data and address to other board though each 16-bit data and 20-bit address line. You can develop the function board what you want to using those data & address line when it comes to needing other function board.

The field-test of Power Quality Meter and Power Management System in order to verify the performance (PQM 및 PQMS 성능검증을 위한 실증시험)

  • Choi, Sun-Kyu;Song, Il-Keun;Kwon, Tae-Ho;Han, Jae-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF

Field Test Results of Terrestrial Digital TV in Korea (한국의 지상파 DTV 필드테스트 결과)

  • 목하균;서영우;황해섭
    • Journal of Broadcast Engineering
    • /
    • v.5 no.2
    • /
    • pp.140-158
    • /
    • 2000
  • Testing of terrestrial Digital TV(DTV) broadcasting in Seoul and Kyung-gi region was started in May 1999. Tasks of the committee for DTV technical evaluation were to implement test procedures for DTV transmitting systems, to analyze various technical aspects of DTV and to complete a field test. This paper summarizes the field test results. The field test vehicle was designed and constructed to measure field data. We chose over 200 test points to verify the receiving status of DTV signals and compared them with the analog TV signals at the same site. The results showed stable and satisfactory reception of DTV signals over 70%. The system performance index was over 80%.

  • PDF

Structural Performance of an Advanced Compsites Bridge Superstructure for Rapid Installation (급속시공용 복합신소재 교량상부구조의 구조 성능)

  • Ji, Hyo-Seon
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.1
    • /
    • pp.34-45
    • /
    • 2010
  • This paper describes the design, manufacturing process, testing, application, and assessment of capacity-ratings of the first all advanced composites bridge on a public highway system. In order to verify the bridge design prior to the field application, a sub-scale bridge superstructure was built and tested in the laboratory. The field load test results were compared with those of the finite element analysis for the verification of validity. To investigate its in-service performance, field load testing and visual inspections were conducted under an actual service environment. The paper includes the presentation and discussion for advanced composites bridge capacity rating based on the stress modification coefficients obtained from the test results. The test result indicates that the advanced composites bridge has no structural problems and is structurally performing well in-service as expected. Since these composite materials are new to bridge applications, reliable data is not available for their in-service performance. The results may provide a baseline data for future field advanced composites bridge capacity rating assessments and also serve as part of a long-term performance of advanced composites bridge.

  • PDF

Field monitoring of wind effects on a super-tall building during typhoons

  • Zhi, Lunhai;Li, Q.S.;Wu, J.R.;Li, Z.N.
    • Wind and Structures
    • /
    • v.14 no.3
    • /
    • pp.253-283
    • /
    • 2011
  • This paper presents the field measurement results of wind effects on a super-tall building (CITIC Plaza, 391 m high) located in Guangzhou. The field data such as wind speed, wind direction and acceleration responses were simultaneously and continuously recorded from the tall building by a wind and vibration monitoring system during two typhoons. The typhoon-generated wind characteristics including turbulence intensity, gust factor, peak factor, turbulence integral length scale and power spectral density of fluctuating wind speed were presented and discussed. The dynamic characteristics of the tall building were determined based on the field measurements and compared with those calculated from a 3D finite element model of the building. The measured natural frequencies of the two fundamental sway modes of the building were found to be larger than those calculated. The damping ratios of the building were evaluated by the random decrement technique, which demonstrated amplitude-dependent characteristics. The field measured acceleration responses were compared with wind tunnel test results, which were found to be consistent with the model test data. Finally, the serviceability performance of the super-tall building was assessed based on the field measurement results.

A Reliable Study on the Accident Reconstruction using Accident Data Recorder (사고기록장치를 이용한 교통사고재현에 관한 신뢰성 연구)

  • Baek, Se-Ryong;Cho, Joeng-Kwon;Park, Jong-Jin;Lim, Jong-Han
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.179-187
    • /
    • 2014
  • As an Accident data recorder (ADR) is a system to record a vehicle's status and dynamics information on the before and after of accident, Traffic accident investigation agencies and parts developers have a lot of interest to analyze an accident objectively and develop automotive safety devices by using real accident data, This study is to analyze an accident objectively and scientifically on the basis of traffic accident reconstruction with the use of output data of an event data recorder. This study is conducted double lane change test six times and slalom test one time as a field driving test and simulation. Based on the vehicle speed, the longitudinal and transverse acceleration, steering angle, driving path, and other kinds of information obtained from the field driving test, this study performed a simulation with PC-Crash program of reenacting and analyzing a traffic accident. The simulation was performed twice in the acceleration-steering angle input method and in the acceleration-driving path input method. By comparing the result of the field driving test with the results of the two simulations, we drew an analysis method with the optimal path reconstruction.