• 제목/요약/키워드: Field installation test

검색결과 276건 처리시간 0.026초

배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험 (A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment)

  • 조진태;김주용;이학주;김재한
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.

FIELD TEST INSTALLATIONS USING N$H_3$SENSOR AND VENTILATION RATE SENSOR FOR CONTINUOUS MEASUREMENT OF TOTAL AMMONIA EMISSION FROM ANIMAL HOUSES

  • Berckmans, D.;Ni, J.Q.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.393-402
    • /
    • 1993
  • Two field test installations are discussed. In the first one a new ammonia sensor and an accurate ventilation rate sensor are combined. They are installed in the exhaust chimney in a ventilated pig house. The relative humidity and the room temperature are measured as well. In the second one, an in situ NH$_3$longrightarrowNO converter with subsequent NOx analyser is also being added for accurate ammonia measurement . In this way , the continuous measurement of the total NH$_3$emission can be obtained , the performance of the NH$_3$ sensor can be evaluated, and the ammonia reduction techniques can be tested. The outputs of measurement are fed into a data acquisition system then to a PC in the laboratory. There has been realised the first test installation with which research on the new ammonia sensor is carried out. The primary research results are presented.

  • PDF

VLBI 상관서브시스템의 현장설치 및 시험결과 고찰 (INSTALLATION AND PERFORMANCE VERIFICATION OF VLBI CORRELATION SUBSYSTEM)

  • 오세진;노덕규;염재환;박선엽;강용우;오충식
    • 천문학논총
    • /
    • 제27권1호
    • /
    • pp.1-16
    • /
    • 2012
  • In this paper, we describe the installation of VLBI Correlation Subsystem (VCS) main product and its performance at the Korea-Japan Correlation Center (KJCC). The VCS main product was installed at KJCC in August 2009. For the overall performance evaluation of VCS, playbacks, Raw VLBI Data Buffer (RVDB) system, and Data Archive (DA) system were installed together. The VCS main product was connected between RVDB and DA, and the correlation results were put into the DA to confirm the normal operation of VCS 16 station mode configuration. The evaluation test was first performed with 4 station mode, same as the factory test of VCS main product. Based on the results of 4 station mode, the same evaluation test was conducted for 16 station mode of VCS. We found that the correlation results of VCS were almost similarly compared to those of the Mitaka FX Correlator. Through the test results, we confirmed that the problems such as spectrum errors, delay parameter processing module and field programmable gate array errors in antenna unit, which were generated at the factory test of VCS main product, were clearly solved. And we verified the performance and connectivity of VCS by obtaining the expected correlation results and we also confirmed that the performance of VCS was sufficient for real VLBI observation data in both 4 and 16 station modes.

공동주택 음원실 바닥의 하중 설치에 따른 중량충격음 특성에 관한 연구 (The Research of the Heavy-Weight Impact Sound Characteristic by Live load Installation on the Source Room)

  • 김경우;양관섭;손장열
    • 한국음향학회지
    • /
    • 제26권6호
    • /
    • pp.235-242
    • /
    • 2007
  • 공동주택의 바닥충격음 측정 및 평가는 주로 입주 전에 이루어지고 있으나 실제 충격음 발생은 입주 후 커튼과 가구와 같은 중량물이 설치되어 있는 조건이므로 입주 전 후 음원세대(음원실)와 수음세대(수음실)의 상황은 다르다고 할 수 있다. 본 연구에서는 음원실에 가구 등과 같은 하중 설치에 따른 중량충격음 변화정도를 파악하기 위하여 바닥충격음 시험동과 현장에서 활하중($200kg/m^2$) 설치 전 후의 음원실 바닥슬래브 하부 진동가속도레벨 및 수음실 충격음레벨 변화를 측정하였다. 측정결과 하중설치를 통하여 진동가속도레벨 및 충격음레벨이 다소 저감되었으나 큰 영향은 받지 않는 것으로 나타났으며, 슬래브의 공진주파수도 변화하지 않았다.

공공장소의 음풍경 재현을 위한 가상음장현장재현시스템 개발 (Virtual Acoustics Field Simulation System for the Soundscape Reproduction in Public)

  • 송혁;국찬;장길수
    • 한국소음진동공학회논문집
    • /
    • 제14권4호
    • /
    • pp.319-326
    • /
    • 2004
  • The soundscape is a novel attempt to offer comfortable sound environments at the urban public spaces by adding pleasant sounds and removing unagreeable ones. Most important factors to be considered therein are to determine what kind of sounds to offer and how to adjust them to the changing circumstances. But, installing, maintaining and adjusting the soundscape system directly in the field will ensue numerous problems as well as high costs. Thus, it is essential to devise a test method to analyse and verify the outcome before the actual installation in the field takes place. This study aims at devising the instrument system that enables to control. with a great ease, numerous variables. reproduce most agreeable sound sources, and can verify the effects on the virtual simulatory settings, which is named as Virtual Acoustic Field Simulation System (VAFSS).

초전도 MRI 마그네트 국산화 개발 (The Domestic Development of a Superconducting MRI Magnet)

  • 배준한;심기덕;고락길;진홍범;조전욱;하동우;오상수;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.121-124
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

스피커를 이용한 400km/h급 고속철도 소음저감용 방음벽 상단장치의 음향성능 시험방법에 관한 연구 (A study on the acoustic performance test method using speaker of a noise reduction device for noise reduction of the 400km/h class high-speed railroad)

  • 윤제원;김영찬;장강석;엄기영;장승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.625-629
    • /
    • 2014
  • For the purpose of the acoustic performance evaluation of noise reduction device(NRD) installed at the top of noise barrier for further decreasing of noise level of 400km/h class high-speed railroad(HEMU), the acoustic performance test method using speaker instead of really running railway vehicle was suggested in this paper. For this, noise source location and frequency spectrum of HEMU was analyzed through the field noise test. These data were used for the determination of speaker's installation positions and frequency correction values applied to the speaker noise source. And, 400 meters long NRD was installed at the site where HEMU will be running at a speed of 400km/h. Finally, the outdoor speaker test with and without NRD showed that this NRD could decrease noise level even more than 3dB(A). In the future, the acoustic performance results of NRD conducted with speaker test will be compared with that of field test for HEMU running at a speed of 400km/h.

  • PDF

뇌 임펄스를 이용한 현수애자의 내부결함 검출 (The Inner Defect Detection of Suspension Insulators by Lightning Impulse)

  • 송일근;곽희로
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권6호
    • /
    • pp.83-90
    • /
    • 1995
  • 본 논문에서는 자기체 현수애자 내부의 미세한 결함에 의한 관통사고 원인과 예방책을 제시하고자 PD(Partial Discharge)실험에 사용된 자기체 현수애자의 전계강도를 분석하였고, 상용주파 유중파괴 시험과 급준파 전압시험을 비교, 시험하였다. 이중 시료는 SEM(Scanning Electron Microscope)을 사용해서 단면촬영과 소재의 특성을 분석하였으며, 이종 물질간의 열팽창계수 차이로 인한 사고 진전 가능성이 큰 자기부와 금구류의 접착제로 사용하고 있는 포틀랜드 시멘트에 대하여 오토클래브 팽창도를 시험하였고, 사고 예방을 위한 내부결함 평가방법을 제시하였다.

  • PDF

USN를 위한 CAN 기반 적외선 온도감시 시스템 (Infrared Temperature Monitoring System based CAN for USN)

  • 김영동;오금곤;정원태;강원찬
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.11-17
    • /
    • 2007
  • 고제철설비 같은 매우 가혹한 환경 조건에서 뜨거운 철판의 온도를 측정하는 적외선 온도측정시스템을 개발하였다. POSCO 광양제철소 철판 압연공정에서 3개원간의 현장 테스트를 수행하였다. 현장 시운전에서 개발된 시스템의 신뢰성을 확인하였다. A2TPMI 센서의 비선형 방정식을 풀기위해 커브핏 방법을 통해 보정하고, 각 레인지당 $1[^{\circ}C]$이하의 정밀도로 25[msec]처리 속도를 확보하였다. 실험에서는 POSCO에서 받은 시험성적과 USN 기반에서 폴링방식을 통한 트래픽 모니터링을 통해 효과적인 온도감시 시스템임을 확인하였다.

13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석 (Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings)

  • 장정호;이동근;이흥호
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.