• Title/Summary/Keyword: Field Installation

Search Result 1,199, Processing Time 0.028 seconds

The Development of a Stereo vision algorithm for Height Measurement of Ball Peak Point of BGA Device (BGA 소자의 볼 정점 높이 측정을 위한 스테레오 비젼 알고리즘 개발)

  • Lee, Sang-Sin;Park, Young-Soon;Kim, Joon-Seek;Joo, Hyo-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.431-436
    • /
    • 2005
  • In this paper, We proposed the stereo image modeling using 2-dimensional images captured by the high resolution cameras to inspect the ball defects of BGA(Ball Grid Array) device. The proposed algorithm consists of the package/ball area extraction part, the FOV(Field of View) calibration part, the top point matching part, and ball height measurement part, In the package/ ball area extraction part, the package and ball areas are separately extracted in a left and right image by the extraction algerian. Through the experiment, we draw out the result.

  • PDF

The Study of the Optical Fiber Current Sensor Using Faraday Effect (Faraday 효과를 이용한 광섬유 전류센서에 관한 연구)

  • 이정수;송시준;전재일;박원주;이광식;김정배;송원표
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.229-232
    • /
    • 2002
  • In this paper, we described the laboratory layout of the optical CT in connection with the measurement of large current for the GIS. The aim of this study is the development and application of optical CT based on Faraday effect. It was used He-Ne laser for light source (633nm) and was used PIN-Photodiode for light receiver. The laser source passes through optical fiber in single mode. We used the polarizer to polarize the light source and the beam splitter to divide the output light, and the optical fiber is connected for the measuring the angle polarized in the magnetic field.

  • PDF

The study of the cell charger using ZVS method (ZVS 방식을 이용한 셀 충전기의 연구)

  • 이종규;류희삼
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.277-279
    • /
    • 2002
  • This paper is an experimental research of the design of a cell battery charger using switching methods. The developed charger in this paper can do both the equalizing current charge and floating charge. Also, it is easily transferable. Power MOS FET was used for the full bridge converter of the charger, and ZVS was applied for the switching method of the converter. Also, Customized IC was used for the control circuit in order to simplify ZVS mode. The setting current and floating current used for the charger were designed by using OP AMP. Based on the process provided by the current research, a sample converter with the power rating of 5KVA was developed and is field-testing to improve its validity and stability.

  • PDF

A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter (전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한연구)

  • 장수진;류동균;서민성;김준호;원충연;배기훈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.151-156
    • /
    • 2002
  • The output voltage of Synchronous Generator is regulated constantly by field current control in excitation system. A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the constant output voltage under normal operating conditions about various levels. High frequency PWM converter (Current Mode Control Buck converter) type excitation system for synchronous generator is able to sustain output voltage level properly when the fault condition happened. This paper deals with the design and evaluation of the excitation system controller for a synchronous generator to improve the steady state and transient stability. The simulation and experimental results show that the proposed excitation system is improve the respons time by the AVR(automatic voltage regulator) of 50kW synchronous generator that is applied the current mode control excitation system.

  • PDF

An online Calibration Algorithm using binary spreading code for the CDMA-based Adaptive Antenna Array

  • Lee, Chong-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.32-39
    • /
    • 2006
  • In this paper, an iterative subspace-based calibration algorithm for a CDMA-based antenna array in the presence of unknown gain and phase error is presented. The algorithm does not depend on the array geometry and does not require a prior knowledge of the Directions Of Arrival (DOA) of the signals. The method requires the code sequence of a reference user only. The proposed algorithm is based on the subspace method and root finding approach, and it provides estimates of the calibration vector, the DOA and the channel impulse response, by using the code sequence of a reference user. The performance of the proposed algorithm was investigated by means of computer simulations and was verified using field data measured through a custom-built W-CDMA test-bed. The data show that experimental results match well with the theoretical calibration algorithm. Also, teh study propose an efficient algorithm using the simulated annealing technique. This algorithm overcomes the requirement of initial guessing in the subspace-based approach.

Analysis of the Thickness Effect for Hysteresis Ring of Hysteresis Motor with Vector Hysteresis Model

  • Hong, Sun-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.84-89
    • /
    • 2006
  • This paper presents the thickness effect of hysteresis ring of hysteresis motor using finite element method combined with a vector hysteresis model. From the magnitude and direction of the magnetic field intensity, the magnetization of each ring element is calculated by a vector hysteresis model. The developed torque can be obtained with the vector sum of individual torque of each element on the hysteresis ring. From these calculations, it can be found that the motor torque is not in proportion to the thickness of the ring. As a result, there exists a proper point of thickness and that can be determined using the proposed methoㅇ in this paper.

Fabrication and Characterization of Gate Insulator Thin Films prepared by Plasma Polymerization (플라즈마 중합법에 의한 게이트 절연박막의 제작 및 특성)

  • Son, Young-Do;Hwang, Myung-Whan;Lim, Jae-Sung;Shin, Paik-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.48-53
    • /
    • 2011
  • Polymer thin films were prepared by capacitively coupled plasma polymerization process for application of gate insulator. The polymer thin films revealed to form polymer layers with original properties of the monomer. Among the plasma polymer thin films, the styrene polymer having large number of phenyl sites revealed higher dielectric constant of k=3.7 than that of conventional polymer. The plasma polymerized styrene thin film revealed no hysteresis characteristics and low leakage current density of $1{\times}10^{-8}[Acm^{-2}]$ at field strength of $1[MVcm^{-1}]$, which measured by I-V and C-V measurements using MIM and MIS devices.

Case Studies for Potential Distribution due to Power Source by Environmental Condition (전원설비에 의한 공간조건별 전위분포 사례 연구)

  • Jung, Jin-Soo;Jung, Jong-Wook;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.50-58
    • /
    • 2011
  • In this paper, potential distribution analysis through the six kinds of case studies examined in the environmental conditions change within a limited space, by the power supply system installed. To interpret the potential distribution using electromagnetic field analysis program and the parameters were state of the ground, the outer wall of the configuration state and the presence of human potential distribution was simulated. Potential distribution analysis, the size of nominal voltage, depending on the impedance of human body to be determined on the impact of surprise decision, but if equipped with appropriate protective equipment can be protected from lightning have been confirmed.

Characteristics Analysis for Reactor Starting Method of 3-Phase Induction Motor Considering Saturation (포화성분을 고려한 3상 유도전동기 리액터 기동 특성 분석)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.65-70
    • /
    • 2012
  • Induction motor is the most widely used to obtain the driving force in the industrial site. Induction motor generates a high current at startup. Most of starting currents are often more than five times of rated current. This high starting current can cause problems such as the voltage drop in the system. In order to solve these problems, if the motor capacity is large, generally we use reactor starting method rather than direct on line starting method. When a high startup current passes through reactor, reactor can serve as a nonlinear elements. In this study, we analyzed that the current, torque and power of the induction motor are different from the change of linear and nonlinear components of the reactor magnetic field.

Analysis Technique of Risk Voltage around Grounding Electrode by New Touch and Step Voltage Measurement Methods (새로운 접촉 및 보폭전압 측정법에 의한 접지전극 주위의 위험전압 분석기법)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.81-86
    • /
    • 2012
  • This paper describes the analysis technique of risk voltage around grounding electrode by new touch and step voltage measurement methods. We have analyzed three techniques for risk voltage measurement, such as footprint-electrode method, test-probe method, and simulated-personnel method. We have selected test-probe method considering applicability of site. In order to reduce error related to the location of the auxiliary electrode, we propose a new approach to perform risk voltage measurement with minimum errors and short auxiliary electrode distances. Field tests were carried out at a grounding grid. It can be concluded that the proposed method will be satisfactory for risk voltage measurement.