• Title/Summary/Keyword: Field Installation

Search Result 1,198, Processing Time 0.021 seconds

Study on the dataset conformance testing IEC 61850 based IED (IEC 61850 IED대상 데이터세트 적합성 시험에 관한 연구)

  • Lee, N.H.;Jang, B.T.;Kim, J.H.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.371-374
    • /
    • 2008
  • KEPRI has carried out IEC61850 communication conformance test about the IED trial products. This paper describes dataset conformance testing, one of the IEC 61850-10 conformance test items, and test procedures on IED. KEPRI plans to construct the testing field of IEC 61850 based substation automation system with domestic IEDs confirmed their IEC 61850 communication service including dataset.

  • PDF

Charge-discharge properties by the superconducting energy transfer system (초전도에너지 전송시스템에 따른 충방전 특성)

  • Choi, Hyo-Sang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.363-365
    • /
    • 2005
  • It describes a design analysis and test results of an energy transfer system which consists of two 0.5 MJ superconducting coil and three Inverter-Converter Bridges(hereinafter called ICB). A point of design is to satisfy the required stored energy capacity rather than magnetic field density with minimum energy transfer time using the calculation results of state-space averaging methods instead of Fourier series. It is proven that the considered methods are effectively through system experiments.

  • PDF

Electronic field distribution with Switch contact configuration (개폐기 접점 형상에 의한 전계 분포)

  • Cho, Kook-Hee;Cho, Moon-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.301-304
    • /
    • 2005
  • 본 논문은 개폐기의 접점 형상에 따른 전계 분포 특성을 2차계 전자계 해석 program인 Flux-2D를 통해 살펴보았다. 2개의 모델을 선정하여 전극간 이격거리를 115[mm], 120[mm], 125[mm]로 변화를 주었을 때 최고 전계 강도의 변화를 살펴보았다. 1000[V] 인가시 최고 전계 강도는 (a)모델에서 115[mm]일 때 61.84[V/m], (b)모델에서 115[mm]일 때 66.90[V/m]로 나타났다.

  • PDF

Characteristics of double sided excitation LDM with multi-separated winding (분할 다권선형 LDM의 특성 해석)

  • 안홍기;김학련;신명호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.337-342
    • /
    • 2003
  • In this paper, in order to analyzing the thrust force of LDM, it was divided by the vertical force(Fx)and the horizontal force(Fy). The magnet and winding width was determined by analyzing the magnetic flux distribution throughout the airgap of LDM. Using finite-element analysis(FEA), which is the magnetic field analysis, and Proved the validity of design process, also the characteristics of LDM according to the variation of the design parameters of LDM was almost in accord with th experiment results.

  • PDF

The Field Situation Analysis of Street Lamp Which is Established in The Urban (도심에 설치된 가로등설비의 현장실태 분석)

  • 한운기;한기붕;길형준;최충석
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.117-122
    • /
    • 2003
  • Street light facilities, which are easily accessible, can be in danger of electric shock when water percolates the facilities especially in summer. In case deteriorated facilities are not checked regularly, they can cause accidents such as electric shock. We should consider regional characteristics to prevent this kind of accidents. In this paper, we analyzed the problems according to the facilities through the research on the actual conditions. We also analyzed the facilities by region and the standards by the conditions.

  • PDF

A spectrum sensing technique for green medical environments (친 의료 환경을 위한 스펙트럼 인지기술)

  • Kim, Seung-Hwan;Jeon, Tae-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.281-284
    • /
    • 2009
  • In this paper, we review the effects of RF interference of medical equipment or other electric equipment which can emit radio frequency in the general hospitals environments which are in many cases being under the influence of various electromagnetic field. Using spectrum analysis method we found some devices could effect on the frequency of telemetry system. We also investigate the relationship between intensity of the signal and distance for the selected equipment used in hospitals.

  • PDF

The Characteristics of Surface Flashover on the Semiconductor in High Electric-Field (고전계 하에서 반도체 연면방전 특성)

  • 이세훈;이충식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.35-43
    • /
    • 2002
  • In the last decade, considerable efforts have been made to make a new class of solid state high power, high speed electronic device, namely, the Photo-Conductive Power Switch(PCPS), and to characterize the high-field performance of PCPS under high power, high voltage conditions. But the problem of surface flashover phenomena persist, preventing the realization of reliable and efficient high-speed, high voltage switching devices. It is essential to have a clear understanding on the physical processes behind the surface flashover problem to develop new technologies and device architectures so as to fabricate PCPS that are capable of high-field high-voltage. Also, it is imperative to identify new materials that could satisfy the requirements for high-field, high-power devices. Since surface flashover, surface breakdown phenomena is observed for all the devices that foiled at the applied field much lower than semiconductor bulk breakdown field, surface passivation is considered one of the important practical methods to improve the high field performance of the devices. Therefore, this paper was studied the main properties and mechanism of the semiconductor surface flashover before and after passivation under high electric-field.

Calculation of Induced Current in the Human Body by Magnetic Field in the 100kHz~10MHz Resonant WPT Frequency Range and Analysis of EMF Guideline (공진형 무선전력전송 대역의 100kHz~10MHz 자기장에 의한 인체유도전류계산과 전자기장 인체보호기준 분석)

  • Shin, Hansu;Song, Hye-Jin;Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.110-119
    • /
    • 2013
  • As the technologies such as middle-range resonant WPT (wireless power transfer) advance that utilizes medium and low-frequency magnetic field, the importance of safety of such magnetic field is growing. The research on the effect of electromagnetic field on the human body has been mainly done on the GHz range of mobile phones, or 50~60Hz range of electric power systems. However, there has been relatively few works on the 100kHz~10MHz range used in the resonant wireless power transfer. Since there is a difference in the limiting value of magnetic field between widely used ICNIRP EMF guideline and IEEE C95.1 standard, there can be possible confusion when establishing EMF (Electromagnetic Field) standard on the wireless power transfer device in the future. In this paper, the induced current in the human body, which is the basic restriction of the EMF guideline, is calculated using Quasi-static FDTD method when 3D high-resolution human model is exposed to the 100kHz~10MHz magnetic field. Using this result, the feasibility of the magnetic field reference level in the ICNIRP guideline is analyzed.

Human Reliability Assessment for a Installation Task of Temporary Power Cables in Construction Fields (건설현장 임시전력 배선의 가설직무에 대한 인간신뢰성 평가)

  • Kim Doo-Hyun;Lee Jong-Ho;Kim Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.61-66
    • /
    • 2005
  • This paper presents an human reliability assessment(HRA) for a installation task of the temporary power cable in construction fields. HRA is evolved to ensure that the workers could reliably perform critical tasks such as a process of the temporary power cable. Human errors are extremely commonplace, with almost everyone committing at least some errors every day. The considerable parts of electric shock accidents in the construction field are caused by a series of human errors. Therefore it is required to analyze the human errors contained in the task causing electric shock event, the event tree analysis(ETA) is adopted in this paper, and particularly human reliability was estimated for a installation task of the temporary power cables. It was assumed that the error probabilities of the human actions may be obtained using the technique for human error rate prediction(THERP). The results show that the predominant task on reliability in the cable installation tasks is check-out tasks and the probability causing electric shock by human errors was calculated as $1.0\times10^{-9}$.

The effect of group pile installation (무리말뚝 시공의 영향)

  • Lee, Myung-Whan;Hong, Hun-Sung;Kim, Sung-Hoi;Jun, Young-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1303-1311
    • /
    • 2006
  • Most of the piles are designed as group piles. In certain geotechnical environments, the installation of group piles causes heaving of the already installed piles. The unfavorable effects of pile heaving on pile bearing capacity have been well known to field engineers. However not many engineers pay enough attention to this subject. According to our recent researches, not only the bearing capacity but also the pile material could be seriously damaged due to the installation of nearby piles, especially with the cases of precast concrete piles. When the pull-out force due to installation of neighboring piles acting on the already installed precast concrete pile exceeds the shaft friction, pile heaving occurs. At the same time, if the pull-out force exceeds the allowable tensile strength of the precast concrete pile, tensile failure is inevitable, which is critical for the pile integrity. In other cases the pile material was not damaged but serious relaxation occurred as the results of pile heaving. In this paper, the pull-out mechanism due to the installation of group piles is explained.

  • PDF