• Title/Summary/Keyword: Fault Location Algorithm

Search Result 162, Processing Time 0.031 seconds

A Study on Operation Method of Protection Device for LVDC Distribution Feeder in Light Rail System (경전철용 LVDC 배전계통의 보호기기 운용 방안에 관한 연구)

  • Kang, Min-Kwan;Choi, Sung Sik;Lee, Hu-Dong;Kim, Gi-Yung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.25-34
    • /
    • 2019
  • Recently, when a fault occurs at a long-distance point in a LVDC (low voltage direct current) distribution feeder in a light rail system, the magnitude of the current can decrease to less than that of the load current of a light rail system. Therefore, proper protection coordination method to distinguish a fault current from a load current is required. To overcome these problems, this paper proposes an optimal algorithm of protection devices for a LVDC distribution feeder in a light rail system. In other words, based on the characteristics of the fault current for ground resistance and fault location, this paper proposes an optimal operation algorithm of a selective relay to properly identify the fault current compared to the load current in a light rail system. In addition, this paper modelled the distribution system including AC/DC converter using a PSCAD/EMTDC S/W and from the simulation results for a real light rail system, the proposed algorithm was found to be a useful and practical tool to correctly identify the fault current and load current.

Detection and Estimation of a Faults on Coaxial Cable with TFDR Algorithm (Time Frequency Domain Reflectometry 기법을 이용한 Coaxial Cable에서의 결함 감지 및 추정)

  • Song, Eun-Seok;Shin, Yong-June;Choe, Tok-Son;Yook, Jong-Gwan;Park, Jin-Bae;Powers, Edward J.
    • Journal of Advanced Navigation Technology
    • /
    • v.7 no.1
    • /
    • pp.38-50
    • /
    • 2003
  • In this paper, a new high resolution reflectometry scheme, time-frequency domain reflectometry (TFDR), is proposed to detect and locate fault in wiring. Traditional reflectometry methods have been achieved in either the time domain or frequency domain only. However, time-frequency domain reflectometry utilizes time and frequency information of a transient signal to detect and locate the fault. The time-frequency domain reflectometry approach described in this paper is characterized by time-frequency reference signal design and post-processing of the reference and reflected signals to detect and locate the fault. Design of the reference signal in time-frequency domain reflectometry is based on the determination of the frequency bandwidth of the physical properties of cable under test. The detection and estimation of the fault on the time-frequency domain reflectometry relies on the time-frequency domain reflectometry is compared with commercial time domain reflectomtery (TDR) instrument. In these experiments provided in this paper, TFDR locates the fault with smaller error than TDR. Knowledge of time and frequency localized information for the reference and reflected signal gained via time-frequency analysis, allows one to detect the fault and estimate the location accurately.

  • PDF

Bearing faults localization of a moving vehicle by using a moving frame acoustic holography (이동 프레임 음향 홀로그래피를 이용한 주행 중인 차량의 베어링 결함 위치 추정)

  • Jeon, Jong-Hoon;Park, Choon-Su;Kim, Yang-Hann;Koh, Hyo-In;You, Won-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.681-688
    • /
    • 2009
  • This paper deals with a bearing faults localization technique based on holographic approach by visualizing sound radiated from the faults. The main idea stems from the phenomenon that bearing faults in a moving vehicle generate impulsive sound. To visualize fault signal from the moving vehicle, we can use the moving frame acoustic holography [H.-S. Kwon and Y.-H. Kim, "Moving frame technique for planar acoustic holography," J. Acoust. Soc. Am. 103(4), 1734-1741, 1998]. However, it is not easy to localize faults only by applying the method. This is because the microphone array measures noise (for example, noise from other parts of the vehicle and the wind noise) as well as the fault signal while the vehicle passes by the array. To reduce the effect of noise, we propose two ideas which utilize the characteristics of fault signal. The first one is to average holograms for several frequencies to reduce the random noise. The second one is to apply the partial field decomposition algorithm [K.-U. Nam, Y.-H. Kim, "A partial field decomposition algorithm and its examples for near-field acoustic holography," J. of Acoust. Soc. Am. 116(1), 172-185, 2004] to the moving source, which can separate the fault signal and noise. Basic theory of those methods is introduced and how they can be applied to localize bearing faults is demonstrated. Experimental results via a miniature vehicle showed how well the proposed method finds out the location of source in practice.

  • PDF

K-connected, (K+1)-covered Fault-tolerant Topology Control Protocol for Wireless Sensor Network (무선 센서 망을 위한 K-연결 (K+1)-감지도 고장 감내 위상 제어 프로토콜)

  • Park, Jae-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11B
    • /
    • pp.1133-1141
    • /
    • 2009
  • In this paper, we present a distributed fault-tolerant topology control protocol that configure a wireless sensor network to achieve k-connectivity and (k+1)-coverage. One fundamental issue in sensor networks is to maintain both sensing coverage and network connectivity in order to support different applications and environments, while some least active nodes are on duty. Topology control algorithms have been proposed to maintain network connectivity while improving energy efficiency and increasing network capacity. However, by reducing the number of links in the network, topology control algorithms actually decrease the degree of routing redundancy. Although the protocols for resolving such a problem while maintaining sensing coverage were proposed, they requires accurate location information to check the coverage, and most of active sensors in the constructed topology maintain 2k-connectivity when they keep k-coverage. We propose the fault-tolerant topology control protocol that is based on the theorem that k-connectivity implies (k+1)-coverage when the sensing range is at two times the transmission range. The proposed distributed algorithm does not need accurate location information, the complexity is O(1). We demonstrate the capability of the proposed protocol to provide guaranteed connectivity and coverage, through both geometric analysis and extensive simulation.

Particle Based Discrete Element Modeling of Hydraulic Stimulation of Geothermal Reservoirs, Induced Seismicity and Fault Zone Deformation (수리자극에 의한 지열저류층에서의 유도지진과 단층대의 변형에 관한 입자기반 개별요소법 모델링 연구)

  • Yoon, Jeoung Seok;Hakimhashemi, Amir;Zang, Arno;Zimmermann, Gunter
    • Tunnel and Underground Space
    • /
    • v.23 no.6
    • /
    • pp.493-505
    • /
    • 2013
  • This numerical study investigates seismicity and fault slip induced by fluid injection in deep geothermal reservoir with pre-existing fractures and fault. Particle Flow Code 2D is used with additionally implemented hydro-mechanical coupled fluid flow algorithm and acoustic emission moment tensor inversion algorithm. The output of the model includes spatio-temporal evolution of induced seismicity (hypocenter locations and magnitudes) and fault deformation (failure and slip) in relation to fluid pressure distribution. The model is applied to a case of fluid injection with constant rates changing in three steps using different fluid characters, i.e. the viscosity, and different injection locations. In fractured reservoir, spatio-temporal distribution of the induced seismicity differs significantly depending on the viscosity of the fracturing fluid. In a fractured reservoir, injection of low viscosity fluid results in larger volume of induced seismicity cloud as the fluid can migrate easily to the reservoir and cause large number and magnitude of induced seismicity in the post-shut-in period. In a faulted reservoir, fault deformation (co-seismic failure and aseismic slip) can occur by a small perturbation of fracturing fluid (<0.1 MPa) can be induced when the injection location is set close to the fault. The presented numerical model technique can practically be used in geothermal industry to predict the induced seismicity pattern and magnitude distribution resulting from hydraulic stimulation of geothermal reservoirs prior to actual injection operation.

Investigation of the Preventive Diagnostic Criteria for Power Transformer (전력용 변압기 예방진단 기준치 검토)

  • Kweon, D.J.;Koo, K.S.;Kang, Y.W.;Woo, J.W.;Kwak, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.592-596
    • /
    • 2005
  • The preventive diagnostic system prevents transformers from power failure by giving alarm and observing transformers in service. And it helps to establish the plan for optimum maintenance of transformer as well as to find location or cause of fault using accumulated data. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Techniques for component sensors of preventive diagnostic system were settled but diagnostic algorithm, diagnostic criteria and practical use of accumulated data are not yet established. This paper, to build up the base of preventive diagnostic algorithm for the power transformer, investigated the preventive diagnostic criteria for power transformer.

  • PDF

Update Propagation Protocol Using Tree of Replicated Data Items in Partially Replicated Databases

  • Bae, Misook;Hwang, Buhyun
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1859-1862
    • /
    • 2002
  • The replication of data is used to increase its availability, improve the performance of a system, and advance the fault-tolerance of a system. In this paper, it is required for the information about the location of a primary site of the replicas of each data item. The replicas of each data item are hierarchically organized to a tree based on the fact that the root is the primary replica in partially replicated databases. It eliminates useless propagation since the propagation can be done to only sites having replicas following the hierarchy of data. And our algorithm schedules transactions so that the execution order of updates at each primary site is identical at all sites by using timestamp. Using our algorithm, the consistent data are supplied and the performance of read-only transactions can be improved by using tree structure of replicas of each data item.

  • PDF

Establishment of Diagnostic Criteria in the Preventive Diagnostic System for the Power Transformer (전력용 변압기 예방진단새스템의 진단기준치 실정)

  • Kweon Dong-Jin;Koo Kyo-Sun;Kwak Joo-Sik;Woo Jung-Wook;Kang Yeon-Wook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.449-456
    • /
    • 2005
  • The preventive diagnostic technique prevents transformers from power failure through giving alarm and observing transformers in service. And it helps to establish the plan for optimum maintenance of the transformer as well as to find location or cause of fault using accumulated data. Data detection and experience of the preventive diagnostic system need to establish the preventive diagnostic algorithm regarding interrelationship between detected data and deterioration of equipment. Therefore in-depth analysis about the preventive diagnosis system is required. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Techniques for component sensors of the preventive diagnosis system were settled but diagnosis algorithm, diagnostic criteria and practical use of accumulated data are not yet established. This paper, to build up the base of preventive diagnostic algorithm for the Power transformer. investigated the preventive diagnostic criteria for the power transformer.

A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power Trajectory in Complex Plane (복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 복소전력의 궤적변화)

  • Kwon O-Sang;Kim Chul-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.7
    • /
    • pp.345-351
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load, the oscillation can be severe and even increase largely and finally the out-of-step condition may un. During the power swing and out-of-step conditions, the apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.

Built-In Self Repair for Embedded NAND-Type Flash Memory (임베디드 NAND-형 플래시 메모리를 위한 Built-In Self Repair)

  • Kim, Tae Hwan;Chang, Hoon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.5
    • /
    • pp.129-140
    • /
    • 2014
  • BIST(Built-in self test) is to detect various faults of the existing memory and BIRA(Built-in redundancy analysis) is to repair detected faults by allotting spare. Also, BISR(Built-in self repair) which integrates BIST with BIRA, can enhance the whole memory's yield. However, the previous methods were suggested for RAM and are difficult to diagnose disturbance that is NAND-type flash memory's intrinsic fault when used for the NAND-type flash memory with different characteristics from RAM's memory structure. Therefore, this paper suggests a BISD(Built-in self diagnosis) to detect disturbance occurring in the NAND-type flash memory and to diagnose the location of fault, and BISR to repair faulty blocks.