• 제목/요약/키워드: Fast scan mode

검색결과 11건 처리시간 0.039초

New Protocol at Fast Scan Mode for Sea-surface Small Target Detection

  • Cha, Sangbin;Park, Sanghong;Jung, Jooho;Choi, Inoh
    • 대한임베디드공학회논문지
    • /
    • 제17권2호
    • /
    • pp.101-107
    • /
    • 2022
  • In this article, we propose a new protocol at fast scan mode for a sea-surface small target detection. The conventional fast scan mode is composed of coherent intrascan integration to suppress sea clutter and non-coherent interscan integration to exclude sea spikes. The proposed method realizes the coherent interscan integration by the new Fourier relationship between carrier-frequency and initial-radial-range, which can be analytically derived by using multiple carrier frequencies at fast scan mode, leading to improved detection performance, compared to the conventional non-coherent methods. In simulations, our proposed method is verified.

Test of a Multilayer Dose-Verification Gaseous Detector with Raster-Scan-Mode Proton Beams

  • Lee, Kyong Sei;Ahn, Sung Hwan;Han, Youngyih;Hong, Byungsik;Kim, Sang Yeol;Park, Sung Keun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권5호
    • /
    • pp.297-304
    • /
    • 2015
  • A multilayer gaseous detector has been developed for fast dose-verification measurements of raster-scan-mode therapeutic beams in particle therapy. The detector, which was constructed with eight thin parallel-plate ionization chambers (PPICs) and polymethyl methacrylate (PMMA) absorber plates, is closely tissue-equivalent in a beam's eye view. The gas-electron signals, collected on the strips and pad arrays of each PPIC, were amplified and processed with a continuous charge.integration mode. The detector was tested with 190-MeV raster-scan-mode beams that were provided by the Proton Therapy Facility at Samsung Medical Center, Seoul, South Korea. The detector responses of the PPICs for a 190-MeV raster-scan-mode proton beam agreed well with the dose data, measured using a 2D ionization chamber array (Octavius model, PTW). Furthermore, in this study it was confirmed that the detector simultaneously tracked the doses induced at the PPICs by the fast-oscillating beam, with a scanning speed of 2 m s-1. Thus, it is anticipated that the present detector, composed of thin PPICs and operating in charge.integration mode, will allow medical scientists to perform reliable fast dose-verification measurements for typical dynamic mode therapeutic beams.

Application of Fast Atom Bombardment Collision-induced Dissociation Tandem Mass Spectrometry for Structural identification of Glycerolipids Isolated From Marine Sponge

  • Lee, Sun-Young;Hong, Joo-Yeon;Jung, Jee-H.;Hong, Jong-Ki
    • Mass Spectrometry Letters
    • /
    • 제2권1호
    • /
    • pp.8-11
    • /
    • 2011
  • Two types of glycerolipids [monoacylglycerols (MAG) and cyclitols] were isolated by reversed phase high-performance liquid chromatography from the methanol extracts of a marine sponge, and analyzed by fast atom bombardment mass spectrometry (FAB-MS) in positive-ion mode. FAB mass spectra of these compounds yielded protonated molecules $[M + H]^+$ and abundant sodiated molecules $[M + Na]^+$ from a mixture of 3-nitrobenzyl alcohol and NaI. The structures of these compounds were elucidated by FAB-collisional-induced dissociation (CID)-tandem mass spectrometry. We carried out collision-indused dissociation (CID) of these lipids in B/E-linked scan mode. The CID B/E-linked scan of $[M + H]^+$ and $[M + Na]^+$ precursor ions resulted in the formation of numerous characteristic product ions through a series of dissociative processes. The product ions formed by charge-remote fragmentation (CRF) provided important information for the identification of the acyl chain structure substituted at the glycerol backbone. Some of the product the ions were diagnostic for the presence of a glycerol backbone or acyl chain structure.

난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study (Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition)

  • 이성재;신충훈;최소영;이동형;유순미;송흥권;윤인하
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.73-82
    • /
    • 2022
  • 목 적: 본 연구는 난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 HalcyonTM Fast kV CBCT를 사용하였을 때 난소에 미치는 흡수선량과 영상의 품질을 분석하여 유용성을 평가하고자 한다. 대상 및 방법: 인체모형 팬텀(Alderson Rando Phantom, USA)의 전산화단층촬영 영상에 측정에 필요한 자궁경부와 난소의 윤곽묘사(contouring)를 하였고, 해당 장기 단면에 광자극발광선량계(Optically Stimulated Luminescence Dosimeter, OSLD, InLight system, Landauer, USA)를 각각 3개씩 부착하였다. TruebeamTM의 Pelvis mode(이하 TP)와 HalcyonTM의 Pelvis mode(이하 HP) 그리고 HalcyonTM의 Pelvis Fast mode(이하 HPF)에서 자궁경부와 난소에 들어가는 흡수선량을 측정하기 위해 촬영 범위를 17.5 cm와 12.5 cm로 촬영 범위를 축소한 영상을 촬영하였다. 총 10회의 누적선량을 합산하였고, 자궁경부암 치료 횟수인 23회의 값으로 치환하여 비교하였다. 또한 영상 장비 간의 CBCT 영상 품질을 비교하기 위해 Catphan 504 팬텀(The Phantom Laboratory, USA)을 이용하여 균일도(Uniformity), 저 대조도 가시(Low contrast visibility, LCV), 공간분해능(Spatial resolution), 기하학적 왜곡(Geometric Distortion)을 비교 분석하였다. 각각 3회 반복 측정하여 Doselab (Versions: 6.8, Mobius Medical Systems) 프로그램으로 분석 후 평균값을 구하였다. 결 과: CBCT에 의한 흡수선량을 OSLD로 측정한 결과 동일한 조건일 시 TP와 HP는 유의미한 결과를 얻지 못하였다. 가장 큰 감소 값을 보인 모드는 TP 대비 HPF였다. HPF는 17.5 cm의 촬영 범위에서 흡수선량이 TP보다 자궁경부가 약 39.82%, 난소에서 약 19.8% 감소 하였고, 12.5 cm 으로 촬영 범위를 축소할 경우 자궁경부는 34.2%, 난소 50.5%로 감소 시킬 수 있었다. 또한 위 실험에서 사용된 영상의 품질을 평가한 결과 Geometric Distortion 1mm 이내(SBRT 기준), Uniformity HU, LCV 2.0% 이내 Spatial Resolution 3 lp/mm 이상으로 장비사의 기준치를 준수하였다. 결 론: 본 실혐 결과에 따라 난소전위술을 시행한 가임기 여성의 방사선치료 시 CBCT로 인한 피폭선량을 낮추기 위해서는 TruebeamTM 보다 다양한 조건을 선택 할 수 있는 HalcyonTM이 유용할 것으로 평가 되며, 특히 낮은 mAs로도 영상의 품질을 유지하는 HalcyonTM의 Fast kV CBCT를 권장한다. 다만 다른 치료 장비에서도 난소전위를 시행한 환자는 촬영 범위를 조정하는 것으로 저선량에 대한 추가적인 피폭 감소시킬 수 있을 것으로 사료된다.

전자기 초음파를 이용한 CFRP 복합적층판의 적층배향 특성평가에 관한 연구 (A Study on Characterization for Stacking Fault Evaluation of CFRP Composite Laminates Using an EMAT Ultrasonics)

  • 임광희;나승우;김지훈;이창노;;양인영
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.83-92
    • /
    • 2005
  • An electromagnetic acoustic transducer (EMAT) is a unique probe that does not require a couplant or gel and also can usually generate or detect an ultrasonic wave into specimens across a small gap. It, therefore can be applied in a noncontact mode with a high degree of reproducibility. Especially stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates. It is very important to evaluate the layup errors in prepreg laminates. A nondestructive technique can therefore serve as a useful measurement for detecting layup errors. This shear wave for detecting the presence of the errors is very sensitive. A decomposition model has been used in the interpretation and prediction of test results. Test results have been com pared with model data. It is found that the high probability shows between tests and the model utilized in characterizing cured layups of the laminates. Also a C-scan method was used for detecting layup of the laminates because of extracting fiber orientation information from the ultrasonic reflection caused by structural imperfections in the laminates. Therefore, it was found that interface C-scan images show the fiber orientation information by using two-dimensional fast Fourier transform (2-D FFT).

1.6 m 신태양망원경용 고속영상태양분광기 개발 (DEVELOPMENT OF THE FAST IMAGING SOLAR SPECTROGRAPH FOR 1.6 m NEW SOLAR TELESCOPE)

  • 나자경;채종철;박영득;박형민;장비호;안광수;양희수;조경석;김연한;김광동
    • 천문학논총
    • /
    • 제26권1호
    • /
    • pp.45-54
    • /
    • 2011
  • KASI and Seoul National University developed the Fast Imaging Solar Spectrograph (FISS) as one of major scientific instruments for the 1.6 m New Solar Telescope (NST) and installed it in the Coude room of the NST at Big Bear Solar Observatory (BBSO) in May, 2010. The major objective of the FISS is to study the fine-scale structures and dynamics of plasma in the photosphere and chromosphere. To achieve it, the FISS is required to take data with a spectral resolution higher than $10^5$ at the spectrograph mode and a temporal resolution less than 10 seconds at the imaging mode. The FISS is a spectrograph using Echelle grating and has characteristics that can observe dual bands (H${\alpha}$ and CaII 8542) simultaneously and perform fast imaging using fast raster scan and two fast CCD cameras. In this paper, we introduce briefly the whole process of FISS development from the requirement analysis to the first observations.

High Speed SD-OCT System Using GPU Accelerated Mode for in vivo Human Eye Imaging

  • Cho, Nam Hyun;Jung, Unsang;Kim, Suhwan;Jung, Woonggyu;Oh, Junghwan;Kang, Hyun Wook;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.68-72
    • /
    • 2013
  • We developed an SD-OCT (Spectral Domain-Optical Coherence Tomography) system which uses a GPU (Graphics Processing Unit) for processing. The image size from the SD-OCT system is $1024{\times}512$ and the speed is 110 frame/sec in real-time. K-domain linearization, FFT (Fast Fourier Transform), and log scaling were included in the GPU processing. The signal processing speed was about 62 ms using a CPU (Central Processing Unit) and 1.6 ms using a GPU, which is 39 times faster. We performed an in-vivo retinal scan, and reconstructed a 3D visualization based on C-scan images. As a result, there were minimal motion artifacts and we confirmed that tomograms of blood vessels, the optic nerve, and the optic disk are clearly identified. According to the results of this study, this SD-OCT can be applied to real-time 3D display technology, particularly auxiliary instruments for eye operations in ophthalmology.

Search for Very Fast Variability in AGN Radio Light Curves

  • 이태석;;손봉원;이상성;변도영;오정환
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.43.1-43.1
    • /
    • 2013
  • We present here the preliminary results of the fast variability of AGN radio light curves. The shortest time scale of minute in AGN light curves is needed to probe the AGN activity for a few reasons; First, to check if there is any kind of shortest time scale activity. Secondly, to find out what high frequency end of AGN spectra look like. For the last, to see the time delay at several wavelength bands and the change of the spectral index with time. The observation was conducted with three KVN(Korea VLBI Network) antennas with single dish cross scan mode. In order not to lose the target at any given time, whenever one station needs to observe the calibrator, the other station is on the target. Though the detailed data reduction is still going on, there might exist varying feature in the radio light curve. The more fine calibration will be done in near future and another good data set is ready for the reduction.

  • PDF

Fast Response Technique 2 Quadrant DC Motor Speed Control

  • W. Piyarat;V. Tipsuwanporn;W. Sawangsinkasikit;Lee, M. lajindarairerk;P. Thepsatorn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.244-247
    • /
    • 1999
  • This paper presents a methodology of the technique for controlling DC motor drive by implementation of 2-quadrant operating mode which can ensure the torque controlling and speed with response time less than 2 seconds at all loading conditions. By implementation of BRM technique, energy is fed with definite values of BRM 256 bits, with different patterns of high accuracy, and fixing scan time at 0.667 ms, the ripple is less than 1%, thus high efficiency can be achieved, from the consequence of the accuracy of energy feeding at low current. The stability of the whole system can be determined from circle criterion by root locus method . The instant reverse direction of rotation can be done by decreasing the energy to the lowest level while motor is running with no load and variable load at the speed about 100-120 rpm and 50-60 rpm.

  • PDF