• Title/Summary/Keyword: Facility safety design

Search Result 508, Processing Time 0.026 seconds

An Experiment of Natural Circulated Air Flow and Heat Transfer in the Passive Containment Cooling System (격납용기 피동냉각계통내 자연순환 공기유량 및 열전달 실험연구)

  • Ryu, S.H.;Oh, S.M.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.516-525
    • /
    • 1994
  • Since the TMI and Chernobyl accidents, many passive safety features are suggested in advanced reactors in order to enhance the safety in future nuclear power plants. In order to verify the effectiveness and provide the data for detailed design of passive cooling system, in the present work, the effects of air inlet position and external condition on the natural circulated air flow rate and the natural and forced convective heat transfer coefficient have been investigated for the one-side heated closed path such as the passive containment cooling system of the Westinghouse's AP-600. A series of experiments have been peformed with the 1/26th scaled segment type test facility of the AP-600 passive containment. Under natural and forced convection, the air velocities and temperatures are measured at several points of the air flow path. The experimental result are compared with a simple one-dimensional model and it shows a good agreement.

  • PDF

Study of hydrodynamics and iodine removal by self-priming venturi scrubber

  • Jawaria Ahad;Talha Rizwan ;Amjad Farooq ;Khalid Waheed ;Masroor Ahmad ;Kamran Rasheed Qureshi ;Waseem Siddique ;Naseem Irfan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.169-179
    • /
    • 2023
  • Filtered containment system is a passive safety system that controls the over-pressurization of containment in case of a design-based accidents by venting high pressure gaseous mixture, consisting of air, steam and radioactive particulate and gases like iodine, via a scrubbing system. An indigenous lab scale facility was developed for research on iodine removal by venturi scrubber by simulating the accidental scenario. A mixture of 0.2 % sodium thiosulphate and 0.5 % sodium hydroxide, was used in scrubbing column. A modified mathematical model was presented for iodine removal in venturi scrubber. Improvement in model was made by addition of important parameters like jet penetration length, bubble rise velocity and gas holdup which were not considered previously. Experiments were performed by varying hydrodynamic parameters like liquid level height and gas flow rates to see their effect on removal efficiency of iodine. Gas holdup was also measured for various liquid level heights and gas flowrates. Removal efficiency increased with increase in liquid level height and gas flowrate up to an optimum point beyond that efficiency was decreased. Experimental results of removal efficiency were compared with the predicted results, and they were found to be in good agreement. Maximum removal efficiency of 99.8% was obtained.

A Study on the Analysis of Current Situation of Safety Inspections cost in Apartment houses (공동주택 안전점검대가 현황분석에 관한 연구)

  • Go, Seong-Seok;Song, Do-Heom;Yun, Yeong-Chae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.2
    • /
    • pp.62-70
    • /
    • 2014
  • An apartment house, a private facility, is a house built for many persons to live independently in a building. An apartment house is a building where life damage can happen most in case of a safety accident due to insufficient inspections. However, formal inspections are being realized due to awareness shortage of managing bodies about safety inspection and low-price order-receiving of diagnosing enterprises via the lowest bidding method. This is because it is judged that remarkable costs are inputted in repairs and reinforcement such as maintenance of a structure and that there is a large possibility of human damage in case of a safety accident in a structure. So, this paper aims to derive the points to improve in the current criterion to execute an efficient detailed inspection. As its method, the design price and execution price situation of 66 buildings inspected in detail for recent 3 years for the class 2 facilities in Gwangju Metropolitan City and Jeonranam-do are examined and analyzed. The state2 object buildings to inspect are selected through this. And this paper aims to present the points to improve through the analysis of current problems by evaluating the detailed inspection report and the detailed inspection execution price calculation criterion for the selected 10 apartment houses.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.

Seismic Performance Evaluation of the Li-Polymer Battery Rack System for Nuclear Power Plant (원자력발전소용 리튬폴리머 배터리 랙 시스템의 내진성능평가)

  • Kim, Si-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.13-19
    • /
    • 2019
  • After the Fukushima nuclear accident, a new power supply using a lithium polymer battery has been proposed the first time in the world as the safety of the emergency battery facility has been required. It is required to have the safety of the rack system in which the battery device is installed in order to apply the proposed technology to the field. Therefore, the purpose of this study is to evaluate the seismic performance of string and rack frame for lithium-polymer battery devices developed for the first time in the world to satisfy 72 hours capacity. (1) The natural frequency of the unit rack system was 9 Hz, and the natural frequency before and after the earthquake load did not change. This means that the connection between members is secured against the design earthquake load. (2) he vibration reduction effect by string design was about 20%. (3) As a result of the seismic performance test under OBE and SSE conditions, the rack frame system was confirmed to be safe. Therefore, the proposed rack system can be applied to the nuclear power plant because the rack system has been verified structural safety to the required seismic forces.

Analysis of Satisfaction on Alley Garden's Components through Urban Regeneration - Focused on Bisan 2·3-dong in Daegu Metropolitan City - (도시재생사업에 따른 골목정원 구성요소의 만족도 분석 - 대구광역시 비산 2·3동을 대상으로 -)

  • Jang, Cheol-Kyu;Hwang, Myeong-Lan;Shin, Jae-Yun;Jung, Sung-Gwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.137-148
    • /
    • 2017
  • This study analyzed the opinions of residents for desirable urban regeneration and suggested an improvement plan for alley environments. This study conducted a questionnaire survey of the residents living in Alley Garden of Bisan 2,3-dong, Daegu Metropolitan City. In the analysis of the importance and satisfaction of Alley Garden components, items related to a safe, cleanly environment such as 'Lighting facility installation', 'Sewage and waste disposal' and 'CCTV installation' had a high level of importance. It was also found that items improved by the Residential Environment Improvement Project and Alley Garden such as 'Lighting facility installation', 'Quantity of herbaceous flowers' and 'Kinds of herbaceous flowers' had a high level of satisfaction. The IPA results showed that items such as 'Empty house maintenance', 'Rest facilities such as benches and pergolas', 'Space for resident interaction' and 'Public parking lot' had a high level of importance, but had a low level of satisfaction, which suggests that they should be improved by priority. As a result of factor analysis, Alley Garden components were classified into four factors: 'Safety and cleanliness', 'Greenness', 'Exchange and convenience facility' and 'Aesthetics renewal'. Based on this classification, a regression analysis was conducted regarding the effects of the four factors on overall satisfaction. Results showed that all four factors had a significant influence on the overall satisfaction and that 'Aesthetics renewal' and 'Safety and cleanliness', respectively showing levels of significance at 0.274 and 0.235, were highly influential to overall satisfaction. Therefore, it was concluded that spaces for resident interaction and rest facilities should be preferentially installed to improve the environment of alleys. For the improvement of the overall satisfaction of alley environments, it was also concluded that residents should be encouraged to engage in activities such as sculpture installation and mural drawing, along with the introduction of safety bells and crime prevention environment design and the implementation of alley beautification projects.

A Study on the Ship Channel Design Method using Variable Bumper Area Model (I) (가변범퍼영역모델을 이용한 항로설계기법(I))

  • Jeong Dae-Deug;Lee Joong-Woo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.169-174
    • /
    • 2004
  • To design ship channel is one of important factors for planning and developing a port. In most case, the core factors for designing ship channel are the layout and width of dvnnel provided the net underkeel clearance is assessed as safety. In this study, Variable Bumper Area(VBA) model is applied to design and assess ship channel. This model reflects ship's principle dimension, ship domain theory, ship speed, conning officer's ship handling skill and experience and all external forces which cause leeway, set and drift and the change of ship maneuvering characteristics. Full Mission Ship Handling Simulator is used to analyze ship dynamic data according to conning officer's ship control, external forces, etc. This model uses Domain-index for assessing the efficiency and safety of the channel. The proposed model is applied to Ulsan new port plan which has a channel width of 1.5 times the length if the largest vessel, a radius if 5 times the length of the largest vessel in a curve of 57 degree centerline angle and SBM facility adjacent to the lateral edge if channel. The result of this study shows tint the width and radius of channel curve are suitable for the target ship but the difficulty of ship handling is caused by the large course change and SBM located in the vicinity if channel.

  • PDF

Focus Group Interview on Opinion about the Design and Management of Toothbrushing Facilities (양치시설 설계 및 운영에 대한 관련 실무자의 견해: 초점집단면접 연구)

  • Lee, Hyo-Jin;Paik, Dai-Il
    • Journal of dental hygiene science
    • /
    • v.16 no.2
    • /
    • pp.118-126
    • /
    • 2016
  • This study collected opinions about the design and management of toothbrushing facilities from schoolteachers and the people in charge of public centers, through a focus group interview (FGI), for the development of guidelines. Four moderators conducted eight FGIs of 32 subjects in charge of toothbrushing facilities across all the regions. The qualitative data was analyzed by constant comparative analysis. The findings indicated that more students utilized the facility and brushed their teeth after the installation of toothbrushing facilities. To enhance students' accessibility and safety, guidelines for design and management guidelinesfor toothbrushing facilities need to be developed; the location, sink height and depth, drain size, etc. should be comprehensively considered in the development of the guidelines. This study can help to improve students' satisfaction by enhancing the accessibility, safety, and functionality of toothbrushing facilities, and by providing fundamental data for toothbrushing facilities' development. Finally, this study can maximize the effects of management of toothbrushing facilities management on the improvement of students' oral health and behaviors.

Research on the Design of Drone System for Field Support Using AR Smart Glasses Technology (AR스마트안경 기술을 접목한 현장 지원용 드론(Drone)시스템 설계에 대한 연구)

  • Lee, Kyung-Hwan;Jeong, Jin-Kuk;Ryu, Gab-Sang
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.27-32
    • /
    • 2020
  • High-resolution images taken by drones are being used for a variety of information, including monitoring. The management of agricultural facilities still uses mostly human survey methods. Surveying agricultural facilities, surveying the appearance of agricultural facilities, and the sleeping environment have legal and environmental constraints that are inaccessible to humans. In addition, in an area where information such as 3D maps and satellite maps are outdated or not provided, human investigation is inevitable, and a lot of time and money are invested. The purpose of this research is to design and develop drone system for field support incorporating AR smart glasses technology for the maintenance and management of agricultural facilities to improve the difficulties of using existing drones. In addition, We will also suggest ways to secure the safety of personal information in order to solve the damages caused by the exposure of personal information that may occur through video shooting.

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.