• Title/Summary/Keyword: Facility maintenance

Search Result 872, Processing Time 0.024 seconds

Performance Evaluation Method of Tunnel Scanner for Lining Crack Detection (터널 균열 검출에 활용되는 터널스캐너의 성능검증 방법론)

  • Bae, Sung-Jae;Jung, Wook;Chamrith, Sereivatana;Kim, Chan-Jin;Kim, Young-Min;Hong, Sung-Ho;Kim, Jung-Gon;Kim, Jung-Yeol
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.39-52
    • /
    • 2021
  • Purpose: Recently, due to increasing usage of high-tech equipment for facility inspection, the need of verifying high-tech equipment is being emphasized. Therefore, the purpose of this paper is to develop performance evaluation methodology of tunnel scanners that inspect tunnel facilities. Method: This paper describes literature reviews regarding the performance evaluation methodology of high-tech based equipment for facility inspection. Based on these investigations and expert advisory meetings, this paper suggests a performance evaluation methodology of tunnel scanner. Result: First evaluation indicator states minimum performance standards of tunnel scanners. Second evaluation indicator is related to tunnel scanner quality. Conclusion: The performance evaluation methodology can provide reliable equipment performance catalogues, helping users to make a proper selection of equipment. Also, developers of equipment can get authorized verification of performances, preventing poor maintenance of facilities.

Analysis between Computer Simulation and Real-car Crash Test of Energy Absorption Facilities for Various Road Environments (다양한 환경에 적용 가능한 충격흡수시설의 시뮬레이션 분석 및 실물충돌시험 결과 분석)

  • No, Min Hyung;Park, Jea Hong;Seo, Chang Won;Sung, Jung Gon;Yun, Duk Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.399-407
    • /
    • 2022
  • Energy absorption facilities installed on roads should follow the performance standards of the real-car crash test of 'Installation and Maintenance Guidelines for Roadside Safety Facilities'. However, due to different installation conditions, such as differing structure widths on roads, some energy absorption facilities do not provide adequate performance. In order to apply varied environments on roads, an energy absorption structure was designed in this study with 150 mm height and four layers of W-shape guardrail at 200 mm intervals, and the performance was verified using LS-DYNA computer simulation. Through a real-car crash test, the performance of the facility designed by LS-DYNA was tested and was found to meet the performance of the CC2 category for crash cushions. The conclusion of the comparison demonstrates that the simulation and the real-car crash tests are both significant.

Study on the Improvement of Water Regeneration Center by Using Non-water-soluble Sanitary Products: Focusing on the case of Seoul City (비수용성 위생용품 사용에 따른 물재생센터 개선방안: 서울시를 중심으로)

  • Choong-Gon Kim;Yoon-Hwan Bae;Hyun-Gon Shin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.2
    • /
    • pp.39-44
    • /
    • 2023
  • This study was conducted to analyze problems related to non-water-soluble sanitary products during the treatment of water regeneration centers in E.T.F. and S.T.F. at a time when the demand and supply of non-water-soluble sanitary products are increasing. As a result, the improvement plan of the W.R.C. should focus on pretreatment facilities. When replacing facilities in the future, various dust removers suitable for the facility's reality will be installed in the pretreatment of S.T.F., and it is proposed to link a bar-racks screen with a comprehensive treatment device or install a comprehensive treatment device for impurities alone in the pretreatment of E.T.F.. In addition, a microscreen screen must be installed on the front end of the excretory treatment unit. to separate non-water-soluble materials, and it is necessary to secure a maintenance space for the excretory treatment unit.

Efficient Evaluation Method of Operation Cost for Wastewater Treatment Plant by BTL Contract Type (하수처리시설 BTL사업의 합리적인 운영비 산정방안)

  • Kang, Leen Seok;Yoon, Sun MI;Kwon, Joong Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5D
    • /
    • pp.627-634
    • /
    • 2009
  • The BTL (Build-Transfer-Lease) contract of construction project serves as a part for early establishment of industrial foundation for social overhead capital. However, project cost of BTL contract is focused on initial construction cost. Accordingly, operation cost is lowly evaluated because there is no standard criterion for estimating maintenance cost for the facility. The low operation cost can be a factor that reduces service quality of facility operation. This study suggests a resonable method for estimating cost and manpower in the operation phase by using the existing practical data for wastewater treatment plant by BTL contract. The results of the study can be used for evaluating rough operation cost and manpower of similar plant project by facility size.

Lifecycle cost assessment of best management practices for diffuse pollution control in Han River Basin (한강수계 비점오염원 저감시설의 생애주기비용 평가)

  • Lee, Soyoung;Maniquiz-Redillas, Marla C.;Lee, Jeong Yong;Mun, Hyunsaing;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.448-455
    • /
    • 2016
  • Diffuse pollution management in Korea initiated by the Ministry of Environment (MOE) resulted to the construction of pilot facilities termed Best Management Practices (BMPs). Twelve BMPs installed for the diffuse pollution management in the Kyung-An Stream were monitored since 2006. Data on the mass loading, removal efficiency, maintenance activities, etc. were gathered and utilized to conduct the evaluation of long-term performance of BMPs. The financial data such as actual construction, design and maintenance cost were also collected to evaluate the lifecycle cost (LCC) of BMPs. In this study, most of the maintenance activity was focused in the aesthetic maintenance that resulted to the annual maintenance cost of the four BMP types was closely similar ranging from 8,483 $/yr for retention pond to 8,888 $/yr infiltration system. The highest LCC were observed in constructed wetland ($418,324) while vegetated system had the lowest LCC ($210,418). LCC of BMPs was not so high as compared with the conventional treatment facility and sewage treatment plant. On the other hand, the relationship of removal efficiency on unit cost for TSS and TN was significant. This study will be used to design the cost effective BMP for diffuse pollution management and become models for LCC analysis.

Study of Monitoring Methods for Maintenance Management of Tailings Dams (광물찌꺼기 적치장 유지관리를 위한 모니터링 방안 연구)

  • Oh, Sam-Ju;Kim, Ki-Joon;Song, Jea-Yong;Choi, Uikyu
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.473-484
    • /
    • 2016
  • This study aims to establish a monitoring method for managing the effective maintenance of tailings dams. The monitoring of a tailings dump area involves several parameters and their investigation through a selection of evaluation items. The extents of defects and progressive failures also need to be effectively estimated. Therefore, the monitoring items can be subdivided into categories relating to the retaining wall structure (concrete wall, reinforcing stone wall, mesh gabions) and general facilities (liner, covering soil, slope, tailings, rain protection facility, leachate, planting), and quantitative evaluations can then be conducted for each condition. In doing so, we developed a systematic monitoring method that assesses the dam maintenance condition with grades and scores. The field application of the monitoring method results showed it to provide a more detailed evaluation than existing monitoring methods: the method detected an additional 16 defects missed by conventional methods. The evaluation gave scores of 89.3, 22.2, and 27.8 to the Geumjang mine tailings dam, the Gupoong mine tailings dam, and the Hwachun mine tailings dam, respectively. The advanced method can provide quantitative evaluation and perform detailed monitoring of the dams. This quantitative evaluation can be used to decide on maintenance priorities, select the main management items, and establish schedules of maintenance.

A study on smart inspection technologies and maintenance system for tunnel (터널 스마트 점검기술 및 유지관리 제도 분석에 관한 연구)

  • Jee-Hee Jung;Kang-Hyun Lee;Sangrae Lee;Bumsik Hwang;Nag-Young Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.569-582
    • /
    • 2023
  • In recent years, the service life of major SOC facilities in south korea has exceeded 30 years, and rapid aging is expected within the next 10 years. This has led to a growing recognition of the need for proactive maintenance of these facilities. Consequently, there have been numerous research efforts to introduce smart inspection technologies into maintenance. However, the current system relies primarily on manpower for safety inspections and diagnostics, and on-site surveys rely on visual inspections. Manpower inspections can be time-consuming, and subjective errors may occur during result analysis. In the case of tunnels, there are disadvantages, such as the loss of social overhead capital due to partial closures during inspections. Therefore, institutionalizing smart safety inspections is essential, considering specific measures like using advanced equipment and updating qualifications for experts. Furthermore, it is necessary to verify and validate safety inspection results using advanced equipment before instituting changes. This could be achieved through national-level official research programs and the operation of verification and validation institutions. If smart inspection technology is introduced into maintenance, routine inspections of SOC facilities, such as tunnels, will become feasible. As a result, maintenance technology capable of early detection and proactive response to safety incidents caused by changes in facility conditions is anticipated.

Validity Evaluation of Real Time Mobile GIS combined with PDA in University Building Facility Management (대학시설물 관리W떠 PDA기반의 실시간 Mobile GIS 도입 타당성 평가)

  • 정지훈;엄정섭
    • Spatial Information Research
    • /
    • v.11 no.1
    • /
    • pp.41-60
    • /
    • 2003
  • It is noted that the paper mapping system for University Building Facility has many limitations in terms of data maintenance, real-time GIS data acquisition, and economic efficiency. The aim of this research was to evaluate an operational potential of an on site real-time mobile GIS technique to resolve the problem faced in the university. The idea is based upon the recent trends in the field of 'Telecommunication and Information Technology' that uses a PDA (personal Digital Assistants), wireless network computing, mobile computing, etc. A real time mobile GIS approach has been adopted, in which a PDA is linked to a wireless internet and field workers record data on the computer at the site and analyse data on site. While there should be a considerable number and variety of factors associated with real-time mobile GIS quality, this research focuses on three criteria that are identified as fundamental to customer requirements; (1) data quarry (2) spatial analysis (3) real-time GIS database building. 'Art--empirical study for a case study facility has been conducted to confirm the validity for the system. The system has been checked experimentally, enabled the field users to quarry the data required simply and execute spatial analysis (buffer, overlay etc.,) accommodating versatile alternatives on the site. Detailed visual maps can be generated over large areas quickly and easily. The PDA interface, in particular, were ideally suited for field users to interactively displaying positional information with attribute data. This system has shown to be quite convenient to maintaining a highly reliable database since it could playa crucial role in documenting at real-time basis temporal and spatial changes occurred in the facilities. It is anticipated that this research output will greatly serve to introduce the reliable and cost-effective facility mapping system in the university by overcoming serious constraints suffered from the past non-real time mobile GIS approach.

  • PDF

A Study on the Fire Design Business Development Direction (소방시설설계업의 발전방향에 관한 연구)

  • Hong, Sung-Woo;Lee, Young-Jae;Park, Hung-Joo
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.67-72
    • /
    • 2009
  • For the fire-fighting industry to advance, it is necessary to conduct research on which parts of the fire-fighting law should be changed from the system level, and to study the opinions of the fire-fighters whoa re working in the fire-fighting industry today, and to identify what needs to be changed. Moreover, it is necessary to become aware on the preventive measures to take to avoid fire so that the citizens can lead stable life. Design business among the fire-fighting facility business, it is the fire-fighting facility business that serves as the most basic when constructing building structure. This is an important legal matter that follows the fire-fighting business, fire-fighting audit business and even the maintenance and management business. This research sought to help the fire-fighting industry to contribute to the life of the general public and to increase welfare by identifying the problems pertaining to the fire-fighting facility design business among the fire-fighting industry so that the industry can become the fire-fighting industry that the citizens are interested in. Moreover, direction for advancement is proposed. As for the improvement measures for the fire-fighting policy pertaining to the fire-fighting facility design business, it is divided into the machinery and electricity fields in terms of the legal system pertaining to the general fire-fighting facility design business. Likewise, specialty in design is deficient. Thus, it should be integrated in a systematic level to contribute to the safety of the general public.

The Research about Role Area of RT in Digital Environment - Centers on PACS Workplace -

  • Jung, Young-Tae;Park, Bum-Jin;Son, Gi-Gyeong;Jung, Jae-Ho;Kang, Hee-Doo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.13-20
    • /
    • 2011
  • Now a days in our society, occupation boundaries have become blurred, and come into the limelight in the prior occupation or miss about new workplace. Medical area is no exception also, So we face urgent problem about protecting and spreading RT work-sphere simultaneously. This research allow to identify on RT role area of digital environment that is obscure profession-realm specially, and open up a new field hereafter. We examined present RT role area of digital environment in the more than thirty medical facility(general or university hospital) through questionnaire/visit survey from PACS administrator. Survey sentence comprises total 29 sentence over all main quadrisection-(eX. hospital formation & treatment state and PACS team composition & organization and PACS team workplace and PACS team daily workload), We performed comparative analysis in general contents perspectively. further more, divided main 5 section based on upper analysis and then manufactured output in consideration of each medical facility's operation state. There are comparative problem of hospital policy, So we maintained information security of each facility exhaustively. First, we separated a survey output into main 5 section as follows-(eX. PACS server & maintenance manage, Client/interlock manage, PACS data conversion, 3D reconstruction, PACS data im/export)-that received by 35 medical facility. And then manufactured output with comparative analysis about RT role area each section, general IT managing team about medical environment was out of existence that fill up with RT manpower in the surveyed medical facility consequently. What is worse, hospitals that entirely fill up with another worker were 3 place amazingly. Our specific statistic results show, the respondents was 63% that agree with reorganization of formation base on independence team, and supplement of the personnel average -continuous with upper agreement simply-was about 2.64. Further more, if reorganization break out with only RT manpower, quota TO will increase by geometric progression. Protecting and spreading role workplace is much accounted of the our inevitable project surely and more than 95% PACS administrator's have confidence in this proposition unconditionally. Henceforth, look forward to meeting the RT vision of many-sided multiplayer, based on acquire a specialized IT knowledge actively and open up a new work-field with frontier spirit.

  • PDF