• Title/Summary/Keyword: FRP(fiber reinforced plastic)

Search Result 177, Processing Time 0.026 seconds

Location Problem on the Treatment Facility of Waste FRP Ships (폐 FRP 선박 처리시설 입지선정문제)

  • Park, HyunJi;Shin, JaeHun;Kim, KiDong
    • Journal of Industrial Technology
    • /
    • v.38 no.1
    • /
    • pp.9-13
    • /
    • 2018
  • FRP(Fiber Reinforced Plastic) ships are easy to manufacture and repair. Also they are more durable and cheaper than steel wires and neck lines. Therefore FRP ships are widely used in small ships. In Korea, the amount of waste FRP ships is increasing. It is expected that a large amount of waste FRP ships will be generated. Waste FRP ships are emerging as a social problem, such as the difficulty in preserving the marine environment. To improve this, a waste FRP ship melting process system has been developed. In order to construct an effective waste FRP ship processing system, it is necessary to study the treatment facilities location problem. In this paper, we suggest mathematical model to solve optimal location problem of waste FRP Ships and discuss on results by applying it to nine regions selected as candidates for treatment facilities.

The Development and Field Test of DC FRP Support Insulator Prototype (직류용 FRP 지지애자 개발 및 현장설치 적응시험)

  • Sim, Jae-Suk;Kim, Yoon-Sik;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1979-1983
    • /
    • 2011
  • FRP(Fiber Reinforced Plastic) support insulators for DC(direct current) were developed and their electrical and mechanical characteristics were investigated. Electrical tests were carried out to measure flashover voltages under common use frequency condition. Tensile and bending tests were performed for the mechanical characteristics. The test results showed that FRP support insulators have superior voltage resistances and strengths to porcelain insulators. Field test also is carried out to measure adaptation and to compensate the defect. The test result showed that a new product has no defect in electrical and mechanical.

  • PDF

Comparison Analysis on Status of Domestic & Overseas Vessel Fire Accident and Relevant Standards for the Fire Retardant Structure (국내외 화재발생현황 및 관련 방화구조 기준 비교 분석)

  • Um, Han-Chan
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.38
    • /
    • pp.12-21
    • /
    • 2015
  • 유리강화섬유(FRP,Fiber Reinforced Plastic)은 가볍고 내구성등이 우수하여 가공하기 쉬워 선박건조, 특히 어선의 건조재료로 많이 활용되고 있으나, FRP의 재료인 매트와 로빙이 인화성을 가진 수지와 접합되어 화재에는 매우 취약한 특성을 가지는 특성을 가진다. 최근 10년간의 중앙해양안전심판원의 어선화재 재결서 분석결과 전체의 약80%에 해당하는 화재사고가 기관실에서 발생하였다. 이에 새로 출범한 해양수산부는 FRP선박의 구조기준을 개정하여 총톤수10톤 이상 선박의 기관실에 대한 방화조치를 그 이하선박까지로 적용 확대하였으며, 어선구조기준 역시 행정규칙 행정예고를 통해 강화하려는 움직임을 보이고 있다. 본 지에서는 국내외 화재사고 발생현황 및 관련 규제 내용을 비교 분석하여 제시하였으며 분석결과, 일반선박의 방화조치에 대한 규제는 거의 유사하였으나 어선관련 규제의 경우, 영국의 규제가 가장 강화되어 있었으며 관련 화재사고 발생현황도 국내 및 일본과 비교해 보았을때 같은 기간 발생한 일반선의 화재발생척수 대비 어선의 화재발생척수가 적은것을 확인할 수 있었다.

  • PDF

The Performance Test and Mechanical Strength Analysis for 154kV Hollow Composite Insulator (154kV급 Hollow Composite Insulator의 기계적 강도해석 및 특성시험)

  • Park, Ki-Ho;Cho, Han-Gu;Han, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.495-498
    • /
    • 2002
  • This paper describes the results the problem of stress calculation and optimization into a FRP(Fiber-glass Reinforced Plastic) tube crimped into a metal end-fitting. This type of assembly is used mainly is used mainly for suspension and line post insulators. Fitting strength of FRP and flange of this study is required greatly from composite insulator to important special quality. Therefore, wish to seek analysis and mechanical strength performance that follow to FRP tube and flange of top and bottom mechanical fitting.

  • PDF

A Study on the Flexural Analysis of FRP Plate to Develop Fabricated Permanent Soil Nailing System (조립식 영구 쏘일네일링 공법의 개발을 위한 FRP평판의 휨해석에 관한 연구)

  • Choi, H.;Joo, H.J.;Nam, J.H.;Yoon, S.J.
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.180-183
    • /
    • 2005
  • Application of the soil nailing system is continuously extended to stabilize excavations and slopes. Although there are many applications in the construction site, the system is still needed to improve its mechanical performance and durability. So, the use of FRP for this system can be an alternative for the conventional system. Recently, there has been a greatly increased demand for the use of FRP (fiber reinforced plastic) in civil engineering applications due to their superior mechanical and physical properties. This paper presents an experimental and theoretical study on the flexural behavior of FRP plate to develop fabricated permanent soil nailing system. In this study, mechanical properties of FRP plate have been investigated. Rectangular FRP plates that is simply supported and uniformly loaded over the area of a circle at the center of plate are analyzed by experiment, classical plate theory, and finite element method. From the results of analysis we can determine the shape of curved FRP plate which will exert certain amount of prestressing force in soil nail.

  • PDF

Characteristics of Flexural Capacity and Ultrasonic in RC member with Corroded Steel and FRP Hybrid Bar (부식된 FRP Hybrid Bar의 휨 내력 및 초음파 속도 특성)

  • Choi, Se-Jin;Mun, Jin-Man;Park, Ki-Tae;Park, Cheol-Woo;Kwon, Seung-Jun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.397-407
    • /
    • 2015
  • Concrete is a attractive construction material, however durability problem occur due to steel corrosion, which leads propagation to structural safety problem. The recently developed FRP (Fiber Reinforced Plastic) Hybrid Bar has an engineering merit of both structural steel and FRP. Accelerated corrosion test for RC (Reinforced Concrete) samples with normal steel and FRP Hybriud Bar are performed and their flexural capacity is evaluated. Furthermore UV(Ultrasonic Velocity) measurement is attempted for analysis of variation of UV due to corrosion condition. After corrosion test, there is no significant reduction in RC beam with FRP hybrid bar but 11.5% of reduction in the case of normal steel is evaluated with 3.3% of UV reduction. For commercial production of FRP hybrid bar, bond strength evaluation through long-term submerged corrosion is required.

Strength toss of F-Fiber Obtained from Recycling FRP Ship in a Basic Solution (폐 FRP 선박에서 분리하여 얻은 F섬유의 염기성 용액에서의 강도저하)

  • Lee, Seung-Hee;Kim, Yong-Seop;Yoon, Koo-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.1
    • /
    • pp.42-45
    • /
    • 2008
  • It has been reported that FRP (fiber reinforced plastic) can be recycled by separating into layers instead of crushing into powder. F-fiber obtained from roving layer separated from FRP, has bigger tensile strength than the bundle of glass fibers of which FRP was made (more than 90%). SEM image of F-fiber shows the presence of some resin. Under the proposition of usage of F-fiber in the concrete material, tensile strength is examined after soaking in a basic solution (NaOH+KOH). The reaction mechanism of strength loss may be considered as an attack of hydroxide ion ($OH^-$) on a chemical bond of Si-O-Si of glass fiber. The simulation graph of the strength loss data implies certain reaction mechanism. While in the early stage kinetically controlled reaction results in a fast drop of tensile strength, after 30 days dispersion rate of hydroxide ion plays a major role in strength loss. This result is similar to the one for the AR glass. An extrapolation of the graph would make an assumption about the lift time of F-fiber possible.

  • PDF

An Analytical Study on the Buckling of Orthotropic Plates and Local Buckling of Compression Members (직교이방성 판의 좌굴 및 압축재의 국부좌굴에 대한 해석적 연구)

  • Choi, Jin-Woo;Lee, Kang-Yeon;Park, Jung-Hwan;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • In this paper, we present the analytical study results pertaining to the buckling of the orthotropic plates and local buckling of structural compression members composed of orthotropic plate components. Fiber reinforced polymeric plastic (FRP) materials, have many advantages over conventional structural materials such as steel and concrete. The advantages of the FRP materials are high specific strength and stiffness, high corrosion resistance, right weight, etc. Among the various manufacturing methods, pultrusion process is one of the best choices for the mass production of structural plastic members. Since the major reinforcing fibers are placed along the axial direction of the member, this material is usually considered as an orthotropic (tranversely isotropic, more specifically) material. However, pultruded fiber reinforced plastic structural members have low modulus of elasticity and are composed of orthotropic thin plate components the members are prone to buckle. Therefore, stability is an important issue in the design of the pultruded FRP structural members. In this paper, the buckling of orthotropic plates and the local buckling of pultruded FRP structural members are investigated by following the previous research results and the local buckling strength of the member produced in the domestic manufacturer is found.

Numerical Study of the Formability of Fiber Metal Laminates Based on Self-reinforced Polypropylene (자기 강화형 폴리프로필렌을 이용한 섬유 금속 적층판의 성형성에 관한 수치해석적 연구)

  • Lee, B.E.;Kim, J.;Kang, B.S.;Song, W.J.
    • Transactions of Materials Processing
    • /
    • v.22 no.3
    • /
    • pp.150-157
    • /
    • 2013
  • Fiber metal laminates (FMLs) are layered materials comprised of thin metal sheets and fiber reinforced plastic (FRP). This paper presents the numerical study of the formability enhancement of FMLs composed of an aluminum alloy and self-reinforced polypropylene (SRPP) composite. In this study, a numerical simulation based on finite element (FE) modeling is proposed to evaluate the formability of FMLs using ABAQUS/Explicit. The FE model, which included a single layer of solid and shell elements to model the blank, used discrete layers of the solid element with a contact model and shell elements with a friction based model for the aluminum alloy-composite interface conditions. This method allowed the description of each layer of FMLs and was able to simulate the interaction between the layers. It is noted through this research that the proposed numerical simulation described properly the formability enhancement of the FMLs and the simulation results showed good agreement with experimental results.

Experimental Investigations on the Flexural Behavior of One-Way Concrete Slabs Reinforced with GFRP Re-Bar Bundle (유리섬유 보강 플래스틱 Re-Bar 다발로 보강된 1방향 콘크리트 슬래브의 휨거동에 관한 실험적 연구)

  • 윤순종;김병석;유성근;정재호;정상균
    • Composites Research
    • /
    • v.16 no.3
    • /
    • pp.32-40
    • /
    • 2003
  • In recent years, the investigation on the development of fiber reinforced plastic(FRP) Re-Bar has been greatly increased due to the attractive physical and mechanical properties of FRP. The primary reason of such a tendency is in the fact that it does not ordinarily cause durability problems such as those associated with steel reinforcement corrosion. This study is an experimental investigation on the flexural behavior of one-way concrete slabs, which can be used to construct bridge deck, reinforced with GFRP Re-Bar bundle. The tensile tests of GFRP Re-Bar produced by domestic industry and third point bending tests of one-way slab specimens reinforced with GFRP Re-Bar bundle are peformed. For all slab specimens, load-deflection relations are predicted by using the ACI committee 440 and the results are compared with experimental ones. In order to establish the design criteria or guidelines of concrete flexural member reinforced with FRP Re-Bar, it is needed to evaluate the serviceability limit state as well as the strength limit state.