• Title/Summary/Keyword: FLASH3D

Search Result 182, Processing Time 0.023 seconds

The 1/f Noise Analysis of 3D SONOS Multi Layer Flash Memory Devices Fabricated on Nitride or Oxide Layer (산화막과 질화막 위에 제작된 3D SONOS 다층 구조 플래시 메모리소자의 1/f 잡음 특성 분석)

  • Lee, Sang-Youl;Oh, Jae-Sub;Yang, Seung-Dong;Jeong, Kwang-Seok;Yun, Ho-Jin;Kim, Yu-Mi;Lee, Hi-Deok;Lee, Ga-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.85-90
    • /
    • 2012
  • In this paper, we compared and analyzed 3D silicon-oxide-nitride-oxide-silicon (SONOS) multi layer flash memory devices fabricated on nitride or oxide layer, respectively. The device fabricated on nitride layer has inferior electrical properties than that fabricated on oxide layer. However, the device on nitride layer has faster program / erase speed (P/E speed) than that on the oxide layer, although having inferior electrical performance. Afterwards, to find out the reason why the device on nitride has faster P/E speed, 1/f noise analysis of both devices is investigated. From gate bias dependance, both devices follow the mobility fluctuation model which results from the lattice scattering and defects in the channel layer. In addition, the device on nitride with better memory characteristics has higher normalized drain current noise power spectral density ($S_{ID}/I^2_D$>), which means that it has more traps and defects in the channel layer. The apparent hooge's noise parameter (${\alpha}_{app}$) to represent the grain boundary trap density and the height of grain boundary potential barrier is considered. The device on nitride has higher ${\alpha}_{app}$ values, which can be explained due to more grain boundary traps. Therefore, the reason why the devices on nitride and oxide have a different P/E speed can be explained due to the trapping/de-trapping of free carriers into more grain boundary trap sites in channel layer.

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF

Long-Term Effects of the DHA Supplementation on Physical and Brain Development in Full-Term Infants (장기간에 걸친 DHA 보충이 영아의 신체발육 및 두뇌발달에 미치는 영향)

  • 정현주
    • Journal of Nutrition and Health
    • /
    • v.31 no.8
    • /
    • pp.1295-1306
    • /
    • 1998
  • Recent research indicates that the n-3 fatty acid , docosahexaenoic acid(22 : 6n 3, DHA) plays an essential role in infant brain development . DHA is highly concentrated in brain and retinal tissues and accumulates during late fetal and early neonatal life. Diets deficient in DHA are associated with reduced levels of DHA in brain and retinal tissues. The purpose of this study is to investigate the long term effects of DHA supplementation on the growth and mental development of full-term infants. THirty four healty infants were recruited from those who were delivered at Kyung Hee Medical Center. The experimental groups were the breast milk+DHA(-) group who were fed human milk for 20 weeks after birth and thereafter were fed placebo formula for 28 weeks, the breast milk+DHA(+) group who were fed human milk for 20 weeks after birth and thereafter were fed DHA supplemented formula for 28 weeks, DHA(-) group who were fed placebo formula for 48 weeks, and DHA(+) group who were fed DHA supplemented formula for 48 weeks. The daily average intake of DHA for the breast milk+DHA(-) , breast milk+DHA(+), DHA(-) and DHA(+) groups were 39.1mg, 89.9mg, 17.7mg, and 160.224mg, respectively. The results showed that measurements of infant weight, length, head, and chest circumferncewere all in normal range and they were not influenced by the DHA supplements in their diets. There was a significant correlation between dietary DHA intake and erythrocyte DHA level. The results of flash visual evoke potential (VEP) test were not correlated with eerythrocyte DHA and dietary DHA levels at 48 weeks of age. No differences were found in Bayley mental and Psychomotor Development lndex scores among the four experimental groups at 48 weeks of age. Unlike the short-term effects there was no long-term effect of relatively small amounts of dietary DHA supplements on the scores for flash VEP and Bayley test, even thour호 there was an elevated DHA supplements on the scores for flash VEP and Bayley test, even through there was an elevated DHA content in the infants erythrocytes.

  • PDF

Multi-scale wireless sensor node for health monitoring of civil infrastructure and mechanical systems

  • Taylor, Stuart G.;Farinholt, Kevin M.;Park, Gyuhae;Todd, Michael D.;Farrar, Charles R.
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.661-673
    • /
    • 2010
  • This paper presents recent developments in an extremely compact, wireless impedance sensor node (the WID3, $\underline{W}$ireless $\underline{I}$mpedance $\underline{D}$evice) for use in high-frequency impedance-based structural health monitoring (SHM), sensor diagnostics and validation, and low-frequency (< ~1 kHz) vibration data acquisition. The WID3 is equipped with an impedance chip that can resolve measurements up to 100 kHz, a frequency range ideal for many SHM applications. An integrated set of multiplexers allows the end user to monitor seven piezoelectric sensors from a single sensor node. The WID3 combines on-board processing using a microcontroller, data storage using flash memory, wireless communications capabilities, and a series of internal and external triggering options into a single package to realize a truly comprehensive, self-contained wireless active-sensor node for SHM applications. Furthermore, we recently extended the capability of this device by implementing low-frequency analog-to-digital and digital-to-analog converters so that the same device can measure structural vibration data. The compact sensor node collects relatively low-frequency acceleration measurements to estimate natural frequencies and operational deflection shapes, as well as relatively high-frequency impedance measurements to detect structural damage. Experimental results with application to SHM, sensor diagnostics and low-frequency vibration data acquisition are presented.

A 12b 100MS/s 1V 24mW 0.13um CMOS ADC for Low-Power Mobile Applications (저전력 모바일 응용을 위한 12비트 100MS/s 1V 24mW 0.13um CMOS A/D 변환기)

  • Park, Seung-Jae;Koo, Byeong-Woo;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.8
    • /
    • pp.56-63
    • /
    • 2010
  • This work proposes a 12b 100MS/s 0.13um CMOS pipeline ADC for battery-powered mobile video applications such as DVB-Handheld (DVB-H), DVB-Terrestrial (DVB-T), Satellite DMB (SDMB), and Terrestrial DMB (TDMB) requiring high resolution, low power, and small size at high speed. The proposed ADC employs a three-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. A single shared and switched op-amp for two MDACs removes a memory effect and a switching time delay, resulting in a fast signal settling. A two-step reference selection scheme for the last-stage 6b FLASH ADC reduces power consumption and chip area by 50%. The prototype ADC in a 0.13um 1P7M CMOS technology demonstrates a measured DNL and INL within 0.40LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 60.0dB and a maximum SFDR of 72.4dB at 100MS/s, respectively. The ADC with an active die area of 0.92 $mm^2$ consumes 24mW at 1.0V and 100MS/s. The FOM, power/($f_s{\times}2^{ENOB}$), of 0.29pJ/conv. is the lowest of ever reported 12b 100MS/s ADCs.

A Re-configurable 0.8V 10b 60MS/s 19.2mW 0.13um CMOS ADC Operating down to 0.5V (0.5V까지 재구성 가능한 0.8V 10비트 60MS/s 19.2mW 0.13um CMOS A/D 변환기)

  • Lee, Se-Won;Yoo, Si-Wook;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.3
    • /
    • pp.60-68
    • /
    • 2008
  • This work describes a re-configurable 10MS/s to 100MS/s, low-power 10b two-step pipeline ADC operating at a power supply from 0.5V to 1.2V. MOS transistors with a low-threshold voltage are employed partially in the input sampling switches and differential pair of the SHA and MDAC for a proper signal swing margin at a 0.5V supply. The integrated adjustable current reference optimizes the static and dynamic performance of amplifiers at 10b accuracy with a wide range of supply voltages. A signal-isolated layout improves the capacitor mismatch of the MDAC while a switched-bias power-reduction technique reduces the power dissipation of comparators in the flash ADCs. The prototype ADC in a 0.13um CMOS process demonstrates the measured DNL and INL within 0.35LSB and 0.49LSB. The ADC with an active die area of $0.98mm^2$ shows a maximum SNDR and SFDR of 56.0dB and 69.6dB, respectively, and a power consumption of 19.2mW at a nominal condition of 0.8V and 60MS/s.

The Role of Dynamic Contrast Enhanced MR Mammography in Differentiation between Benign and Malignant Breast Lesions

  • 한송이;차은숙;정상설;김학희;변재영;이재문
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.135-135
    • /
    • 2002
  • Purpose: To assess diagnostic accuracy of dynamic contrast enhanced MR mammography in differentiating between benign and malignant lesions. Materials and methods: Ninety-three patients with suspicious mammographic, sonographic or palpable findings underwent pre- or postoperative contrast-enhanced MR imaging of breast using three dimensional fast low-angle shot (3D FLASH) sequence (16/4 msec[repetition time / echo time], 20 flip angle, 3mm slice thickness with no slice gap, 256 by 256 in-plane matrix) covering whole breasts. T1 weighted images were obtained before and after bolus administration of gadopentetate dimeglumine (0.15 mmol/kg). Subtraction images and time-signal intensity curves of region of interest were obtained sequentially and correlated with pathologic diagnoses of lesions.

  • PDF

Study of Program and Erase Characteristics for the Elliptic GAA SONOS Cell in 3D NAND Flash Memory (3차원 낸드 플레쉬에서 타원형 GAA SONOS 셀의 프로그램과 삭제 특성 연구)

  • Choi, Deuk-Sung;Lee, Seung-Heui;Park, Sung-Kye
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.219-225
    • /
    • 2013
  • Program and erase characteristics of the elliptic gate all around (e-GAA) SONOS cell have been studied as the variation of eccentricity of the channel. An analytic program and erase model for the elliptic GAA SONOS cell is proposed and evaluated. The model shows that the ISPP (incremental-step-pulse programming) property is changed non-linearly as the eccentricity of the e-GAA SONOS cell is increased. It is differently from the well known linear relationship for that of 2D SONOS and even 3D circular SONOS cell with program bias. We can find that the simulation results of ISPP characteristics are in accord with the experimental data.

Design of a Portable Activity Monitoring System (휴대용 활동 상태 모니터링 시스템의 설계)

  • Lee, Seung-Hyung;Park, Ho-Dong;Yoon, Hyung-Ro;Lee, Kyung-Joung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.1
    • /
    • pp.32-38
    • /
    • 2002
  • This paper describes a development of a portable physical activity monitoring system using two accelerometers to quantify physical activity. The system hardware consists of two piezoresistive accelerometers, amplifiers with gain of 30, lowpass filters with cut-off frequency of 15Hz, offset control circuits, one-chip microcontroller and flash memory card. In order to evaluate the performance of the system we acquired 3 channel data at 32 sample/sec from body-fixed accelerometers in chest and right upper leg. And then the acquired data were processed by MatLab on personal computer. We tried to distinguish not only fundamental actions which are steady-state activities such as standing, sitting, and lying but also dynamic activities with walking, up a stairway, down a stairway, and running. Five subjects participated the evaluation process which compare the video data with the measured data. As a result, the activity classification rate of 90.6% on average was obtained. Overall results showed that the steady-state activities could be classified from the low component of 3-axis acceleration signal and dynamic activities could be distinguished from frequency analysis using wavelet transform and FFT. Finally, we could find that this system can be applied to acquire and analyze the static and dynamic physical activity data.

Production and Biodegradability of Biodiesel from Balanites Aegyptiaca Seed Oil (Balanites Aegyptiaca 씨기름으로부터 바이오디젤의 생산과 생분해성 연구)

  • Jauro, Aliyu;Adams, Momoh Haruna
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.4
    • /
    • pp.680-684
    • /
    • 2011
  • Seed oil of Balanites aegyptica was transesterified to produce biodiesel and its quality and biodegradability assessed. The specific gravity (SG), density and flash point of the methyl esters were found to be 0.897, 0.89 g/$cm^3$ and $163^{\circ}C$ respectively. Biodegradability of the biodiesel assessed by the standard $CO_2$ evolution method using two different inoculums revealed that the Balanites aegyptica biodiesel was readily biodegradable in both inoculums (82.58% and 86.98%), compared with the $D_2$ diesel which was partially biodegradable (27.02% and 27.33%). These suggest that Balanites aegyptiaca seed oil is a potential source of environmentally friendly biodiesel.