• Title/Summary/Keyword: Extra Capacity

Search Result 117, Processing Time 0.033 seconds

Robust Capacity Planning in Network Coding under Demand Uncertainty

  • Ghasvari, Hossien;Raayatpanah, Mohammad Ali
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.8
    • /
    • pp.2840-2853
    • /
    • 2015
  • A major challenge in network service providers is to provide adequate resources in service level agreements based on forecasts of future demands. In this paper, we address the problem of capacity provisioning in a network subject to demand uncertainty such that a network coded multicast is applied as the data delivery mechanism with limited budget to purchase extra capacity. We address some particular type of uncertainty sets that obtain a tractable constrained capacity provisioning problem. For this reason, we first formulate a mathematical model for the problem under uncertain demand. Then, a robust optimization model is proposed for the problem to optimize the worst-case system performance. The robustness and effectiveness of the developed model are demonstrated by numerical results. The robust solution achieves more than 10% reduction and is better than the deterministic solution in the worst case.

Test results confirm the bridge foundation bearing capacity due to construction costs case (교량기초의 지지력확인 시험 결과에 따른 건설비 절감사례)

  • Lee, Soo-Gon;Woo, Jae-Gyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1065-1072
    • /
    • 2010
  • Case studies published in Korea versus the low ground fault is applied on the bridge based on theory or experience in the design of pile bearing capacity by the value of the expression is designed to conduct field tests Disclosure Load bearing capacity value, the result of applying a reasonable construction cost savings of approximately 10 eokyeowon Has, in the design of site investigation was insufficient to require additional efforts. Apply the appropriate value from the extra support in the design of accurate ground survey and air speed to cut the budget and social technology can ensure the reliability was unknown.

  • PDF

An Examination on capacity of heat source system and the operating rate for safety factor in office building (사무소 건물 열원기기 용량과 가동률에 대한 안전율의 적정성 검토)

  • Ha, Jong-Sung;Lee, Dong-Soo;Cha, Bong-Min;Jang, Jong-Woon;Kim, Se-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.512-518
    • /
    • 2006
  • Economize the energy, further study is highly needed at the very beginning stage of the building plan. To fulfill this study, research of the buildings in Busan will be carried out, and find out the relations between pure load of buildings and capacity of heat & cooling equipment. Therefore this study is suggesting better idea of calculating capacity from having a thorough grasp of the problem with comparing and analyzing of extra-factor.

  • PDF

Challenges and Design Strategies for Conversion-Based Anode Materials for Lithium- and Sodium-Ion Batteries

  • Kim, Hyunwoo;Kim, Dong In;Yoon, Won-Sub
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.32-53
    • /
    • 2022
  • Although lithium-ion batteries are currently the most reliable power supply system for various mobile applications, further improvement in energy density is still required as the need for batteries in large energy-consuming devices is rapidly growing. However, in the anode, the most widely commercialized graphite-based anode materials almost face theoretical limitations. In addition, sodium-ion batteries have been actively studied to replace expensive charge carriers with cheaper ones. Accordingly, conversion-based materials have been extensively studied as high-capacity anode materials in both lithiumion batteries and sodium-ion batteries because their theoretical capacity is twice or thrice higher than that of insertion-based materials. This review will provide a comprehensive understanding of conversion-based materials, including basic charge storage behaviors, critical drawbacks that should be overcome, and practical material design for high-performance.

Comparison of Two pMDIs in Adult Asthmatics: A Randomized Double-Blind Double-Dummy Clinical Trial

  • Nam, Tae-Hyun;Kang, Sung-Yoon;Lee, Sang Min;Kim, Tae-Bum;Lee, Sang Pyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.1
    • /
    • pp.25-36
    • /
    • 2022
  • Background: Only a few studies directly compared the therapeutic efficacy and safety of two pressurized metered-dose inhalers (pMDIs) in asthma. We analyzed the asthma treatment outcomes, safety, and patient preferences using formoterol/beclomethasone (FORM/BDP), a pMDI with extra-fine particles, compared with formoterol/budesonide (FORM/BUD), another pMDI with non-extra-fine particles. Methods: In this randomized, double-blind, double-dummy parallel group study, 40 adult asthmatics were randomized to FORM/BDP group (n=18; active FORM/BDP and placebo FORM/BUD) or FORM/BUD group (n=22; active FORM/BUD and placebo FORM/BDP). During the two visits (baseline and end of 8-week treatment), subjects were asked to answer questionnaires including asthma control test (ACT), asthma control questionnaires (ACQ), and Quality of Life Questionnaire for Adult Korean Asthmatics (QLQAKA). Lung function, compliance with inhaler, and inhaler-handling skills were also assessed. Results: Ten subjects in the FORM/BDP group and 14 in the FORM/BUD group completed follow-up visits. ACT, ACQ, QLQAKA (a primary outcome), and adverse events did not differ between two groups. We found that the increase in forced expiratory volume in 1 second/forced vital capacity and forced expiratory flow at 25% to 75% of the pulmonary volume in the FORM/BDP group was higher than in the FORM/BUD group. Regarding preference, subjects responded that the flume velocity of FORM/BDP was higher, but more adequate than that of FORM/BUD. They also answered that FORM/BDP reached the trachea and bronchus and irritated them significantly more than FORM/BUD. Conclusion: The use of pMDI with extra-fine particles may relieve small airway obstruction more than the one with non-extra-fine particles despite no significant differences in overall treatment outcomes. Some asthmatics have a misconception about the adequacy of high flume velocity of pMDIs.

Serially Concatenated Space-Time LDPC Codes for High Data Rate Wireless Communication (고속 무선 통신을 위한 직렬 연접 시공간 LDPC 부호에 관한 연구)

  • 장혜경;이문호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.335-338
    • /
    • 2002
  • For high data rate transmission over wireless fading channels, space-time trellis ceding techniques can be employed to increase the Information capacity of the communication system dramatically. In this paper, we consider the concatenated space time LDPC (Low Density Parity Check) codes. Extra ceding gains In addition to the diversity advantage is shown to be achieved for certain space-time trellis codes transmitted over quasi-static lading channels.

  • PDF

A Robust Reversible Data Hiding Scheme with Large Embedding Capacity and High Visual Quality

  • Munkbaatar, Doyoddorj;Park, Young-Ho;Rhee, Kyung-Hyune
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.7
    • /
    • pp.891-902
    • /
    • 2012
  • Reversible data hiding scheme is a form of steganography in which the secret embedding data can be retrieved from a stego image for the purpose of identification, copyright protection and making a covert channel. The reversible data hiding should satisfy that not only are the distortions due to artifacts against the cover image invisible but also it has large embedding capacity as far as possible. In this paper, we propose a robust reversible data hiding scheme by exploiting the differences between a center pixel and its neighboring pixels in each sub-block of the image to embed secret data into extra space. Moreover, our scheme enhances the embedding capacity and can recover the embedded data from the stego image without causing any perceptible distortions to the cover image. Simulation results show that our proposed scheme has lower visible distortions in the stego image and provides robustness to geometrical image manipulations, such as rotation and cropping operations.

A Study on the Introduction of Warehouse Type CY in Container Terminal

  • Kim, Hwan-Seong;Ryu, Ki-Suck;Kim, Sung-Hun;Hong, Su-Sik;Chu, Bong-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.74.4-74
    • /
    • 2001
  • In this paper, we propose a row warehouse type container yard (WTCY) which deal with the excess of port´s container capacity in 2004 instead of using the Yangsan inland container depot (ICD) in Pusan container terminals. Because the off dock container yard (ODCY) which located in Pusan port around exceeds the port´s capacity in 2004, the Yansan ICD will be used for handling an overflowed amount of containers. But there are need an amount of extra expense includes social overhead capital (SOC) to transports containers to Yangsan ICD. To overcome this problem, a WTCY which can be handled the container in each floors is proposed. The proposed WTCY can be located in container terminal ...

  • PDF

Effect of dynamic range consumption for microholographic data storage system (마이크로 홀로그래픽 시스템에서 미디어의 소진효과)

  • Kim, Do-Hyung;Min, Cheol-Ki;Cho, Jang-Hyun;Kim, Nak-Yeong;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.31-35
    • /
    • 2011
  • In microholographic data storage system (MDSS), compact recording is required to achieve high capacity.[1] When the data is recorded, neighbor monomer is also affected by reaction at the focal point.[2,3] This unintended process caused more monomer consumption and degradation of total capacity. To avoid this extra consumption of dynamic range, it is required to define the effective dynamic range for MDSS. In this paper, we experimentally investigate the relation between dynamic range consumption and micro grating formation. Dynamic range consumption was monitored by real time read-out system. Micrograting was recorded with different consumption ratio and compared by diffraction efficiency of track direction. Finally, we define suitable dynamic range for MDSS.

Analysis on the Actual Conditions of Wastewater Treatment Facilities in Chungcheongnam-do Province Industrial Complexes (충청남도 산업단지의 오·폐수처리실태 분석)

  • Lim, Bong-Su;Kim, Do-Young;Yi, Sang-Jin;Oh, Hye-Jung
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.850-862
    • /
    • 2007
  • This study was carried out to survey the actual conditions of wastewater treatment facilities to obtain basic data for the management of wastewater from industrial complexes in Chungcheongnam-do province. Wastewater production flow per site area by watersheds was $49.2m^3/km^2/d$ for Sapgyoho, $8.1m^3/km^2/d$ for Anseongcheon, $5.7m^3/km^2/d$ for Seohae, and $2.9m^3/km^2/d$ for Geumgang. Sapgyoho showed 75% of the total production flow, which was the highest value, Geumgang showed 4% of total flow, which was the lowest value. Average total extra rate as production flow/capacity flow in the wastewater treatment facilities for industrial complex is 49%. Considering by watersheds, the extra rates of Seohae, Geumgang, Anseongcheon, and Sapgyoho, are 73%, 65%, 62%, and 33% respectively. This means that the design of capacity flow in wastewater treatment facilities was too large. Effluent concentration of wastewater treatment facilities did not exceed discharge limit mostly. The removal efficiency rate for water quality item was 90% in BOD, 70% in COD, 80% in SS, 30 to 80% in TN, and 20 to 90% in TP, so the organic removal was good, but the nutrient removal was low and interval of variation was high. The removal efficiency rate of the agricultural was industrial complexes is lower than the national and local complexes. The construction cost of the wastewater treatment facilities in Chungcheongnam-do was $1,756Won\;per\;m^3$, treatment cost was $189Won\;per\;m^3$, and they were about two times and 1.2 times higher than the nation-wide cost, respectively. The treatment cost consists of 39% for man power, 21% for chemical, 16% for power, 11% for sludge treatment, and 13% for others.