Browse > Article
http://dx.doi.org/10.4046/trd.2021.0093

Comparison of Two pMDIs in Adult Asthmatics: A Randomized Double-Blind Double-Dummy Clinical Trial  

Nam, Tae-Hyun (Division of Pulmonology and Allergy, Department of Internal Medicine, Gachon University Gil Medical Center)
Kang, Sung-Yoon (Division of Pulmonology and Allergy, Department of Internal Medicine, Gachon University Gil Medical Center)
Lee, Sang Min (Division of Pulmonology and Allergy, Department of Internal Medicine, Gachon University Gil Medical Center)
Kim, Tae-Bum (Department of Allergy and Clinical Immunology, Asan Medical Center, University of Ulsan College of Medicine)
Lee, Sang Pyo (Division of Pulmonology and Allergy, Department of Internal Medicine, Gachon University Gil Medical Center)
Publication Information
Tuberculosis and Respiratory Diseases / v.85, no.1, 2022 , pp. 25-36 More about this Journal
Abstract
Background: Only a few studies directly compared the therapeutic efficacy and safety of two pressurized metered-dose inhalers (pMDIs) in asthma. We analyzed the asthma treatment outcomes, safety, and patient preferences using formoterol/beclomethasone (FORM/BDP), a pMDI with extra-fine particles, compared with formoterol/budesonide (FORM/BUD), another pMDI with non-extra-fine particles. Methods: In this randomized, double-blind, double-dummy parallel group study, 40 adult asthmatics were randomized to FORM/BDP group (n=18; active FORM/BDP and placebo FORM/BUD) or FORM/BUD group (n=22; active FORM/BUD and placebo FORM/BDP). During the two visits (baseline and end of 8-week treatment), subjects were asked to answer questionnaires including asthma control test (ACT), asthma control questionnaires (ACQ), and Quality of Life Questionnaire for Adult Korean Asthmatics (QLQAKA). Lung function, compliance with inhaler, and inhaler-handling skills were also assessed. Results: Ten subjects in the FORM/BDP group and 14 in the FORM/BUD group completed follow-up visits. ACT, ACQ, QLQAKA (a primary outcome), and adverse events did not differ between two groups. We found that the increase in forced expiratory volume in 1 second/forced vital capacity and forced expiratory flow at 25% to 75% of the pulmonary volume in the FORM/BDP group was higher than in the FORM/BUD group. Regarding preference, subjects responded that the flume velocity of FORM/BDP was higher, but more adequate than that of FORM/BUD. They also answered that FORM/BDP reached the trachea and bronchus and irritated them significantly more than FORM/BUD. Conclusion: The use of pMDI with extra-fine particles may relieve small airway obstruction more than the one with non-extra-fine particles despite no significant differences in overall treatment outcomes. Some asthmatics have a misconception about the adequacy of high flume velocity of pMDIs.
Keywords
Asthma; Metered-Dose Inhalers; Particle Size; Treatment Outcome; Preference;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Park JW, Cho YS, Lee SY, Nahm DH, Kim YK, Kim DK, et al. Multi-center study for the utilization of quality of life questionnaire for adult Korean asthmatics (QLQAKA). J Asthma Allergy Clin Immunol 2000;20:467-80.
2 Lee SM, Chang YS, Kim CW, Kim TB, Kim SH, Kwon YE, et al. Skills in handling turbuhaler, diskus, and pressurized metered-dose inhaler in Korean asthmatic patients. Allergy Asthma Immunol Res 2011;3:46-52.   DOI
3 Miller MR, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A, et al. Standardisation of spirometry. Eur Respir J 2005;26:319-38.   DOI
4 Macklem PT. The physiology of small airways. Am J Respir Crit Care Med 1998;157(5 Pt 2):S181-3.   DOI
5 Lebecque P, Kiakulanda P, Coates AL. Spirometry in the asthmatic child: is FEF25-75 a more sensitive test than FEV1/FVC? Pediatr Pulmonol 1993;16:19-22.   DOI
6 Worth H, Muir JF, Pieters WR. Comparison of hydrofluoroalkane-beclomethasone dipropionate Autohaler with budesonide Turbuhaler in asthma control. Respiration 2001;68:517-26.   DOI
7 Bunnag C, Fuangtong R, Pothirat C, Punyaratabandhu P. A comparative study of patients' preferences and sensory perceptions of three forms of inhalers among Thai asthma and COPD patients. Asian Pac J Allergy Immunol 2007;25:99-109.
8 Papi A, Paggiaro PL, Nicolini G, Vignola AM, Fabbri LM; Inhaled Combination Asthma Treatment versus SYmbicort (ICAT SY) Study Group. Beclomethasone/formoterol versus budesonide/formoterol combination therapy in asthma. Eur Respir J 2007;29:682-9.   DOI
9 Leach C, Colice GL, Luskin A. Particle size of inhaled corticosteroids: does it matter? J Allergy Clin Immunol 2009;124(6 Suppl):S88-93.   DOI
10 Papi A, Mansur AH, Pertseva T, Kaiser K, McIver T, Grothe B, et al. Long-term fluticasone propionate/formoterol fumarate combination therapy is associated with a low incidence of severe asthma exacerbations. J Aerosol Med Pulm Drug Deliv 2016;29:346-61.   DOI
11 Kwon HS, Lee SH, Yang MS, Lee SM, Kim SH, Kim DI, et al. Correlation between the Korean version of Asthma Control Test and health-related quality of life in adult asthmatics. J Korean Med Sci 2008;23:621-7.   DOI
12 Magnussen H, Fyrnys B, Greguletz R. Genuair((R))/Pressair((R)) inhaler in COPD: the patient perspective. COPD 2019;16:196-205.   DOI
13 Benfante A, Basile M, Battaglia S, Spatafora M, Scichilone N. Use of ICS/LABA (extra-fine and non-extra-fine) in elderly asthmatics. Ther Clin Risk Manag 2016;12:1553-62.   DOI
14 Nicolini G, Scichilone N, Bizzi A, Papi A, Fabbri LM. Beclomethasone/formoterol fixed combination for the management of asthma: patient considerations. Ther Clin Risk Manag 2008;4:855-64.   DOI
15 Hawken N, Torvinen S, Neine ME, Amri I, Toumi M, Aballea S, et al. Patient preferences for dry powder inhaler attributes in asthma and chronic obstructive pulmonary disease in France: a discrete choice experiment. BMC Pulm Med 2017;17:99.   DOI
16 von Schantz S, Katajavuori N, Antikainen O, Juppo A. Evaluation of dry powder inhalers with a focus on ease of use and user preference in inhaler-naive individuals. Int J Pharm 2016;509:50-8.   DOI
17 Busse WW, Brazinsky S, Jacobson K, Stricker W, Schmitt K, Vanden Burgt J, et al. Efficacy response of inhaled beclomethasone dipropionate in asthma is proportional to dose and is improved by formulation with a new propellant. J Allergy Clin Immunol 1999;104:1215-22.   DOI
18 GBD Chronic Respiratory Disease Collaborators. Prevalence and attributable health burden of chronic respiratory diseases, 1990-2017: a systematic analysis for the Global Burden of Disease Study 2017. Lancet Respir Med 2020;8:585-96.   DOI
19 National Institute of Health, National Heart Lung and Blood Institute. A Global Initiative for Asthma: global strategy for asthma management and prevention. NHLBI/WHO workshop report no. 02-3659 January 1995, updated 2020. Bethesda: National Heart Lung and Blood Institute; 2020.
20 Rohatagi S, Appajosyula S, Derendorf H, Szefler S, Nave R, Zech K, et al. Risk-benefit value of inhaled glucocorticoids: a pharmacokinetic/pharmacodynamic perspective. J Clin Pharmacol 2004;44:37-47.   DOI
21 Hauber H, Taha R, Bergeron C, Migounov V, Hamid Q, Olivenstein R. Effects of hydrofluoroalkane and dry powder-formulated corticosteroids on sputum inflammatory markers in asthmatic patients. Can Respir J 2006;13:73-8.   DOI
22 Papi A, Paggiaro P, Nicolini G, Vignola AM, Fabbri LM; ICAT SE Study Group. Beclomethasone/formoterol vs fluticasone/salmeterol inhaled combination in moderate to severe asthma. Allergy 2007;62:1182-8.   DOI
23 Usmani OS, Biddiscombe MF, Barnes PJ. Regional lung deposition and bronchodilator response as a function of beta2-agonist particle size. Am J Respir Crit Care Med 2005;172:1497-504.   DOI
24 Lavorini F, Corrigan CJ, Barnes PJ, Dekhuijzen PR, Levy ML, Pedersen S, et al. Retail sales of inhalation devices in European countries: so much for a global policy. Respir Med 2011;105:1099-103.   DOI
25 Yun Kirby S, Zhu CQ, Kerwin EM, Stanford RH, Georges G. A preference study of two placebo dry powder inhalers in adults with COPD: ELLIPTA(R) Dry Powder Inhaler (DPI) versus DISKUS(R) DPI. COPD 2016;13:167-75.   DOI
26 Giner J, Villarnovo Cerrillo M, Aboin Sierra J, Casas Herrero L, Patino O, Plaza V. Assessment of inhalation errors, training time and patient preference for DuoResp(R) Spiromax(R) and Symbicort(R) Turbuhaler(R) in patients with asthma and COPD. Eur Clin Respir J 2020;8:1833411.
27 Tonnel AB, Bons J, Legendre M, Prud'Homme A, Bugnas B, Evano-Celli I, et al. Clinical efficacy and safety of fluticasone propionate 250 microg twice daily administered via a HFA 134a pressurized metered dose inhaler to patients with mild to moderate asthma. French study group. Respir Med 2000;94 Suppl B:S29-34.
28 Kim MK, Park HS, Park CS, Min SJ, Albers FC, Yancey SW, et al. Efficacy and safety of mepolizumab in Korean patients with severe eosinophilic asthma from the DREAM and MENSA studies. Korean J Intern Med 2021;36:362-70.   DOI
29 Kozma CM, Slaton TL, Monz BU, Hodder R, Reese PR. Development and validation of a patient satisfaction and preference questionnaire for inhalation devices. Treat Respir Med 2005;4:41-52.   DOI
30 van den Berge M, Ten Hacken NH, Cohen J, Douma WR, Postma DS. Small airway disease in asthma and COPD: clinical implications. Chest 2011;139:412-23.   DOI
31 Foster JM, Aucott L, van der Werf RH, van der Meijden MJ, Schraa G, Postma DS, et al. Higher patient perceived side effects related to higher daily doses of inhaled corticosteroids in the community: a cross-sectional analysis. Respir Med 2006;100:1318-36.   DOI
32 Svedsater H, Dale P, Garrill K, Walker R, Woepse MW. Qualitative assessment of attributes and ease of use of the ELLIPTA dry powder inhaler for delivery of maintenance therapy for asthma and COPD. BMC Pulm Med 2013;13:72.   DOI
33 Newman S, Pitcairn G, Steed K, Harrison A, Nagel J. Deposition of fenoterol from pressurized metered dose inhalers containing hydrofluoroalkanes. J Allergy Clin Immunol 1999;104:S253-7.   DOI
34 Ding B, Small M, Scheffel G, Holmgren U. Maintenance inhaler preference, attribute importance, and satisfaction in prescribing physicians and patients with asthma, COPD, or asthma-COPD overlap syndrome consulting for routine care. Int J Chron Obstruct Pulmon Dis 2018;13:927-36.   DOI
35 Sandler N, Hollander J, Langstrom D, Santtila P, Saukkonen A, Torvinen S. Evaluation of inhaler handling-errors, inhaler perception and preference with Spiromax, Easyhaler and Turbuhaler devices among healthy Finnish volunteers: a single site, single visit crossover study (Finhaler). BMJ Open Respir Res 2016;3:e000119.   DOI