• Title/Summary/Keyword: External Rotation

Search Result 562, Processing Time 0.024 seconds

An Experimental Study for Reinforcement Effect of Adhesive Stiffeners Depending on the Aspect Ratio of Masonry Wall (조적벽체의 형상비에 따른 접착형 보강재의 보강효과에 관한 실험적 연구)

  • Park, Byung-Tae;Kwon, Ki-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.13-20
    • /
    • 2017
  • Unreinforced masonry buildings are vulnerable to lateral forces, such as earthquakes, owing to the nature of the building materials, yet numerous masonry buildings remain in South Korea. Since the majority of the existing masonry buildings were constructed more than 20 years ago, it is necessary to develop economical reinforcement methods for disaster reduction. In this study, external reinforcement of masonry walls using adhesive stiffeners was proposed as a reinforcement method for such age-old masonry buildings. Six specimens were fabricated with different aspect ratios (L/H = 1.0, 1.3, and 2.0) and used in static load tests to verify the reinforcement effect. The experimental results showed that the masonry walls before and after reinforcement were ruptured by rigid body rotation and slip. In addition, the maximum strength, maximum displacement, and dissipated energy of the walls were shown to increase after applying the adhesive stiffeners, thereby verifying the excellent reinforcement effect. Furthermore, an adhesive stiffener design for unreinforced masonry walls was proposed based on the increased shear strength achieved by using conventional glass fibers. The proposed design can be used as a basis for the application of adhesive stiffeners for unreinforced masonry walls.

Influence of Tungsten Carbide/Carbon Coating on the Preload and Tightening Torque of Implant Abutment Screws (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중 및 조임회전각에 미치는 영향)

  • Shin, Hyon-Mo;Cho, Wook;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.53-59
    • /
    • 2009
  • The purpose of this study was to clarify the clinical efficiency of tungsten carbide/carbon coating on obtaining optimal preload of abutment screw compared with non-coated screw in external-hex implant system. In the present work, rotational value and the compressive force between abutment and fixture of abutment screws without coating and with coating tightened to 30Ncm were measured. Mean compressive force of coated screw was 504.6N. Then uncoated screw was tightened to clamping the abutment and the implant to 504.6N, and the tightening torque value and the rotational value was recorded. The following conclusions were drawn within the limitation of this study. Compressive force of coated screw was higher than that of uncoated screw after tightening at 30Ncm. The tightening torque that was nedeed to clamping the uncoated screw equal to coated screw tightened to 30Ncm was 55.6Ncm. In case of equal compressive force, there was no significant difference in rotation value between coated and uncoated screw.

Precise Orbital and Geodetic Parameter Estimation using SLR Observations for ILRS AAC

  • Kim, Young-Rok;Park, Eunseo;Oh, Hyungjik Jay;Park, Sang-Young;Lim, Hyung-Chul;Park, Chandeok
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.269-277
    • /
    • 2013
  • In this study, we present results of precise orbital geodetic parameter estimation using satellite laser ranging (SLR) observations for the International Laser Ranging Service (ILRS) associate analysis center (AAC). Using normal point observations of LAGEOS-1, LAGEOS-2, ETALON-1, and ETALON-2 in SLR consolidated laser ranging data format, the NASA/GSFC GEODYN II and SOLVE software programs were utilized for precise orbit determination (POD) and finding solutions of a terrestrial reference frame (TRF) and Earth orientation parameters (EOPs). For POD, a weekly-based orbit determination strategy was employed to process SLR observations taken from 20 weeks in 2013. For solutions of TRF and EOPs, loosely constrained scheme was used to integrate POD results of four geodetic SLR satellites. The coordinates of 11 ILRS core sites were determined and daily polar motion and polar motion rates were estimated. The root mean square (RMS) value of post-fit residuals was used for orbit quality assessment, and both the stability of TRF and the precision of EOPs by external comparison were analyzed for verification of our solutions. Results of post-fit residuals show that the RMS of the orbits of LAGEOS-1 and LAGEOS-2 are 1.20 and 1.12 cm, and those of ETALON-1 and ETALON-2 are 1.02 and 1.11 cm, respectively. The stability analysis of TRF shows that the mean value of 3D stability of the coordinates of 11 ILRS core sites is 7.0 mm. An external comparison, with respect to International Earth rotation and Reference systems Service (IERS) 08 C04 results, shows that standard deviations of polar motion $X_P$ and $Y_P$ are 0.754 milliarcseconds (mas) and 0.576 mas, respectively. Our results of precise orbital and geodetic parameter estimation are reasonable and help advance research at ILRS AAC.

Usefulness of External Monitoring Flap in the Buried Jejunal Free Flap (유리 공장 피판술 후 외부 감시 피판의 유용성)

  • Kim, Baek Kyu;Chang, Hak;Minn, Kyung Won;Hong, Joon Pio;Koh, Kyung Suck
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.432-435
    • /
    • 2007
  • Purpose: The jejunal free flap has the shorter ischemic time than other flap and requires a laparotomy to harvest it. As the evaluation of the perfusion the buried flap is very important, the perfusion of the buried jejunal free flap requires monitoring for its salvage. We tried to improve the monitoring flap method in the jejunal free flap and examined its usefulness. Methods: From March 2002 to March 2006, the monitoring flap method was applied to 4 cases in 8 jejunal free flaps for the pharyngeal and cervical esophageal reconstructions. The distal part of the jejunal flap was exposed without suture fixation through cervical wound for monitoring its perfusion. The status of perfusion was judged by the color change of jejunal mucosa and mesentery. If necessary, pin prick test was performed. Doppler sonography was applied to mesenteric pedicle of the monitoring flap in case of suspicious abnormal circulation. Results: The monitoring flap shows no change in 3 cases, but the congestion happened in one case at the 12 hours after the operation. This congestion was caused by the twisting or kinking of the mesenteric pedicle of the monitoring flap. So, we fixed up the monitoring flap close to adjacent cervical skin for prevention of rotation. Finally, the main part of transferred jejunal flap was intact. Conclusion: The success of a jejunal free flap depends on close postoperative monitoring and early detection of vascular compromise. So, various monitoring methods have been tried, for instance, direct visualization using a fiberoptic pharyngoscope, through a Silastic window placed in the neck flap, or external surface monitoring with an Doppler sonography, use of a buried monitoring probe. But, all of the above have their own shortcomings of simplicity, non-invasiveness, reliability and etc. In our experience, monitoring flap can be a accurate and reliable method.

Simulating tentacle Creature with External Magnetism for Animatronics (외부 자력을 이용한 촉수 생명체 애니매트로닉스 시뮬레이션)

  • Ye Yeong Kim;Do Hee Kim;Ju Ran Kim;Na Hyun Oh;Myung Geol Choi
    • Journal of the Korea Computer Graphics Society
    • /
    • v.29 no.5
    • /
    • pp.1-9
    • /
    • 2023
  • The control technology of animatronics is an interesting topic explored in various fields, including engineering, medicine, and art, with ongoing research efforts. The conventional method for controlling the movement of animatronics is to use electric motors installed inside the body. However, this method is difficult to apply when expressing a narrow space inside the body. In this study, a method of using external forces instead of installing mechanical devices inside the body was proposed to control the movement of a thin and long tentacle organism. Specifically, in this study, the joint body of animatronics was made of magnetic metal material so that it could be affected by the force of an externally installed electromagnet. The strength of the electromagnet was controlled by a PID controller to enable real-time control of the position of the animatronics body. In addition, the magnet was made to rotate, and the speed of rotation was changed to create various movements. Through virtual environment simulations, our experiments demonstrate the superiority of the proposed method, showcasing real-time control by users and the creation of animations in various styles.

Influence of Anticipation on Landing Patterns during Side-Cutting Maneuver in Female Collegiate Soccer Players

  • Park, Eun-Jung;Lee, Jung-Ho;Ryue, Jae-Jin;Sohn, Ji-Hoon;Lee, Ki-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.391-395
    • /
    • 2011
  • To investigate the anticipatory effect on landing patterns during side-cutting maneuver, thirteen healthy female elite college soccer players participated in this study. Three-dimensional knee kinematics, effective mass and correlation between both these were measured and analyzed using a motion analysis and force plates. Each testing session included anticipated tasks, $45^{\circ}$ side-cutting tasks (AC), followed by a set of unexpected side-cutting (UC) in a random order. Knee flexion/extension, valgus/varus and internal/external rotation angles and effect mass were compared by using paired t-test. Also, correlation analysis was performed to identify the relationship between knee angles and effective mass. Effective mass during UC was greater than that during AC. Effective mass and maximum knee flexion angle were positively correlated during AC and not during UC. Based on the relationship between effective mass and knee flexion angle in AC, shock absorption can be controlled by knee joint flexion in pre-predicted movement condition. However, effective mass can not be controlled by knee flexion in UC condition. The unexpected load affects were more irregular on the knee joint, which may be one of the injury mechanisms of anterior cruciate ligament (ACL) in female soccer players.

The Shoulder Pain after Stroke and the relationship with Motor Function, and Quality of Life (뇌졸중 환자의 견관절 통증과 운동 기능 및 삶의 만족도와의 관계)

  • Lee, Dong-Jin;An, Seung-Heon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.3
    • /
    • pp.257-266
    • /
    • 2011
  • Purpose : To assess the relationship between post-stroke shoulder pain, motor function, and pain-related quality of life(QOL) Methods : Volunteer sample of 62 chronic stroke survivors with post-stroke shoulder pain and glenohumeral subluxation. The patients answered the question in shoulder pain with the Brief Pain Inventory question 12 (BP1-12), Pain-related Quality of life(BPI-23). Therapists measured the performance of combined upper-limb movement including the hand-behind-neck(HBN), hand-behind-beck(HBB) maneuver, added passive pain-free shoulder external rotation range of motion, and Modified Ashworth Scale(MAS) score of the elbow flexors. Physical performance assessments were used to measure basic activity daily living(Modified Barthel Index-self care, MBI-S/C), motor function of upper limb(Fugl-Meyer Upper/Lower Extremity, FM-U/E). Results : Stepwise regression analyses indicated that post-stroke shoulder pain is associated with the BPI 23, but not with the FM-U/E, MBI-S/C. Thus, the presence of shoulder pain is more important predicting pain-related QOL than its degree in predicting motor function of upper limb and basic activity daily living. Conclusion : Post-stroke shoulder pain was associated with reduced quality of life related to pain. The pain was not associated with the motor function of upper limb and basic activity daily living. The result imply that management of shoulder pain & anatomical position of shoulder joint after stroke should be emphasized. This provides a further incentive to develop effective rehabilitation prevention and treatment strategies for post-stroke shoulder pain.

The Comparative Study of Effectiveness of Cotreatment with $Samgieum-gagam$, Acupuncture and Sweet Bee Venom Acupuncture on Post-stroke Shoulder Pain (삼기음가감방과 봉약침, 체침의 병행치료가 뇌졸중 후 견관절 통증에 미치는 효과 비교연구)

  • Cho, Song-Hyun;Cho, Hong-Seok;Lee, Kyung-Yun;Yun, Suk-Hoon;Jung, Woo-Suk;Kim, Sang-Ho
    • Journal of Acupuncture Research
    • /
    • v.29 no.2
    • /
    • pp.15-27
    • /
    • 2012
  • Objectives : The purpose of this study is to evaluate the effect of cotreatment with $Samgieum-gagam$, acupuncture and sweet bee venom acupuncture on post-stroke shoulder pain. Methods : The subjects in this study were 43 patients with post-stroke hemiplegic shoulder pain. These patients were randomly divided into four groups : the group treated with acupuncture, the group cotreated with acupuncture and sweet bee venom acupuncture, the group cotreated with acupuncture and $Samgieum-gagam$, the group cotreated with acupuncture, sweet bee venom acupuncture and Samgieumgagam, They were treated for 4 weeks, and the effectiveness was assessed by visual analogue scale(VAS), Fugl-Meyer motor assessment(FMMA), painless passive ROM of shoulder external rotation(PROM), Modified Ashworth sacle(MAS) and Satisfaction. Results : All groups showed significant change in VAS, FMMA and PROM. The group cotreated with acupuncture, sweet bee venom acupuncture and $Samgieum-gagam$ showed more effectiveness in VAS and FMMA than the group treated with acupuncture. There was no significant difference in MAS among groups. Conclusions : This study suggests that cotreatment with $Samgieum-gagam$, acupuncture and sweet bee venom acupuncture is more effective than acupuncture treatment only on post-stroke shoulder pain. Further study based on many other combination methods, larger population, and long term follow-up is needed to confirm this suggestion.

Clinical and Radiological Results of Reverse Total Shoulder Arthroplasty Using a 25-mm Glenoid Baseplate

  • Lee, Ji Min;Kim, In Bo;Jung, Dong Wook
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.4
    • /
    • pp.242-247
    • /
    • 2015
  • Background: The size of the baseplate used in reverse total shoulder arthroplasty (RTSA) tends to be larger than the average size of the glenoid in the Korean population. The mismatch between the sizes of the baseplate and the patient's glenoid may result in improper fixation of the glenoid baseplate. This in turn may lead to the premature loosening of the glenoid component. Thus, we evaluated the short-term results of using a 25-mm baseplate in RTSA. Methods: Seventeen patients with cuff tear arthropathy underwent RTSA with a 25-mm baseplate. The mean age of the patients was 70.1 years, and the mean follow-up period was 14.0 months. We evaluated clinical outcomes preoperatively and postoperatively: the range of shoulder motion, the American Shoulder and Elbow Surgeons (ASES) score, and the Korean Shoulder Society (KSS) score. Results: We found that the mean ASES score and KSS improved from 35.0 to 74.4 (p<0.001) and from 46.9 to 71.8 (p<0.001) with RTSA. The mean forward elevation and abduction, external rotation also improved from $78.6^{\circ}$ to $134.3^{\circ}$ (p<0.05) and from $66.6^{\circ}$ to $125.0^{\circ}$ (p<0.05), from $20.2^{\circ}$ to $28.4^{\circ}$ (p=0.43). Postoperative complications were seen in 12% of patients, but neither the loosening of the glenoid baseplate nor inferior scapular notching were observed. Conclusions: In sum, the results of using a 25-mm baseplate in RTSA were similar to those of previous reports. Even though the outcomes are those of a short-term follow-up, neither the loosening of the glenoid baseplate nor the scapular notching were observed.

Effect of Scolopendrid Pharmacupuncture Therapy on Frozen Shoulder Patients (동결견(凍結肩) 환자의 오공약침(蜈蚣藥鍼) 치료에 대한 임상적 고찰)

  • Kim, Do-Ho;Kim, Hyun-Wook;Lee, Geon-Hui;Lee, Geon-Mok
    • Journal of Acupuncture Research
    • /
    • v.26 no.1
    • /
    • pp.1-14
    • /
    • 2009
  • Objectives : The purpose of this research was to study the effect of Scolopendrid Pharmacopuncture on frozen shoulder patients. Methods : All of the 46 frozen shoulder patients who visited the department of Acupuncture & Moxibustion in Wonkwang Sanbon Medical Center from 1st March 2007 to 30th August 2008 had taken either the Scolopendrid Pharmacopuncture therapy or acupuncture therapy 10 times. There are 23 patients in each group. We evaluated the improvement of their shoulder pain and disability using the Visual Analog Scale(VAS), Shoulder Pain And Diability Index(SPADI), Range of Motion(ROM), and the Apley Scratch test at their first and last visit. Then we analyzed and compared the improvement shown by the two groups. Results : 1. Measures on all tests for the acupuncture group showed statistically significant improvement. 2. Measures on all tests for Scolopendrid Pharmacopuncture showed statistically significant improvement. 3. The Scolopendrid Pharmacopuncture group's VAS and ROM(external, internal rotation) showed statistically significant difference compared with those of the acupuncture group. SPADI, ROM(flexion, extension, abduction, adduction) and Apley scratch test had no statistically significant difference between the two groups. Conclusions : The above results show that Scolopendrid Pharmacopuncture therapy can be used as an effective treatment for reducing frozen shoulder pain.

  • PDF