Browse > Article

Usefulness of External Monitoring Flap in the Buried Jejunal Free Flap  

Kim, Baek Kyu (Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine)
Chang, Hak (Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine)
Minn, Kyung Won (Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine)
Hong, Joon Pio (Department of Plastic Surgery, University of Ulsan, College of Medicine)
Koh, Kyung Suck (Department of Plastic Surgery, University of Ulsan, College of Medicine)
Publication Information
Archives of Plastic Surgery / v.34, no.4, 2007 , pp. 432-435 More about this Journal
Abstract
Purpose: The jejunal free flap has the shorter ischemic time than other flap and requires a laparotomy to harvest it. As the evaluation of the perfusion the buried flap is very important, the perfusion of the buried jejunal free flap requires monitoring for its salvage. We tried to improve the monitoring flap method in the jejunal free flap and examined its usefulness. Methods: From March 2002 to March 2006, the monitoring flap method was applied to 4 cases in 8 jejunal free flaps for the pharyngeal and cervical esophageal reconstructions. The distal part of the jejunal flap was exposed without suture fixation through cervical wound for monitoring its perfusion. The status of perfusion was judged by the color change of jejunal mucosa and mesentery. If necessary, pin prick test was performed. Doppler sonography was applied to mesenteric pedicle of the monitoring flap in case of suspicious abnormal circulation. Results: The monitoring flap shows no change in 3 cases, but the congestion happened in one case at the 12 hours after the operation. This congestion was caused by the twisting or kinking of the mesenteric pedicle of the monitoring flap. So, we fixed up the monitoring flap close to adjacent cervical skin for prevention of rotation. Finally, the main part of transferred jejunal flap was intact. Conclusion: The success of a jejunal free flap depends on close postoperative monitoring and early detection of vascular compromise. So, various monitoring methods have been tried, for instance, direct visualization using a fiberoptic pharyngoscope, through a Silastic window placed in the neck flap, or external surface monitoring with an Doppler sonography, use of a buried monitoring probe. But, all of the above have their own shortcomings of simplicity, non-invasiveness, reliability and etc. In our experience, monitoring flap can be a accurate and reliable method.
Keywords
Jejunal free flap; Monitoring flap;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Ahn HC, Han YS, Lee SK, Lee JD: Oropharyngoesophagus reconstruction with jejunal free transfer. J Korean Soc Plast Reconstr Surg 16: 523, 1989
2 Park BW, Park WK, Yang KM: Reconstruction of esophagus by free jejunal flap. J Korean Soc Plast Reconstr Surg 22: 303, 1995
3 Khouri RK: Avoiding free flap failure. Clin Plast Surg 19: 773, 1992
4 Bafitis H, Stallings JO, Ban J: A reliable method for monitoring the microvascular patency of free jejunal transfers in reconstructing the pharynx and cervical esophagus. Plast Reconstr Surg 83: 896, 1989   DOI   ScienceOn
5 Hester TR, McConnel FM, Nahai F, Jurkiewicz MJ, Brown RG: Reconstruction of cervical esophagus, hypopharynx and oral cavity using free jejunal transfer. Am J Surg 140: 487, 1980   DOI   ScienceOn
6 Hallock GG, Koch TJ: External monitoring of vascularized jejunum transfers using laser Doppler flowmetry. Ann Plast Surg 24: 213, 1990   DOI
7 Bradford CR, Esclamado RM, Carroll WR: Monitoring of revascularized jejunal autograft. Arch Otolaryngol Head Neck Surg 118: 1042, 1992   DOI   ScienceOn
8 Cinton MS, Sepka RS, Bristol D, Pederson WC Barwick WJ, Serafin D, Klitzman B: Establishment of normal range of laser Doppler blood flow in autologous tissue transplants. Plast Reconstr Surg 87: 299, 1991   DOI   ScienceOn
9 Cho BC Shin DP, Byun JS, Park JW, Baik BS: Monitoring flap for buried free tissue transfer: its importance and reliability. Plast Reconstr Surg 110: 1249, 2002   DOI   ScienceOn
10 Katsaros J, Banis JC, Acland RD, Tan E: Monitoring free vascularised jejunum grafts. Br J Plast Surg 38: 220, 1985   DOI   ScienceOn