• 제목/요약/키워드: Exterior Environment

검색결과 307건 처리시간 0.028초

FE-BEM 및 SEA 해석 기법을 활용한 샌드위치 복합재 구조물의 전 주파수 대역 음향 해석 (Full-Frequency Band Acoustic Analysis of Sandwich Composite Structure Using FE-BEM and SEA Method)

  • 이대은;이윤규;김홍일;김재영
    • 한국군사과학기술학회지
    • /
    • 제21권4호
    • /
    • pp.422-428
    • /
    • 2018
  • Increase in use of lightweight structures, coupled with the increased acoustic loads resulting from larger and longer range guided missiles, has made missile more susceptible to failures caused by acoustic loads. Thus, accurate prediction of acoustic environment and the response is becoming ever more important for mission success. In this paper, the acoustic response of a sandwich composite skin structure to diffuse acoustic excitation is predicted over a broad frequency range. For the low frequency acoustic analysis, coupled FE-BEM method is used where the structure is modeled using FEM and the interior and exterior fluid is modeled using BEM. For the high frequency region, statistical energy analysis is applied. The predicted acoustic level inside the structure is compared with the result from acoustic test conducted in reverberation chamber, which shows very good agreement.

스테인리스강 열교환기의 틈부식 방지에 관한 연구 (Study on the Prevention of Crevice Corrosion for a Stainless Steel Heat Exchanger)

  • 임우조;윤병두
    • 수산해양교육연구
    • /
    • 제17권1호
    • /
    • pp.106-114
    • /
    • 2005
  • This paper is a study on the prevention of crevice corrosion for a stainless steel heat exchanger in various pH solutions and with Cl ion concentrations. The electrochemical polarization test and crevice corrosion test of STS 304 for a heat exchanger were carried out. The crevice corrosion aspect, a passive behavior, crevice corrosion behavior, and corrosion protection characteristics of STS 304 using Al-alloy and Mg-alloy galvanic anode were considered. The main results are as follows: 1. The crevice corrosion of STS 304 occurs in the crevice and this corrosion increases pitting according to depth direction. On the other hand, the exterior crevice becomes passive. 2. With changing from a neutral to acid environment and increasing Cl ion concentration, the pitting potential of STS 304 lowers, and thus the crevice corrosion of STS 304 is sensitive. 3. The cathodic protection potential of STS 304 in the crevice is cathodically polarized by increasing Cl ion concentration. Therefore, an Al-alloy galvanic anode is more suitable than a Mg-alloy galvanic anode to protect the crevice corrosion of STS 304.

선형침투시스템의 공동주택 외부공간 적용 방안 연구 (A case study about exterior space design of apartments using Linear infiltration system)

  • 문수영;김현수;장대희;이건호
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.9-15
    • /
    • 2007
  • As environmental problems and water-shortage phenomenon become a global issue, many states look for the effective method to use water resources. So, decentralized rainwater management is recognized as a new water management system that rainwater can be infiltrated and used on-site. But it is little difficult to build a park, lake, and forest for evaporating rainwater in city because the land price of city is very high. In order to build an excellent infiltration system for a dwelling and a park in Korea, KICT has developed Linear infiltration system. This infiltration system is consist of first flush treatment, storage and infiltration, overflow control system. These elements are connected closely and working as a combined system. A storm sewer can be changed by the linear infiltration system. This study is to show real application idea about Linear infiltration system with improving some detail in apartments. For this purpose, we devide application idea into the artificial ground and the natural ground and each ground type, suggest a method to cooperate with the other landscape and linear infiltration system. Through this study, we came to recognize a recognition difference of an expert and a commoner about decentralized rainwater management.

아트리움의 수직온도 분포해석 프로그램의 개발에 관한 연구 (A study on the Development of Vertical Air Temperature Distribution Model in Atrium)

  • 김용인;조균형;김광우
    • 태양에너지
    • /
    • 제17권3호
    • /
    • pp.3-11
    • /
    • 1997
  • Recently the construction of atrium buildings has increased but along with it many problems in thermal environment have arised. since the exterior wall of glass, indoor temperature is greatly influenced by weather conditions and since the space volume is very large, the vertical air temperature is not uniform. So, in this study, a Vertical Temperature Distribution Model was developed to predict the vertical air temperature of an atrium and evaluate the effects of the design parameters on the air temperature distribution of an atrium. To consider the characteristics of the vertical air temperature distribution in an atrium, the Satosh Togari's Macroscopic Model was used basically for the calculation of the vertical air temperature distribution in large space and the solar radiation analysis model and natural ventilation analysis model in atrium. And to calculate the unsteady-state inside wall surface temperature(boundary condition), the finite difference method was used. For the verification of the developed temperature distribution program, numerical evaluation of air flow by the ${\kappa}-{\varepsilon}$ turbulence model and in-situ test was conducted in parallel. The results of this study, the developed temperature distribution program was seen to predict the thermal condition of the atrium very accurately.

  • PDF

고속철도 차량의 스커트 장착에 의한 실내.외 소음 영향 분석 (The Noise Effect of a Skirt on Rolling-stock)

  • 김태민;김정태;김정수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.499-504
    • /
    • 2012
  • The high-speed train enjoys widespread acceptance as environment-friendly means of medium- to long-distance transportation. The pursuit of higher speed and lighter weight in railroad vehicles has engendered higher noise level. In particular, the environmental noise places many restrictions in the operation of high-speed railroad vehicles. This research investigates the effect of installing a skirt onto a high-speed train bogie with the top speed of 400 km/hr and using High Speed EMU for the purpose of reducing the environmental noise. In order to analyze the effect of the interior noise and environmental noise due to installation of the skirt, sound level is calculated using the Ray method and Statical Energy Analysis method. The numerical calculation predicts a reduction of approximately 2 dB in the environmental noise level, but at the cost of increase of approximately 2.5 dB in the interior noise level of the vehicle.

  • PDF

실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석 (Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model)

  • 백승헌;김정태
    • KIEAE Journal
    • /
    • 제6권4호
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

신한옥 주거 만족도 실태조사 연구 - 전라남도를 중심으로 - (A Study on the Actual Conditions and Responses of New Han-ok Inhabitants through Questionnaire - Focused in Jeonnam Province -)

  • 송민정;장현충;이태강;이주엽;김선우
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.3-12
    • /
    • 2013
  • Recently, New Han-ok is in prevail because it has many good qualities as a dwelling. But the New Han-ok dwellers' needs and satisfaction ratio on their houses are not investigated yet. So, surveys on satisfaction ratio for New Han-ok were carried out to know New Han-ok's existing conditions and inhabitant's responses on New Han-ok dwellings. Followings are results. 1) Dwellers response that it is cool in summer and it is cold in winter. So, design and construction method against cold is needed for New Han-ok. 2) Window is the most picking element of New Han-ok for house improvement. 3) Window opening is main control method for cooling in summer. Warming sources in winter are various such as electricity, gas, oil, wood, etc. 4) PVC window structure and glasses were used for New Han-ok's window system as well as wooden window structure and Han-gi. 5) Interviewees are generally satisfied with New Han-ok's exterior view and inner spaces. Almost no humidifier is used. These results could be used for improvement of Han-ok and basic material for New Han-ok design.

혼합형 채광조절장치가 실내공간의 주광조도분포에 미치는 영향에 관한 Mockup 실험평가 (Light Factor Performance of a Room with Light Guide and Blind Systems by Mockup Experiments)

  • 신화영;김정태
    • KIEAE Journal
    • /
    • 제7권1호
    • /
    • pp.23-31
    • /
    • 2007
  • This study aims to evaluate the illuminance performance of sloped light guide with automated venetian blind systems. For the purpose, a mock-up model was constructed as a prototype of Korean office building with $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and south facing side-window mounted between the clerestory window($2.0m^2$) and the view window($5.6m^2$). The light guide of 1.28m deepth and $29^{\circ}$ tilted angle, is covered with 0.6mm galvanized steel sheet and 97% reflective film. To protect the room from low solar angle, a blind systems, 0.15m deepth and $30^{\circ}$ automated slat angle was installed. To assess illuminance performance, the totally 37 measuring points for illuminance were monitored. For the detailed analysis, photometric sensors were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point) respectively. The performance was measured under clear sky and is monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons of light factor and uniformity are discussed.

소규모수도시설의 보안시설 설치지침 개발 (Development of Guidelines for Physical Security Systems of Small-scale Water Supplies)

  • 김영일;이상진;이두진;이원태
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.723-730
    • /
    • 2013
  • Due to the event of hazardous chemical injection into a water storage tank in Hongseong, Chungcheongnam-do in 2012, the Korean Ministry of Environment has revised the enforcement rules of the Water Supply and Waterworks Installation Act to install surveillance equipments such as closed-circuit television(CCTV). However, the enforcement rules still do not provide concrete provision for installation of physical security equipments. Thus we studied vulnerability of small-scale water supplies in Korea and developed guidelines for the physical security system of the facilities. The guidelines include selection and recommendation of the physical security approaches and measures to detect, delay and response to the presence of an intruder in small-scale water supplies. The security features include protection utilities(e.g., fencing and fence topping), exterior intrusion detectors and alarms, locks and padlocks, surveillance utilities(e.g., CCTV), and others.

전통주택의 차음성능 평가에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses)

  • 김선우;이태강;김형렬;김항;최은석
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.141-148
    • /
    • 2006
  • Korean traditional houses have been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various Passive system of using natural materials, considering micro climate, building lay out, and these system are much natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed the acoustical characteristics of Korean traditional houses varied with lay out and floor plan to reflect the way of control for environmental condition. The reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen are measured in each houses. As a result, the reverberation time of Korean traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building. These above results show that our traditional house are much more emphasized seeking visual privacy of rooms than aural privacy.