• Title/Summary/Keyword: Exposure Dose(mAs)

Search Result 613, Processing Time 0.029 seconds

Effects of Exposure Dose Reduction by Optimization of Automatic Exposure Control Factors in Digital Radiographic Examination of Paranasal Sinus (부비동 디지털 엑스선검사에서 자동노출제어 조절인자의 최적화를 통한 조사선량 감소 효과)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.173-181
    • /
    • 2021
  • The purpose of this study was to reduce dose while maintaining image quality during digital radiographic examination of paranasal sinus by using the automatic exposure control (AEC) system. The tube voltage was set as six stages that increased by about 10 kVp to 70 kVp, 81 kVp, 90 kVp, 102 kVp, 109 kVp and 117 kVp. And then the AEC system conditions were consisted of 9 setting environments, that change mode of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). We measured automatically exposed tube current (mAs) under 54 conditions with combined these, and assessed SNR and PSNR through the acquired images. In addition, four radiologists performed a qualitative assessment of the acquired images for each combination on a five-point scale of the Likert. As a result, the lowest dose and the highest values of SNR and PSNR in images with a qualitative assessment more than 4 point were the AEC control factors of 90 kVp, S800, D2.5. We applied this condition to the clinical trial, it showed an effect of 83.1% reduction in exposure radiation dose (mR). Therefore, AEC system could be used as dose reduction technology if it understood and used related regulatory factors and physical characteristics.

Analysis of Domestic and Overseas Radioactive Waste Maritime Transportation and Dose Assessment for the Public by Sinking Accident (국내·외 방사성폐기물 해상운반 현황 및 침몰사고 시 일반인 선량평가 사례 분석)

  • Ga Eun Oh;Min Woo Kwak;Hyeok Jae Kim;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.35-42
    • /
    • 2024
  • Demand for RW transportation is expected to increase due to the continuous generation of RW from nuclear power plants and facilities, decommissioning of plants, and saturation of spent fuel temporary storage facilities. The locational aspect of plants and radiation protection optimization for the public have led to an increasing demand for maritime transportation, necessitating to apprehend the overseas and domestic current status. Given the potential long-term radiological impact on the public in the event of a sinking accident, a pre-transportation exposure assessment is necessary. The objective of this study is to investigate the overseas and domestic RW maritime transportation current status and overseas dose assessment cases for the public in sinking accident. Selected countries, including Japan, UK, Sweden, and Korea, were examined for transport cases, Japan and the U.S were chosen for dose assessment case in sinking accidents. As a result of the maritime transportation case analysis, it was performed between nuclear power plants and reprocessing facilities, from plants to disposal or intermediate storage facilities. HLW and MOX fuel were transported using INF 3 shipments, and all transports were performed low speed of 13 kn or less. As a result of the dose assessment for the public in sinking accident, japan conducted an assessment for the sinking of spent fuel and vitrified HLW, and the U.S conducted for the sinking of spent fuel. Both countries considered external exposure through swimming and working at seashore, and internal exposure through seafood ingestion as exposure pathway. Additionally, Japan considered external exposure through working on board and fishing, and the U.S considered internal exposure through spray inhalation and desalinized water and salt ingestion. Internal exposure through seafood ingestion had the largest dose contribution. The average public exposure dose was 20 years after the sinking, 0.04 mSv yr-1 for spent fuel and 5 years after the sinking, 0.03 mSv yr-1 for vitrified HLW in Japan. In the U.S, it was 1.81 mSv yr-1 5 years after the sinking of spent fuel. The results of this study will be used as fundamental data for maritime transportation of domestic RW in the future.

A study on pressurizer cutting scenario for radiation dose reduction for workers using VISIPLAN

  • Lee, Hak Yun;Kim, Sun Il;Song, Jong Soon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2736-2747
    • /
    • 2022
  • The operations in the design lifecycle of a nuclear power plant targeted to be decommissioned lead to neutron activation. Operations in the decommissioning process include cutting, decontamination, disposal, and processing. Among these, cutting is done close to the target material, and thus workers are exposed to radiation. As there are only a few studies on pressurizers, there arises the need for further research to assess the radiation exposure dose. This study obtained the specifications of the AP1000 pressurizer of Westinghouse and the distribution of radionuclide inventory of a pressurizer in a pressurised water reactor for evaluation based on literature studies. A cutting scenario was created to develop an optimal method so that the cut pieces fill a radioactive solid waste drum with dimensions 0.571 m × 0.834 m. The estimated exposure dose, estimated using the tool VISIPLAN SW, in terms of the decontamination factor (DF) ranged from DF-0 to DF-100, indicating that DF-90 and DF-100 meet the ICRP recommendation on exposure dose 0.0057 mSv/h. At the end of the study, although flame cutting was considered the most efficient method in terms of cutting speed, laser cutting was the most reasonable one in terms of the financial aspects and secondary waste.

Comparison of Exposure dose according to the C-arm Angle Change (C-arm 각도 변화에 따른 피폭선량 비교)

  • Shin, Seong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.453-458
    • /
    • 2011
  • This study aimed to figure out the change of exposure dose to the radiologist according to the C-arm angle change. For the exam it was fixed with 101 kvp and 4.9mA for the exposure time with 3 seconds and 5 seconds respectively. C-arm Tube was located both under and over, then the average was taken after performing for 5 times with the change of angle from -30 degree to 0, 30, 60 and 90 degree. The detector measured in 160cm high from the position of the radiologist who operates the C-arm. The measurement was shown its highest result at -30 degree followed by 0, 30, 60, 90 from the highest order. Over tube method is higher than under tube method. Therefore, to reduce the exposure dose of the radiologist, it is required for using under tube method instead of over tube method. When the angle change is made, it is recommended to use the angle that tube is growing further apart from the radiologist. And it is also necessary to shorten exposed time as much as possible to create the same quality image and also to reduce the exposure dose.

The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography (디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2012
  • In digital mammography, Exposure factor were automatically chosen using by measurement breast thickness and the density of mammary gland. It may cause a increase glandular dose. The purpose of this study was to investigate optimal image quality in digital magnification mammography to decrease radiation exposure of patient dose. Auto mode gives the best image quality however, AGD showed better image quality. Image quality of manual mode passed phantom test and SNR at 55% mAs of auto mode commonly used in the digital magnification mammography. Also it could reduce AGD. According to result, manual mode may reduce the unnecessary radiation exposure in digital magnification mammography.

Changes of Pulmonary Function!) During 60 days of Welding Fume Exposure Period 1m Sprague-Dawley Rats (Sprague-Dawley 랫드에서 60일간 용접흄 폭로에 의한 폐기능 변화)

  • 성재혁;최병길;맹승희;김수진;정용현;한정희;현진숙;송경석;조영봉
    • Toxicological Research
    • /
    • v.20 no.1
    • /
    • pp.55-61
    • /
    • 2004
  • Respiratory effects in full time welders include bronchitis, airway irritation, lung function changes, and lung fibrosis. Welder's pneumoconiosis has been generally determined to be benign and not associated with respiratory symptoms based on the absence of pulmonary function abnormalities in welders with marked radiographic abnormalities. Accordingly, to investigate pulmonary function changes during 60 days induced by welding-fume exposure, male Sprague-Dawley rats were exposed to manual metal arc-stainless steel (MMA-SS) welding fumes with concentrations of 64.8$\pm$0.9 mg/$m^3$ (low dose) and 107.8 $\pm$ 2.6 mg/$m^3$ (high dose) total suspended particulates for 2 hr/day, 5 days/week in an inhalation chamber for 60 days. Pulmonary function was measured every week with whole body plethysmograph compensated (WBP Comp, SFT38116, Buxco Electronics, Sharon, CT). The rats exposed to the high dose of welding fumes exhibited statistically significant (p<0.05~0.01) body weight decrease as compared to the control whereas cell number increase of the bronchoalveolar lavage fluid (BALF) (total cell, macrophage, polymorphonuclear cell and lymphocyte) during the 60 days exposure period. And only tidal volume was significantly decreased in dosedependantly during 60 days of MMA-SS welding fume exposure. This pulmonary function change with inflammatory cell recruitment confirms the lung injury caused by the MMA-SS welding fume exposure.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

A Study on the Radiation Dose in Computed Tomographic Examinations (전산화단층촬영 검사의 방사선 선량에 관한 연구)

  • Lim, Chung-Hwang;Cho, Jung-Keun;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.381-389
    • /
    • 2007
  • The purpose of this study is investigation of radiation dose in CT scan. Data were collected from various references and organizations. Doses measured by CT scanners of each medical organization were analyzed and they were calculated through the examination protocol. The results are as follows : 1. $CTDI_W$ value per 100mAs measured by Head Phantom was the highest in <4-slice MDCT scanner> of 24.20 mGy. $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 2. $CTDI_W$ value per 100 mAs measured using body phantom was the highest in <4-slice MDCT scanner> of 13.58 mGy and the $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 3. When contrast medium was not used, the highest scanner was <16 slice MDCT> of $818.83\;mGy{\codt}cm$ in exposure dose in brain scan(p < 0.05). When the contrast medium was used, the highest scanner was <4 slice MDCT> and its average was $1,460.77\;mGy{\cdot}cm$(p < 0.1). 4. When the contrast medium was not used, the highest scanner was <16-slice MDCT> of $521.63\;mGy{\cdot}cm$ on average in terms of the exposure dose in chest inspection(p<0.05). when the contrast medium was used, the highest scanner was found in 8 slice MDCT scanner and its average was $1,174.70\;mGy{\cdot}cm$. There was no statistically significant difference among scanners. 5. When the contrast medium was not used, the highest scanner was <16-slice MDCT> and its average was $856.27\;mGy{\cdot}cm$ in exposure dose on the abdomen-pelvis(p<0.05). when the contrast medium was used, the highest scanner was <16-slice MDCT> and its average was $1,720.64\;mGy{\cdot}cm$ on average (p < 0.05). 6. When the contrast medium was not used, the highest scanner was <8-slice MDCT> and its average was $612.07\;mGy{\cdot}cm$ in exposure dose in liver inspection(p < 0.05). when the contrast medium was used, the highest scanner was <8-slice MDCT scanner> and its average was $2,197.93\;mGy{\cdot}cm$ in exposure dose(p < 0.1). seventy six point two percent of medical facilities were in risk of radiation exposure while the number of phase was three to four times in their dose inspection of contrast medium.

  • PDF

Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography (흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.139-145
    • /
    • 2021
  • This study is to confirm the range of tube voltage for Chest X-ray in DR system by comparing with dose area product (DAP) and effective dose in efficient detector exposure index (DEI) range. GE definium 8000 was used to for the phantom study. The range of tube voltage is 60~130 kVp and of mAs is 2.5~40 mAs. The acquired images were classified into efficient DEI groups, then calculated effective dose with DAP by using a PC-Based Monte Carlo Program 2.0. The signal to noise ratio (SNR) was measured at 4 regions, including the thoracic spine, the lung area with the ribs, the lung area without the ribs, and the liver by using Picture Archiving and Communication System. The significance of the group for each tube voltage was verified by performing the kruskal-wallis test and the mann-whitney test as a post-test. When set to 4 groups dependned on the tube voltage, DAP showed significant differences; 60 kVp and 80 kVp, and 60 kVp and 90 kVp (p= 0.034, 0.021). Effective dose exhibited no statistically significant differences from the all of the group (p>0.05). SNR exhibited statistically significant differences from the all of the group in the liver except compared to 80 kVp and 90 kVp (p<0.05). Therefore, high tube voltages of 100 kVp or more need to be reconsidered in terms of patient dose and imaging in order to represent an appropriate chest X-ray image in a digital system.

Reduction of Exposure dose in Cheat Roentgenography (흉부X선검사(胸部X線檢査)에 있어서 피폭선량(被曝線量)의 경감(輕減)에 대한 검토(檢討))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.15-22
    • /
    • 1979
  • Author made a experiment on the exposure dose with various intensifying screens in taking chest roentgenogram and obtained the results as follows; 1. Special speed type was the most sensitive intensifying screen, the r(gamma) value of this screen was distributed from 2.6 to 2.9. 2. The resolution activity of intensifying screen was inversely proportional to its sensitivity. If, the sensitivity and detail of the fine detail speed type intensifying screen at 100 KV were 100, those of the special speed type were 549 and 54.44 respectively. 3. If the exposure dose of the fine detail type intensifying screen was 1.0 at 60 KV, that of the special speed type intensifying screen was 0.1 at 80KV, and the skin dose of patient was as follows; it was 64.8 mRad at 60KV in mid speed type, 8.1 mRad at 80KV in super high speed type, and 7.2 mRad at 80KV in special speed type intensifying screen respectively.

  • PDF