• Title/Summary/Keyword: Experimental verification

Search Result 1,663, Processing Time 0.031 seconds

Experimental Verification on Motion Error Analysis Method of Hydrostatic Tables Using Transfer Function (전달함수를 이용한 유정압테이블 운동정밀도 해석법의 실험적 검증)

  • Oh, Yoon-Jin;Park, Chun-Hong;Lee, Chan-Hong;Hong, Joon-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.5
    • /
    • pp.64-71
    • /
    • 2002
  • A new model utilizing a transfer function was proposed in the previous paper fur analizing motion errors of hydrostatic tables. Validity of the proposed method was theoretically verified as the calculated motion errors were compared with the results by conventional multi pad method. In this paper, relationship between form error of rail and motion errors of hydrostatic table is analized theoretically in order to comprehand so-called ‘averaging effect of oil film’. Experiments on the motion errors of hydrostatic table is conducted with 3 different rails, and the results are compared with the results calculated by Transfer Function Method. The results show good agreement. From the results, it is verified that TFM is very effective to analize the motion errors of hydrostatic table.

The study of three dimentional flow field using defocusing method in micromixer (Defocusing 기법을 이용한 마이크로 믹서내의 3 차원 유동장 측정연구)

  • Kim, Su-Heon;Yoon, Sang-Youl;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.99-102
    • /
    • 2005
  • This study was conducted for obtaining the optimized data to build the mixer or micro fluid device as measuring the three dimensions flow field in micro mixer. To acquire the rapid diffusion on the region of low Reynolds (Re < 100), the staggered herringbone mixer using chaotic advection was selected in this case. At first, by conducting the numerical analytical virtual experiment using CFD-ACE+, three dimensions flow field in the micro mixer was estimated As this flow field was proven using defocusing particle tracing method, the behavior of micro flow with three dimensional aspects could be analyzed. Numerical analysis and flow pattern in the micro mixer by experimental verification made to be able to analyze the chaotic advection. These can be important sources for building more optimized form. Verifying the information of three dimensional flow structure, these information can be used as the data for developing and improving the $\mu$ -TAS.

  • PDF

An Experimental Study on the Verification of Prediction System of Concrete Strength Using Artificial Neural Networks (인공신경망을 이용한 강도추정 시스템의 검증에 관한 실험적 연구)

  • Song Min Seob;Park Jong Ho;Kim Kab Soo;Jang Jong Ho;Lim Jae Hong;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.446-449
    • /
    • 2004
  • Traditional prediction models have been developed with a fixed equation from based on the limited number of data and parameters. If new data is quite different from original data, then the model should update not only its coefficients but also its equation form. However, artificial neural network dose not need a specific equation form. Instead of that, it needs enough input-output data. Also, it can continuously re-train the new data, so that it can conveniently adapt to new data. Therefore, the purpose of this study is to verify faith and application of prediction system of concrete strength using artificial neural networks through mock-up test.

  • PDF

A Nonlinear Finite Element Analysis to Study the Flexural Behavior of Reinforced Concrete Walls (철근콘크리트 벽체의 휨거동에 관한 비선형 유한요소해석)

  • Han Min Ki;Park Wan Shin;Han Byung Chan;Hwang Sun Kyoung;Choi Chang Sik;Yun Hyun Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.520-523
    • /
    • 2004
  • The finite element method(FEM) models were developed for the reinforced concrete flexural walls and analysed under constant axial and monotonic lateral load using ABAQUS. The major objective of the present study is to determine if the ABAQUS finite element program can be used to accurately model the post-cracked mode of failure in plastic regions of walls, and, if so, to develop practical failure criteria in the plastic range of the material response. The research comprises constitutive models to represent behavior of the materials that compose a wall on the basis of experimental data, development of techniques that are appropriate for analysis of reinforced concrete structures, verification, and calibration of the global model for reinforced concrete walls of increasing complexity. Results from the analyses of these FEM models offers significant insight into the flexural behavior of benchmark data.

  • PDF

The Relationship between Welding Conditions and Ultrasonic Reflection Coefficients of Dissimilar Metals Friction Welded Joints (이종재 막찰용접 이음부에서의 초음파 반사계수와 용접조건과의 관계)

  • 오세규;김동조;한상덕
    • Journal of Ocean Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.138-143
    • /
    • 1987
  • Friction welding has emerged as a reliable process for high-production commercial applications with significant economic and technical advantages. But nondestructive test in friction weld was not clearly developed. Therefore the experimental verification is necessary in order to understand the characteristcs of the pulse echo effects according to various change in welding conditions. This paper presents an attempt to determine the relationship between the varios welding conditions and the coefficients of reflection using the ultrasonic pulse echo method in dissibilar metals friction weld. The new approach of calculating the coefficients of reflection based on measured amplitudes of the echoes is applied in this paper. These coefficients provides a single quantitative measurement which involves both acoustic energy reflected at the welded interface as well as transmitted across the interface. As a result, it was known that the quantitave relationship between welding conditions and the coefficients of reflection using the ultrasonic pulse echo exists in dissimilar metals friction weld.

  • PDF

Characteristics of Parallel Winding Drive of SRM (SRM의 병렬권선 운전 특성)

  • Hwang, Hyung-Jin;Park, Sung-Jun;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.66-68
    • /
    • 2003
  • In a motor drive, the current rating is directly related to the rating of a switching device, and the parallel switching operation for a cost reduction is the alternatives because it has the smaller current rating through current division. There are many investigations for the parallel switching operations to equaling the current division. However it remains many problems for practical usage. This paper proposes a new parallel operation which uses a parallel phase winding to remove the traditional effect of switching device such as saturation voltage according to the division of current. The proposed strategy is verified by theoretical and experimental verification.

  • PDF

Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Series Active Filter (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식)

  • Ji, Jun-Keun;Kim, Jang-Hwan;Sul, Seung-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.538-546
    • /
    • 2007
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently. In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state. Therefore the experimental results to prototype UPS system having power rating of 60kVA is shown to prove the verification of voltage control strategy.

An Experimental Study on the Greenery Ratio of coffee Shop based the Computer Graphics (컴퓨터 그랙픽을 이용한 커피숍 녹시율에 관한 시뮬레이션 실험연구)

  • 안옥희
    • Korean Institute of Interior Design Journal
    • /
    • no.17
    • /
    • pp.60-64
    • /
    • 1998
  • The results of simulation on greenery ratio using CG are as follows: arrangement type of optimal condition and greenery ratio were summarized as below as dispersion type and 5% ratio greenery for 20 pairs of assessment items and these assessment items were classified into 5 factors as a result of factor analysis,. These factors were Harmony Animation Atmosphere texture Peculiarity. Verification results of factors differences according to each condition can be. there was no apparent difference among factors in accordance with gender, In case of arrangement type dispersion type was higher than concentration type in all factors. Based on the above results dispersion type was assessed higher than concentration type the most suitable condition of Harmony Factor was 5% dispersion type Animation Factor was 5% dispersion type Animation Factor was 7% dispersion type Atmosphere Factor was 10% dispersion type Texture Factor was 5% concentration type and $\ulcorner$Peculiarity Factor$\lrcorner$was 7% concentration type.

  • PDF

Verification of New Family for Cascade Multilevel Inverters with Reduction of Components

  • Banaei, M.R.;Salary, E.
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.245-254
    • /
    • 2011
  • This paper presents a new group for multilevel converter that operates as symmetric and asymmetric state. The proposed multilevel converter generates DC voltage levels similar to other topologies with less number of semiconductor switches. It results in the reduction of the number of switches, losses, installation area, and converter cost. To verify the voltage injection capabilities of the proposed inverter, the proposed topology is used in dynamic voltage restorer (DVR) to restore load voltage. The operation and performance of the proposed multilevel converters are verified by simulation using SIMULINK/MATLAB and experimental results.

Carrier based SVPWM Method for Multi-Level System Considering Harmonic Distortion Factor

  • Lee, Yo-Han;Kim, Dong-Hyun;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.26-35
    • /
    • 2001
  • In most inverter/converter applications SVPWM method is a preferred approach since it shows good characteristics in linear modulation range and waveform quality. In this paper, we propose a new carrier based SVPWM method for multi-level system, First, we survey the conventional carrier based SVPWM method, and investigate the problem of the conventional one for the multi-level system with the focus on the switching frequency harmonic flux trajectories. Finally, we propose a new carrier based SVPWM method that can reduce harmonic distortion. Simulation and experimental results are given for verification of the proposed SVPWM method.

  • PDF