• Title/Summary/Keyword: Experimental verification

Search Result 1,663, Processing Time 0.025 seconds

The Effect of Therapeutic Recreation Program on Cognitive Functions and Balance in Elderly People with Alzheimer's Dementia (레크리에이션 치료 프로그램이 치매 노인들의 인지기능과 균형감각에 미치는 영향)

  • Park, Eunsik
    • Journal of Digital Convergence
    • /
    • v.16 no.9
    • /
    • pp.391-397
    • /
    • 2018
  • The purpose of this study was to explore the effect of recreation therapy program on cognitive function and balance sensation of demented elderly patients. The subjects were 16 elderly patients diagnosed with Alzheimer's dementia, divided into experimental group and control group. Recreation therapy program was provided to experimental group for 6 months and the change of cognitive function and balance before and after treatment was analyzed in both groups. The research concluded that the recreation therapy program maintained or even enhanced cognitive function and balance in the elderly with Alzheimer's dementia. The development along with the verification of effectiveness of non-pharmacological methods such as recreational therapy contributed to the study of treatment for the elderly with dementia.

Analysis of Power Saving Factor for a DVS Based Multimedia Processor (DVS 기반 멀티미디어 프로세서의 전력절감율 분석)

  • Kim Byoung-Il;Chang Tae-Gyu
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.1
    • /
    • pp.95-100
    • /
    • 2005
  • This paper proposes a DVS method which effectively reduces the power consumption of multimedia signal processor. Analytic derivations of effective range of its power saving factor are obtained with the assumption of a Gaussian distribution for the frame-based computational burden of the multimedia processor. A closed form equation of the power saving factor is derived in terms of the mean-standard deviation of the distribution. An MPEG-2 video decoder algorithm and AAC encoder algorithm are tested on ARM9 RISC processor for the experimental verification of the power saying of the proposed DVS approach. The experimental results with diverse MPEG-2 video and audio files show 50~30% power saving factor and show good agreement with those of the analytically derived values.

Development and Effects of a Sex Education Program with Blended Learning for University Students (대학생을 위한 블렌디드 러닝 기법의 성 교육 프로그램 개발 및 효과)

  • Kim, Il-Ok;Yeom, Gye Jeong;Kim, Mi Jeong
    • Child Health Nursing Research
    • /
    • v.24 no.4
    • /
    • pp.443-453
    • /
    • 2018
  • Purpose: This study was describes the development and implementation a sex education program with a blended learning method for university students. Methods: Sixty-eight university students were recruited either to the experimental group (n=35) or the control group (n=33). This program was developed based on the analysis, design, development, implementation, and evaluation model. The analysis phase consisted of a literature review, focus group interview, expert consultations, and target group survey. In addition, learning objectives and structure were designed, and a printed text-book, presentation slides, cross-word puzzle, and debate topics were developed. In the implementation phase, the program was conducted 3 times over the course of 3 weeks. The evaluation phase involved verification of the effects of the program on sex-related knowledge, sexual autonomy, and justification of violence, as well as an assessment of satisfaction with the program. Results: The experimental group had significantly higher scores on sex-related knowledge (t=5.47, p<.001), sexual autonomy (t=2.40, p=.019), and justification of violence (t=2.52, p=.015) than the control group. Conclusion: The results indicate that this sex education program with blended learning was effective in meeting the needs of university students and can be widely used in this context.

Full-scale experimental verification on the vibration control of stay cable using optimally tuned MR damper

  • Huang, Hongwei;Liu, Jiangyun;Sun, Limin
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.1003-1021
    • /
    • 2015
  • MR dampers have been proposed for the control of cable vibration of cable-stayed bridge in recent years due to their high performance and low energy consumption. However, the highly nonlinear feature of MR dampers makes them difficult to be designed with efficient semi-active control algorithms. Simulation study has previously been carried out on the cable-MR damper system using a semi-active control algorithm derived based on the universal design curve of dampers and a bilinear mechanical model of the MR damper. This paper aims to verify the effectiveness of the MR damper for mitigating cable vibration through a full-scale experimental test, using the same semi-active control strategy as in the simulation study. A long stay cable fabricated for a real bridge was set-up with the MR damper installed. The cable was excited under both free and forced vibrations. Different test scenarios were considered where the MR damper was tuned as passive damper with minimum or maximum input current, or the input current of the damper was changed according to the proposed semi-active control algorithm. The effectiveness of the MR damper for controlling the cable vibration was assessed through computing the damping ratio of the cable for free vibration and the root mean square value of acceleration of the cable for forced vibration.

Effects of Ground Faults on the Safety of Persons in High Voltage Distribution Systems (고압계통 지락고장시 인체안전에 미치는 영향)

  • Kang, Sung-Man;Kim, Han-Soo;Lee, Jong-Chul;Lee, Ju-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.195-197
    • /
    • 2007
  • This paper presents experimental results on the safety of persons due to a ground fault in 22.9 kV-Y distribution system In order to evaluate the touch voltages due to internal ground faults in a step down transformer based on the newly prescribed KS C IEC 60364 standard series, the verification tests in a 22.9 kV multi-grounded neutral system were carried out From the experimental results, it was found that there will be significant potential rise jeopardizing LV equipment insulation in case of separate grounding between HV and LV system and the effective measures against hazardous touch voltages due to a IN side ground fault in the common grounding system between HV and LV system are proposed. As a consequence, it was found that the equipotential bonding is an important prerequisite for the effectiveness of the protective measures for the safety of persons in the common ground system between 22.9 kV-Y and low-voltage grounding system.

  • PDF

A Study on the Performance Test and Verification of Heat Transfer characteristics in Automobile Rear Window Heater (자동차 후면 유리 열선의 열전달특성에 따른 성애제거 성능평가 및 성능검증 방법에 관한 연구)

  • Juen, H.Y.;Lee, C.K.;Bae, H.J.;Lee, S.J.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.73-80
    • /
    • 2005
  • Both theoretical and experimental investigations were conducted to analyze defrosting behavior of a window heater operating in the low outdoor temperature($-20^{\circ}C$). To achieve this purpose, first a warm-chamber experiment($23^{\circ}C$) was performed to measure inner and outer surface temperature of the rear window(heated by the electric heater supplying 195 W) as functions of both time and position. Secondly, a cold chamber experiment was made to continuously record defrosting process of the frosted window. From the comparisons of the two experimental results, it was found that there was a similarity between the spatial distributions of both temperature and remaining frost. Thus, the temperature data from the warm-chamber experiments can be utilized to predict an expected zone covered with remaining frosts, and this approach can also be adopted in the inspection process in order to economically guarantee optimized performance of the window heater. Finally, an analytical model based on one-dimensional, steady-state heat transfer theories was proposed and successfully predicted the outer surface temperature of the rear window surrounded by cold air($-20^{\circ}C$) for the given operating conditions(heater power, inside and outside heat transfer coefficients, and surrounding air temperature, etc.).

  • PDF

A Position Sensorless Control System of SRM using Neural Network (신경회로망을 이용한 위치센서 없는 스위치드 릴럭턴스 전동기의 제어시스템)

  • 김민회;백원식;이상석;박찬규
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.246-252
    • /
    • 2004
  • This paper presents a position sensorless control system of Switched Reluctance Motor (SRM) using neural network. The control of SRM depends on the commutation of the stator phases in synchronism with the rotor position. The position sensing requirement increases the overall cost and complexity. In this paper, the current-flux-rotor position lookup table based position sensorless operation of SRM is presented. Neural network is used to construct the current-flux-rotor position lookup table, and is trained by sufficient experimental data. Experimental results for a 1-hp SRM is presented for the verification of the proposed sensorless algorithm.

A Numerical Analysis on the Heat Transfer Characterristics of Magnetic Fluid in a Rectangular Enclosure (자성유체의 밀폐공간내 열전달특성에 관한 수치적 연구)

  • Ryu Shin-Oh;Park Myung-Ho;Park Gil-Moon;Park Joung-Woo;Seo Lee-Soo;Chen Chel-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.1 s.18
    • /
    • pp.37-43
    • /
    • 2003
  • Natural convection of a magnetic fluid is different from that of Newtonian fluids because a magnetic body force exists in an addition to gravity and buoyancy forces. In this paper, the natural convection of a magnetic fluids (W-40) in a rectangular enclosure is investigated by numerical and experimental methods. One side wall is kept at a constant temperature ($25^{\circ}C$), and the opposite side wall is also kept at a constant temperature ($20^{\circ}C$), Under above conditions, the magnitude of the magnetic fields were varied and applied. GSMAC scheme is used for the numerical method, and the thermo-sensitive liquid crystal film (R20C5A) is utilized in order to visualize wall-temperature distributions as an experimental verification. This study has resulted in the following fact that the natural convection of a magnetic fluid is controlled by the direction and intensity of the magnetic fields.

Selection and Verification of 3D Finite Element Method Model for Silicone Foot Sensor with Low Detection Pressure (낮은 감지 압력신호 값을 가지는 실리콘 족적 센서에 대한 3차원 유한요소 해석 모델 선정 및 검증)

  • Seong, Byuck Kyung;Seo, Hyung Kyu;Kim, Dong Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.11
    • /
    • pp.1299-1307
    • /
    • 2014
  • In this work, an appropriate analysis model of a precise foot sensor with low detection pressure capability under a low range of variation in the dimensional variables was proposed. With a simple two-dimensional model, it was found that a remarkably high error level sometimes occurred between the analysis and experimental results. In order to overcome the error and improve the performance, a three-dimensional model was introduced, and the detection pressure and sensor characteristics were compared with those of the experimental results, which showed its enhanced performance with less error and higher precision.

The effect of permanent magnet in MAP of magnesium alloy for external case of notebook compute (노트북 케이스용 마그네슘의 자기연마가공에서 영구자석의 효과)

  • Kim, Sang-Oh;Gang, Dea-Min;Kwak, Jae-Seob;Jung, Young-Deug
    • Design & Manufacturing
    • /
    • v.6 no.2
    • /
    • pp.48-53
    • /
    • 2012
  • In previous study, it showed that the MAP was greatly effective polishing process for magnesium plate. But it had lower efficiency than magnetic materials such as SM45C. It was very difficult to cut non-magnetic materials using the MAP process because the process was fundamentally possible by help of a magnetic force. This study aimed to verify analytically formation of the magnetic field in a case of the non-magnetic materials especially focused on magnesium plate. So, In this study, the magnetic density flux was predicted using simulation program. As a result, the magnetic density flux was lower at the center of pole on inductor than outside. It had same result on the experimental verification. And magnetic force was lower according to increase of working gap. So, to improve the magnetic force, permanent magnet was installed under the workpiece. In that case, the magnetic density flux not only at center but also at outside of pole was increased. Therefore, the efficiency of magnetic abrasive polishing was also increased. A design of experimental method was adopted for assessment of parameters' effect on the MAP results of magnesium plate for improving the magnetic force.

  • PDF