• Title/Summary/Keyword: Experimental verification

Search Result 1,663, Processing Time 0.025 seconds

A Study on the Fault Analysis for a Micro Smart Grid Simulator Design Using MEMS' Miniaturization Technology (MEMS의 소형화 기술을 이용한 마이크로 스마트 그리드 시뮬레이터 설계를 위한 고장해석법에 대한 연구)

  • Ko, Yun-Seok;Oh, Se-Pil;Kim, Hyo-Seong;Kim, In-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.2
    • /
    • pp.315-324
    • /
    • 2017
  • The smart grid with distributed power supply introduces a number of problems including not only the problems of the existing power grid but also the problem of protection co-operation due to new electric phenomenon because it has a mixed operation structure combining the existing radial operation structure and the new loop operation structure. The EMTP based power system analysis method has flexibility and convenience from the view of system configuration but it requires another experimental verification because of uncertainty of design and analysis results. On the other hand, the real demonstration system has difficulties in observing accurate fault on large scale system due to considerable economical and spatial construction cost, system configuration constraint, and it is difficult to demonstrate the distributed, autonomous and adaptive control strategy of smart grid. In this paper, a basic theory for a micro smart grid simulator design using MEMS(Micro Electro-Mechanical Systems) miniaturization technology is studied which can safely and freely experiment and observe electrical phenomena, and distribution, autonomous adaptive control strategy for disturbances on 22.9kV smart grid under minimum economic and spatial cost.

Improvement and Verification of TMFT Power Circuit Design (전술다기능단말기(TMFT)의 전원회로 설계 개선 및 검증)

  • Kim, Jin-Sung;Kim, Byung-Jun;Kim, Byung-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.357-362
    • /
    • 2020
  • The TMFT, a sub-system of TINC, provides voice calls, data transmission and reception, and multimedia services to individual users. At the time of development in 2011, the power circuit of the TMFT was designed to electrical power supply to each device via a charger IC. However, the newly improved power supply circuit allows power to be supplied to each device through the PMIC without configuring the charger IC separately. In this paper, the power circuit design structure of TMFT applied in the development stage and the improved power circuit design structure were compared. And we verified through experiments whether the improved power circuit can be applied to TMFT. The experimental method was verified by directly comparing the current consumption test, charge time comparison test, and rising temperature test during charging each of before and after improvement terminals.

Development of Three Dimensional Fracture Strain Surface in Average Stress Triaxiaility and Average Normalized Lode Parameter Domain for Arctic High Tensile Steel: Part I Theoretical Background and Experimental Studies (극한지용 고장력강의 평균 응력 삼축비 및 평균 정규 로드 파라메터를 고려한 3차원 파단 변형률 평면 개발: 제1부 이론적 배경과 실험적 연구)

  • Chong, Joonmo;Park, Sung-Ju;Kim, Younghun
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.445-453
    • /
    • 2015
  • The stress triaxiality and lode angle are known to be most dominant fracture parameters in ductile materials. This paper proposes a three-dimensional failure strain surface for a ductile steel, called a low-temperature high-tensile steel (EH36), using average stress triaxiality and average normalized lode parameter, along with briefly introducing their theoretical background. It is an extension of previous works by Choung et al. (2011; 2012; 2014a; 2014b) and Choung and Nam (2013), in which a two-dimensional failure strain locus was presented. A series of tests for specially designed specimens that were expected to fail in the shear mode, shear-tension mode, and compression mode was conducted to develop a three-dimensional fracture surface covering wide ranges for the two parameters. This paper discusses the test procedures for three different tests in detail. The tensile force versus stroke data are presented as the results of these tests and will be used for the verification of numerical simulations and fracture identifications in Part II.

Analysis of Variables Influencing the Pressure Build-up and Volume Expansion of Kimchi Package (김치포장의 압력 및 부피 변화에 영향을 미치는 인자의 분석)

  • 이동선;최홍식;박완수
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.2
    • /
    • pp.429-437
    • /
    • 1999
  • A mathematical model was established for estimating changes in pressure and volume of permeable kimchi packages. The model comprises the CO2 gas production from kimchi and permeation of O2, CO2 and N2 through the permeable film or sheet. Using the developed model, the effects of various packaging variables on the pressure and volume changes were analyzed for rigid and flexible packag es of kimchi(3% salt content) at 15oC, and then effect of storage temperature was also looked into. In case of rigid pack of 400g, using the plastic sheet of high CO2 permeability and initial vacuumizing can help to relieve the problem of pressure build up. The lower fill weight can further reduce the pressure, but will result in higher packaging cost. For the flexible package of 3 kg, highly permeable films such as low density polyethylene(LDPE) and polypropylene can reduce the volume expansion. Higher ratio of CO2 permeability to O2 and N2 permeabilities are effective in reducing the volume expansion. Increased surface area cannot contribute to reduction of volume expansion for highly permeable flexible packages of kimchi. For the impermeable packages, pressure and volume at over ripening stage (acidity 1.0%) increase with decreased temperature, while those at optimum ripening stage(acidity 0.6%) change little with temperature. Pressure of permeable rigid LDPE package increases with tem perature at any ripening stage, and temperature affects the volume of flexible LDPE package very slightly. Experimental verification of the present results and package design with economical consid eration are needed as a next step for practical application.

  • PDF

An Experimental Verification on the Efficiency of Geosynthetics on Crushed Stone Layer (쇄석배수층에 적용된 토목섬유의 효율성에 대한 실험적 검증)

  • Park, Min-Cheol;Im, Eun-Sang;Kim, Jae-Hong;Han, Heui-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.11
    • /
    • pp.17-27
    • /
    • 2013
  • This study is to prove the efficiency of geo-synthetics on the crushed stone layer by experiments. The strength of PET mat as reinforcing soft ground was verified through the loading experiments. Also, PP mat was used to protect the blockage of crushed stone layer by the filled soil, whose efficiency was examined according to loading and infiltration conditions. The crushed stones were penetrated into clay layer if the PET mat was removed, which was verified by loading experiments. In addition, the cohesioness of soil without PP mat made the blockage of stone layer easily, which reduced the infiltration capacity by about 98%.

New Control Method for Power Decoupling of Electrolytic Capacitor-less Photovoltaic Micro-Inverter with Primary Side Regulation

  • Irfan, Mohammad Sameer;Shin, Jong-Hyun;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.677-687
    • /
    • 2018
  • This paper presents a novel power decoupling control scheme with the bidirectional buck-boost converter for primary-side regulation photovoltaic (PV) micro-inverter. With the proposed power decoupling control scheme, small-capacitance film capacitors are used to overcome the life-span and reliability limitations of the large-capacitance electrolytic capacitors. Then, an improved flyback PV inverter is employed in continuous conduction mode with primary-side regulation for the PV power conditioning. The proposed power-decoupling controller shares the reference for primary side current regulation of the flyback PV inverter. The decoupling controller shapes the input current of the bidirectional buck-boost converter. The shared reference eliminates the phase-delay between the input current to the bidirectional buck-boost converter and the double frequency current at the PV primary current. The elimination of the phase-delay in dynamic response enhances the ripple rejection capability of the power decoupling buck-boost converter even with small film capacitor. With proposed power decoupling control scheme, the additional advantage of the primary-side regulation of flyback PV inverter is that there is no need to have an extra current sensor for obtaining the ripplecurrent reference of the decoupling current-controller of the power-decoupling buck-boost converter. Therefore, the proposed power decoupling control scheme is cost-effective as well as the size benefit. A new transient analysis is carried out which includes the source voltage dynamics instead of considering the source voltage as a pure voltage source. For verification of the proposed control scheme, simulation and experimental results are presented.

Experimental Verification on Factors Affecting Core Resistivity Measurements (II)-Characteristics of Time Series Data and Determination Method of Resistivity (코어비저항 측정에 미치는 영향요소에 대한 실험적 고찰(Ⅱ) - 시계열자료의 특성과 대표비저항 값의 결정)

  • Kim, Yeong Hwa;Choe, Ye Gwon
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.4
    • /
    • pp.269-276
    • /
    • 1999
  • As a part of trying to get the resistivity values correctly from laboratory core resistivity measurement, the effect of sample holders in resistivity measurement was analyzed and a better way to determine the representative resistivity value from the time series resistivity data was searched. Modified GS type and modified two-electrode type sample holders were devised and their effects have been compared with those of GS and two-electrode type sample holders. The modified two-electrode type sample holder has benefits both in repetition and simplicity in data acquisition. The analysis of distribution trend of the time series resistivity data obtained with different kind of sample holders and source frequencies shows that the maximum curvature point method gives the best result in determining representative resistivity value.

  • PDF

Output Data Analysis of Simulation: A Review (시뮬레이션 출력 자료 분석에 관한 연구)

  • Chang, Byeong-Yun
    • Journal of the Korea Society for Simulation
    • /
    • v.21 no.3
    • /
    • pp.11-16
    • /
    • 2012
  • Simulation is the imitation of the operation of a real-world process or system over time. It concerns the study of the operating characteristics of real systems. Typically, a simulation project consists of several steps such as data collection, coding, model verification, model validation, experimental design, output data analysis, and implementation. Among these steps of a simulation study this paper focus on statistical analysis methods of simulation output data. Specially, we explain how to develop confidence interval estimators for mean ${\mu}$ in terminating and non-terminating simulation cases. We, then, explore the estimation techniques for $f({\mu})$, where the function $f({\bullet})$ is a nonlinear that is continuously differentiable in a neighborhood of ${\mu}$ with $f'({\mu}){\neq}0$.

Preliminary Structural Design of Blast Hardened Bulkhead (The 1st Report : Formulation of Simplified Structural Analysis/Design Method) (폭발강화격벽의 초기구조설계에 관한 연구 (제1보 : 간이 구조 해석/설계 기법 정식화))

  • Nho, In Sik;Park, Man-Jae;Cho, Yun Sik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.5
    • /
    • pp.371-378
    • /
    • 2018
  • Internal detonation of a warhead inside a compartment of naval vessel can result in serious blast damages including plastic deformation and rupture of the structural members especially bulkhead due to the huge explosive impact pressure, fragments and high temperature flame. To secure watertight integrity and to prevent the domino-type flooding of neighbouring compartments caused by the rupture of bulkheads, it is necessary to develop the structural design technology of Blast Hardened Bulkheads(BHB) which can resist the blast impact pressure of threatening weapons to increase the survivability of naval vessels. This study dealt with the simplified structural response analysis of BHB under impact pressure of confined explosion and aimed to develop the efficient and rational design method of BHB and joint structures which can be applied at initial design stage. The present 1st report dealt with the phenomena of explosive detonation surveying the preceding experimental/theoretical research and the characteristics of time history of blast pressure including the peak value and duration time were examined. And to predict the large plastic deformation behaviors of BHB by the huge blast pressure reasonably, the plastic hinge method including the membrane effects was formulated. It was applied to the simplified structural design equations. The following report will deal with the application and adjustment process of the structural scantling equations to the actual BHB design and verification of validity of them.

Experimental Verification of the Optimized TCN-Ethernet Topology in Autonomous Multi-articulated Vehicles (자율주행형 다관절 차량용 이더넷 TCN의 최적 토폴로지에 대한 실험적 검증)

  • Kim, Jungtai;Hwang, Hwanwoong;Lee, Kang-Won;Yun, Ji-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.6
    • /
    • pp.106-113
    • /
    • 2017
  • In this paper, we propose a suitable network topology for the Ethernet based Train Communication Network (TCN) for control system in a autonomous multi-articulated vehicle. We propose a network topology considering the structural constraints such as the number of cables and ports, and the performance constraints such as network response time and maximum throughput. We compare the network performances of star topology and daisy chain topology as well as hybrid topology, which is proposed in previous studies and a compromise between daisy chain and star topology. Here, the appropriate number of nodes in a group is obtained for the configuration of the hybrid topology. We first derive estimates of the network performance through simulation with different topologies, and then, implement the network by connecting the actual devices with each network topology. The performance of each topology is measured using various network performance measurement programs and the superiority of the proposed topology is described through comparison.