• Title/Summary/Keyword: Experimental measurement

Search Result 5,377, Processing Time 0.036 seconds

Experimental and clinical studies with impedance audiometry; the increase in air volume in the middle ear air system and the pneumatization of human temporal bones (측두골의 함기도와 중이강의 용적이 고막 임피던스에 미치는 영향에 관한 연구)

  • 민양기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.4.4-5
    • /
    • 1977
  • The vibratory energy introduced into the external ear canal is changed by the mechanical factors of eardrum itself, the motility of ossicles, and the air cushion of tympanic cavity and the like. This study was designed to investigate the volume of middle ear cavity and mastoid air cell system as a factor of determining the accoustic impedance of middle ear system. The author studied how the increase in air volume of middle ear cavity effects on the acoustic impedance of middle ear system with dogs' ears and researched the correlation between the degree of pneumatization of temporal bones and the acoustic impedance of middle ear system by comparing the radiological findings of pneumatization (Law's and Towne's projection) with the acoustic impedance measurements with Madsen ZO 70. The result is as follows: 1 The tympanometric findings in control state revealed the curves of type A, and did not change in its configuration by the increase in the air volume of dogs middle ear system. 2. The static compliance of middle ear revealed a distinct and linear increase in proportion to the increase in air volume of middle ear system; the rate of increase was $0.05{\pm}0.02$ cc of static compliance per cc of air volume. 3. Authenticated in the above result and the tendency to increase in static compliance in proportion to the increase in the degree of pneumatization of temporal bones, there was significant regression equation between the degree of pneumatization of temporal bones (x variable) and the static compliance of middle ear system; $y=0.19x{\pm}0.16{\pm}0.05$ It is suggested that the difference in volume of middle ear system plays an important role in the change of the static compliance of middle ear, and the author concludes that the measurement of static compliance of middle ear has clinical value as diagnostic means of evaluating the degree of pneumatization of temporal bones along with some radiological examination.

  • PDF

COMPARATIVE EXPERIMENTAL STUDY ON MEASUREMENT OF ORAL TEMPERATURE WITH DIFFERENT KINDS OF CLINICAL THERMOMETERS -comparison of Oral Temperature and Oral Placement Time among Fahrenheit Glass Thermometer, Electric Thermometer, Yu II centigrade Glass Thermometer, and Kuk II centigrade Glass Thermometer- (각종 체온계의 구강체온측정에 관한 실험적 비교연구 -외제화씨 체온계, 전자체온계 및 국산 섭씨체온계에 의한 측정온도와 측정시간의 비교-)

  • 윤정숙
    • Journal of Korean Academy of Nursing
    • /
    • v.4 no.2
    • /
    • pp.93-106
    • /
    • 1974
  • The purposes of this study are to identify the necessity of utilization of electric thermometer, to determine the difference of clinical thermometers to reach maximum or optimum temperature, and to determine the length of time necessary for temperature taking, with Fahrenheit thermometer, electric thermometer, Yu Ⅱ centigrade thermometer, and Kuk ll centigrade thermometer. The first and second comparative Experiments were' conducted from August 25 through September 30, 1973. In the first experiment, Fahrenheit thermometer, which had been accurately teated two times, and electric thermometer have been utilized. These two kinds of thermometers were inserted simultaneously under the central area of the tongue and the mouth kept closed while thermometers were in place. All temperature readings were done at one minute interval until leaching-maximum temperature. These procedures were repeated one hundred times and the data were-analyzed statistically by means of the t-test. In the second experiment, Fahrenheit thermometer, which had been accurately tested two. times, Yu Ⅱ centigrade thermometer, and Kuk Ⅱ centigrade thermometer have been utilized. These three kinds of thermometers were inserted simultaneously under the central area of the. tongue and the mouth kept closed while thermometer were in place. All temperature readings were done at one minute interval until reaching maximum temperature. These procedures were. repeated one hundred times and the data were analyzed statistically by means of the F-ratio Under the eight hypotheses designed for this study, the findings obtained are as follows: 1. There were no significant differences in the maximum temperature between Fahrenheit thermometer and electric thermometer. The mean maximum temperature for Fahrenheit thermometers was 37.06℃ and for electric thermometer was 37.09℃. 2. The placement time to reach maximum temperature taken by Fahrenheit thermometer was significantly shorter than that by electric thermometer. The mean placement time for Fahrenheit thermometers was 4.04 minutes, for electric thermometer was 5.52 minutes. In the case of Fahrenheit thermometers, 45 to 77 percent after 3 to 5 minutes, over 90 Percent after 7 minutes, and 100 percent after 10 minutes, had reached optimum temperature. When the electric thermometer was used, 23 to 54 percent after 3 to 5 minutes, over 90 percent after 9 minutes, and 100 percent after 12 minutes, had reached optimum temperature. 5. There ware no significant differences in the maximum temperature among Fahrenheit thermometer, Yu Ⅱ centigrade thermometer, and Kuk Ⅱ centigrade thermometer. The mean maximum temperature for Fahrenheit thermometers was 36.67℃, for Yu Ⅱ centigrade thermometer, was 33.73℃, and for Kuk Ⅱ centigrade thermometers was 37.76℃. 6. There were no significant differences in placement time to reach maximum temperature among Fahrenheit thermometer, Yu Ⅱ centigrade Thermometer, and Kuk Ⅱ centigrade thermometer. The mean placement time (or Fahrenheit thermometers was 7.77 minutes, for Yu Ⅱ centigrade thermometers was 7.25 minutes, and Kuk Ⅱ centigrade thermometers was 7.25 minutes. In the case of Fahrenheit thermometers, 8 to 24 percent after 3 to 5 minutes, over 90 percent after 11 minutes, and 100 percent after 13 minutes, had reached maximum temperature. When the Yu Ⅱ centigrade thermometer was used, 10 to 27 percent after 3 to 5 minutes, over 90 percent after 11 minutes, an8 103 percent after 13 minutes, had reached maximum temperature. When the Kuk Ⅱ centigrade thermometer was used, 11 to 27 Percent after 3 to 5 minutes, over 90 percent after 11 minutes, and 100 percent after 12 minutes, had reached maximum temperature. 7. There were no significant differences in the optimum temperature(the maximum temperature minus 0.1℃) among fahrenheit thermometer, Yu Ⅱcentigrade thermometer, and Kuk Ⅱ centigrade thermometer. The mean optimum temperature for Fahrenheit thermometers was 36.60℃, for Yu Ⅱ centigrade thermometers was 36.69℃, and Kuk Ⅱ centigrade thermometers was 36.69℃. 8. There were no significant differences in placement time to reach optimum temperature among Fahrenheit thermometer, Yu Ⅱ centigrade thermometer, and Kuk Ⅱ centigrade thermometer The mean placement time for Fahrenheit thermometers was 5.70 minutes, for Yu Ⅱ centigrade thermometers was 5.54 minutes, and for Kuk Ⅱ centigrade thermometers was 5.28 minutes. In the case of Fahrenheit thermometers, 21 to 49 percent after 3 to 5 minutes, over 90 percent after 9 minutes, and 100 percent after 12 minutes, had reached optimum temperature. When the Yu Ⅱ centigrade thermometer was used, 23 to 51 percent after 3 to 5 minutes over 90 percent after 10 minutes, and 100 percent after 12 minutes, had reached optimum temperature. When the Kuk Ⅱ centigrade Thermometer was used, 23 to 57 Percent after 3 to 5 minutes, over 90 percent after 9 minutes, and 100 Precent after 11 minutes, had reached optimum temperature.

  • PDF

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

Effect of Carrier Confinement and Optical Properties of Two-dimensional Electrons in Al0.3Ga0.7N/GaN and Al0.3Ga0.7N/GaN/Al0.15Ga0.85N/GaN Heterostructures (Al0.3Ga0.7N/GaN 및 Al0.3Ga0.7N/GaN/Al0.15Ga0.85N/GaN 이종접합 구조에서 운반자 구속 효과와 이차원 전자가스의 광학적 특성)

  • Kwack, H.S.;Lee, K.S.;Cho, H.E.;Lee, J.H.;Cho, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.359-364
    • /
    • 2008
  • We have investigated optical and structural properties of $Al_{0.3}Ga_{0.7}N$/GaN and $Al_{0.3}Ga_{0.7}N/GaN/Al_{0.15}Ga_{0.85}N/GaN$ heterostructures (HSs) grown by metal-organic chemical vapor deposition, by means of Hall measurement, high-resolution X-ray diffraction, and temperature- and excitation power-dependent photoluminescence (PL) spectroscopy. A strong GaN band edge emission and its longitudinal optical phonon replicas were observed for all the samples. At 10 K, a 2DEG-related PL peak located at ${\sim}\;3.445\;eV$ was observed for $Al_{0.3}Ga_{0.7}N$/GaN HS, while two 2DEG peaks at ${\sim}\;3.42$ and ${\sim}\;3.445\;eV$ were observed for $Al_{0.3}Ga_{0.7}N/GaN/Al_{0.15}Ga_{0.85}N/GaN$ HS due to the additional $Al_{0.15}Ga_{0.85}N$ layers. Moreover, the emission intensity of the 2DEG peak was higher in $Al_{0.3}Ga_{0.7}N/GaN/Al_{0.15}Ga_{0.85}N/GaN$ HS than in $Al_{0.3}Ga_{0.7}N$/GaN HS probably due to an effective confinement of the photo-excited holes by the additional $Al_{0.15}Ga_{0.85}N$ layers. The 2DEG-related emission intensity decreased with increasing temperature and disappeared at temperatures above 150 K. To investigate the origin of the new 2DEG peaks, the energy-band structure for multiple AlGaN/GaN HSs were simulated and compared with the experimental data. As a result, the observed high- and low-energy peaks of 2DEG can be attributed to the spatially-separated 2DEG emissions formed at different AlGaN/GaN heterointerfaces.

Acute Effects of Ethanol on Blood Pressure and Renal Function in Rat (Ethanol 급성투여(急性投與)가 흰쥐의 혈압(血壓)과 신기능(腎機能)에 미치는 영향(影響))

  • Bae, Gui-Sook;Park, Jae-Sik;Lee, Won-Jung
    • The Korean Journal of Physiology
    • /
    • v.15 no.2
    • /
    • pp.103-109
    • /
    • 1981
  • In order to determine the dose-response relationship of ethanol on blood pressure and renal function, 2 doses of ethanol were intubated into albino rats. For a direct measurement of arterial blood pressure, a polyethylene catheter(PE 10) was implanted in the abdominal aorta, and the other end of the catheter was pulled out of the back of the neck. The experiment was conducted after the rats recovered from the surgery. After emptying their bladders, the rats were placed in a metabolism cage. Mean arterial pressure (MAP) was measured and arterial blood samples were collected through the catheter. Following the collection of the control urine sample, 1 ml of 10 g% (low dose), or 30 g% (high dose) of ethanol/100 g BW was intubated. 1 ml of water/100 g BW was intubated into the control group. MAP and blood samples were taken every hour, and urine samples were collected every 90 min for 3 hours. Blood alcohol concentrations reached a peak at 1 hour (low dose: $105.0{\pm}7.5$, high dose: $214.7{\pm}20.2\;mg%$) and decreased linearly thereafter. Following alcohol ingestion, MAP began to decrease at 15 min and remained at a significantly low level thoughout the 3 hours experimental period(low dose: $112{\pm}2{\rightarrow}102{\pm}4$, high dose: $117{\pm}2{\rightarrow}100{\pm}8\;mmHg$). Urine Flow increased markedly during the first 90 min of ethanol ingestion (low dose: $0.88{\pm}0.20{\rightarrow}1.04{\pm}0.22$, high dose: $0.56{\pm}0.11{\rightarrow}1.35{\pm}0.18\;ml/1.5\;hr$) and decreased during the second 90 min period(low dose: $0.25{\pm}0.06$, high dose: $0.22{\pm}0.06\;ml/1.5\;hr$). Urine flow of the control group decreased gradually during the experiment $(0.88{\pm}0.10{\longrightarrow}0.59{\pm}0.09{\rightarrow}0.45{\pm}0.09\;ml/1.5\;hr)$. These results indicate that the blood-pressure-lowering and diuretic effects of ethanol are dose-related: higher doses of ethanol produce a greater decrease in blood pressure and greater diuresis.

  • PDF

Comparison of Experimental and Radiation Therapy Planning (RTP) Dose Distributions on Air Cavity (공동(air cavity)의 존재 시 실험적 선량분포와 치료계획상의 선량분포 비교)

  • Kim, Yon-Lae;Suh, Tae-Suk;Ko, Shin-Gwan;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study is compared that the dose distribution by experimentation and radiation therapy planning (RTP) when the air cavity region was treated high energy photon. The dose measurements were performed with a 6 MV photon beam of linear accelerator. The polystyrene and self made acyl phantom were similar to tissue density of the human body. A parallel plate chamber was connected to an electrometer. The measurement setup was SCD (Source Chamber Distance) 100 cm and the distance of surface from air cavity was 3 cm. Absorbed dose of interface were measured by area and height. The percent depth dose were measured presence and absence of air cavity, depth according to a ratio of field size and air cavity size. The dose distribution on planning was expressed to do the inhomogeneity correction. As the area of air cavity was increased, the absorbed dose were gradually reduced. It was slightly increased, when the height of air cavity was changed from 0 cm to 0.5 cm. After the point, dose was decreased. In case of presence of air cavity, dose after distal air cavity interface was more great than absence of air cavity. The rebuild up by field size and area of air cavity occurred for field size, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$ and $6{\times}6\;cm^2$, with fixed on area of air cavity, $5{\times}5\;cm^2$. But it didn't occur at $10{\times}10\;cm^2$ field size. On the contrary, the field size was fixed on $5{\times}5\;cm^2$, rebuild up occurred in area of air cavity, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$. but, it did not occur for air cavity, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$. All of the radiation therapy planning were not occurred rebuild up. It was required to pay attention to treat tumor in air cavity because the dose distribution of planning was different from the dose distribution of patient.

An Experimental Study on Establishing Criteria of Gripping Work in Construction Site (건설 현장 악력 작업안전 기준 설정에 관한 실험적 연구)

  • 손기상;이인홍;최만진;안병준
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.81-95
    • /
    • 1995
  • Now, safety assurance in construction sites should be accomplished by its own organization rather than control of the code or government. It is believed that the safety assurance can be considerably improved by a lecture or an education using the existing theories or literatures up to now, but it is thought that fundamental safety assurance we not able to be accomplished without developing safety devices '||'&'||' equipment or taking fundamental measures, based on the result analyzed from workers behaviors. There are various behaviors of the workers showed in construction site, but only tests for hammerusing works such as form, re-bar, stone workers directly related to the grip strength are mainly performed, investigated and measured here for the study. The above works are similar to power grip, 7th picture on seven items which are categorized for hand grip types(Ammermin 1956 ; Jones ; Kobrick 1958). Measurements of grip strength are commonly taken in anthropometric surveys. They are easy to administer but unfortunately it is rather dubious whether they yield any data that are of interest to the engineer. Very fewer controls of tools are grasped and squeesed studies showed very little overall correlation between grip strength and other measures of bodily strength (Laubach, Kromer, and Thordsen 1972), but hammer-using work which is practically progressed in construction site are mainly influenced with grip strength. According to the investigation on work measurement, it is shown that 77% of form worker are using hammer to be related to grip strength. In this study, it is particularly noticed that wearing safety gloves in construction site is required for workers safety but 20% difference between grip strength with safety gloves and without ones are commonly neglected in the site(Fig. 1). Nevertheless, safety operation with consideration of the above 20% difference is not considered in the construction site. Factors of age, kinds of work, working time, with or without safety gloves are in vestigated '||'&'||' collected at the sites for this study. Test, not at each working hour but at 14 : 00 when the almost all of the workers think the most tired, resulting from the questionaires, also when it is shown on the research report has been performed and compared for main kinds of works : form '||'&'||' re-bar work. Tests were performed with both left SE rightand of the workers simultaneously in construction site using Rand Dynamometer(Model 78010, Lafayette Instrument Co., Indiana, U.S.A) by reading grip strength on the gauge while they are pulling, and then by interviewing on their ages, works, experiences and etc., directly. The above tests have been performed for the dates of 15th march-26th May '95 with consideration of site condition. And even if various factors of ambient temperature on the testing date, working condition, individual worker's habit and worker's condition of the previous ate are concerned with the study. Those are considered as constants in this study. Samples are formwork 53, rebar 62, electrician 5, plumber 4, welding 1 from D construction Co., Ltd, ; formwork 12, re-bar 5, electrician 2, from S construction Co., Ltd, , formwork 78, re-bar 18, plumber 31, electrician 13, labor 48, plumber 31, plasterer 15, concrete placer 6, water proof worker 3, maisony 5 from B construction Co., Ltd. As In the previously mentioned, main aspect to be investigated in this study will be from '||'&'||' re-bar work because grip strength will be directly applied to these two kinds of works ; form '||'&'||' re-bar work, eventhough there are total 405 samples taken. It is thought that a frequency of accident occurrence will be mainly two work postures "looking up '||'&'||' looking down" to be mainly sorted, but this factor is not clarified in this study because It will be needed a lot of work more. Tests has been done at possible large scale of horizontally work-extended sites within one hour in order to prevent or decrease errors '||'&'||' discrepancies from time lag of the test. Additionally, the statistical package computer program SPSS PC+has been used for the study.

  • PDF

Effects of Glycogen Supercompensation in Fast and Slow Muscles on Maximal Running Time of Endurance-trained Rats (단련한 흰쥐의 속근 및 지근에 Glycogen 과저장이 운동 지구력에 미치는 영향)

  • Yeoun, Dong-Soo;Hwang, Soo-Kwan;Kim, In-Sook;Ko, Seong-Kyeong;Nam, Taick-Sang;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.22 no.1
    • /
    • pp.63-77
    • /
    • 1988
  • This study was carried out to investigate relationships between maximal running time (MRT) and glycogen supercompensation in fast twitch white fibers (white vastus, WV), fast twitch red fibers (red vastus, RV) and slow twitch red fibers (soleus muscle, SM) of endurance-trained rats. Male rats of a Sprague-Dawley strain were divided into the trained groups and untrained groups. Untrained groups were acquired to run on the treadmill 10 minutes for 3 days and remained rest and maintained with mixed diet for 4 weeks. For last 10 days of resting period, the untrained rats were divided into 3 groups i.e. mixed diet (untrained control), high and low carbohydrate (CHO) diet groups. And each group was subdivided into 2 groups, one group was tested for the MRT and the other was sacrificed to measure the blood glucose, blood lactate, glycogen contents of liver and muscles. The experimental groups were trained on treadmill by a modified method of Constable et al. (1984) maintained with mixed diet for 4 weeks. After measurement of MRT of this group, they were also divided into high and low CHO groups and fed with these diet for 2 days and MRT of each group was measured again to see the effect of high or low CHO feeding on the MRT. Each group was maintained with the same diet for next 2 days during which some of the rats were sacrificed at given time intervals for the measurements of blood glucose and lactate, liver and the muscles glycogen. The results were summarized as follows; 1) In the untrained group, there were no significant differences between subgroups in MRT, glycogen conent of SM, RV and WV. But blood glucose concentration and glycogen content of liver of low CHO group were significantly lower than those of mixed diet group. 2) The MRT and glycogen content of SM, RV and WV of trained mixed diet group were significantly increased compared to those of untrained mixed diet group, but there was no significant difference in glycogen content of liver. 3) MRT of trained mixed, high CHO and low CHO groups were $137{\pm}9.8,\;176{\pm}9.8\;and\;129{\pm}7.3\;min$ respectively with the significant difference between them. 4) There were no differences in blood lactate concentrations between the trained high and low CHO groups immediately after maximal running and during recovery period. 5) Glycogen contents in RV and SM of trained high CHO group were significantly increased, and glycogen contents in RV, WV and liver of trained low CHO group were significantly decreased compared to those of trained mixed diet group. 6) Immediately after maximal running, the blood glucose concentrations of trained high CHO and low CHO groups were $73{\pm}4.0\;and\;67{\pm}6.9mg%$ respecitively. The blood glucose of the trained high CHO group was fully recovered within one hour by feeding. But blood glucose concentration of low CHO group was slowly recovered up to $114{\pm}4.1mg%$ after two hours of feeding and maintained. Those values were still significantly lower than that of trained mixed diet group. The synthetic rates of glycogen in liver and muscles during the recovery period followed the similar time course of the blood glucose recoveries in each group. These results suggest that an increase in MRT of trained high CHO group was attributed to the glycogen supercompensation in slow twitch muscle fibers. And a decrease in MRT of trained low CHO may be due to decreased glycogen contents of liver and muscles. The results also suggest that glycogen supercompensation was more evident in slow twitch red fibers of endurance-trained rats and blood glucose is one of the limiting factors of glycogen synthesis.

  • PDF

EFFECT OF FILM THICKNESS OF RESIN CEMENT ON BONDING EFFICIENCY IN INDIRECT COMPOSITE RESTORATION (레진 시멘트의 film thickness가 간접 복합 레진 수복물의 접착 효율에 미치는 영향에 관한 연구)

  • Lee, Sang-Hyuck;Choi, Gi-Woon;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.69-79
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of film thickness of various resin cements on bonding efficiency in indirect composite restoration by measurement of microtensile bond strength, polymerization shrinkage, flexural strength and modulus, fractographic FE-SEM analysis. Experimental groups were divided according to film thickness (< $50\;{\mu}m$-control, $50\;{\mu}m$-T50, $100\;{\mu}m$-T100, $150\;{\mu}m$-T150) using composite- based resin cements (Variolink II, Duo-Link) and adhesive-based resin cements (Panavia F, Rely X Unicem). The data was analyzed using ANOVA and Duncan's multiple comparison test (p < 0.05). The results were as follows ; 1. Variolink II showed higher microtensile bond strength than that of adhesive-based resin cements in all film thickness (p < 0.05) but Duo-Link did not show significant difference except control group (p > 0.05). 2. Microtensile bond strength of composite-based resin cements were decreased significantly according to increasing film thickness (p < 0.05) but adhesive-based resin cements did not show significant difference among film thickness (p > 0.05). 3. Panavia F showed significantly lower polymerization shrinkage than other resin cements (p < 0.05). 4. Composite-based resin cements showed significantly higher flexural strength and modulus than adhesive-based resin cements (p < 0.05). 5. FE-SEM examination showed uniform adhesive layer and well developed resin tags in composite-based resin cements but unclear adhesive layer and poorly developed resin tags in adhesive-based resin cements. In debonded surface examination, composite-based resin cements showed mixed failures but adhesive-based resin cements showed adhesive failures.

The Effects of LBS Information Filtering on Users' Perceived Uncertainty and Information Search Behavior (위치기반 서비스를 통한 정보 필터링이 사용자의 불확실성과 정보탐색 행동에 미치는 영향)

  • Zhai, Xiaolin;Im, Il
    • Asia pacific journal of information systems
    • /
    • v.24 no.4
    • /
    • pp.493-513
    • /
    • 2014
  • With the development of related technologies, Location-Based Services (LBS) are growing fast and being used in many ways. Past LBS studies have focused on adoption of LBS because of the fact that LBS users have privacy concerns regarding revealing their location information. Meanwhile, the number of LBS users and revenues from LBS are growing rapidly because users can get some benefits by revealing their location information. Little research has been done on how LBS affects consumers' information search behavior in product purchase. The purpose of this paper is examining the effect of LBS information filtering on buyers' uncertainty and their information search behavior. When consumers purchase a product, they try to reduce uncertainty by searching information. Generally, there are two types of uncertainties - knowledge uncertainty and choice uncertainty. Knowledge uncertainty refers to the lack of information on what kinds of alternatives are available in the market and/or their important attributes. Therefore, consumers having knowledge uncertainty will have difficulties in identifying what alternatives exist in the market to fulfil their needs. Choice uncertainty refers to the lack of information about consumers' own preferences and which alternative will fit in their needs. Therefore, consumers with choice uncertainty have difficulties selecting best product among available alternatives.. According to economics of information theory, consumers narrow the scope of information search when knowledge uncertainty is high. It is because consumers' information search cost is high when their knowledge uncertainty is high. If people do not know available alternatives and their attributes, it takes time and cognitive efforts for them to acquire information about available alternatives. Therefore, they will reduce search breadth. For people with high knowledge uncertainty, the information about products and their attributes is new and of high value for them. Therefore, they will conduct searches more in-depth because they have incentive to acquire more information. When people have high choice uncertainty, people tend to search information about more alternatives. It is because increased search breadth will improve their chances to find better alternative for them. On the other hand, since human's cognitive capacity is limited, the increased search breadth (more alternatives) will reduce the depth of information search for each alternative. Consumers with high choice uncertainty will spend less time and effort for each alternative because considering more alternatives will increase their utility. LBS provides users with the capability to screen alternatives based on the distance from them, which reduces information search costs. Therefore, it is expected that LBS will help users consider more alternatives even when they have high knowledge uncertainty. LBS provides distance information, which helps users choose alternatives appropriate for them. Therefore, users will perceive lower choice uncertainty when they use LBS. In order to test the hypotheses, we selected 80 students and assigned them to one of the two experiment groups. One group was asked to use LBS to search surrounding restaurants and the other group was asked to not use LBS to search nearby restaurants. The experimental tasks and measures items were validated in a pilot experiment. The final measurement items are shown in Appendix A. Each subject was asked to read one of the two scenarios - with or without LBS - and use a smartphone application to pick a restaurant. All behaviors on smartphone were recorded using a recording application. Search breadth was measured by the number of restaurants clicked by each subject. Search depths was measured by two metrics - the average number of sub-level pages each subject visited and the average time spent on each restaurant. The hypotheses were tested using SPSS and PLS. The results show that knowledge uncertainty reduces search breadth (H1a). However, there was no significant correlation between knowledge uncertainty and search depth (H1b). Choice uncertainty significantly reduces search depth (H2b), but no significant relationship was found between choice uncertainty and search breadth (H2a). LBS information filtering significantly reduces the buyers' choice uncertainty (H4) and reduces the negative relationship between knowledge uncertainty and search breadth (H3). This research provides some important implications for service providers. Service providers should use different strategies based on their service properties. For those service providers who are not well-known to consumers (high knowledge uncertainty) should encourage their customers to use LBS. This is because LBS would increase buyers' consideration sets when the knowledge uncertainty is high. Therefore, less known services have chances to be included in consumers' consideration sets with LBS. On the other hand, LBS information filtering decrease choice uncertainty and the near service providers are more likely to be selected than without LBS. Hence, service providers should analyze geographically approximate competitors' strength and try to reduce the gap so that they can have chances to be included in the consideration set.