• 제목/요약/키워드: Experimental Values

검색결과 6,443건 처리시간 0.034초

교합안정장치의 장착이 저작근 활성도에 끼치는 영향에 관한 연구 (A Study on the Effects of Occlusal Stabilization Splint on Electromyographic Activity)

  • Min Shin;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • 제14권1호
    • /
    • pp.67-80
    • /
    • 1989
  • The author studied the changes of muscle activity with Bioelectric processor Model EM2(Myotronics Corp., USA) before and after occlusal stabilization splint therapy. For this study, 15 temporomandibular disorders patients and 15 students without any temporomandibular disorders symptoms were selected, for experimental group and control group, respectively. Experimental group were treated with occlusal stabilization splint and checked about electromyographic activity before and after therapy. Electromyographic levels were measured in both groups at the following mandibular position, i.e., physiologic rest, tapping, light biting, hard open without pain, open with pain, right excursion and ipsilateral biting, left excursion and ipsilateral biting, protrusion, protrusive biting, edge biting and physiologic rest after movement. The obtained results were as follows : 1. In experimental group, post-treatment mean values of muscle activity were lower than pretreatment values. 2. In general, the pre-treatment mean values of muscle activity in experimental group were higher than those of control group. 3. In experimental group, no statistically significant difference appeared between affected and unaffected side. 4. The mean value of muscle activity in physiologic rest position after each movement check was lower than that before each movement check.

  • PDF

개에서 Halothane 반복마취가 혈액학 및 혈액화학치에 미치는 영향 (Effects of Repeated Halothane Anesthesia on Canine Hematologic and Hematochemical values)

  • 이정국;권해병
    • 한국임상수의학회지
    • /
    • 제11권1호
    • /
    • pp.407-417
    • /
    • 1994
  • Present experiments were undertaken for the purpose of clarifying the effect of repeated halothane anesthesia on the liver and kidney function. Nine mongrel dogs were divided into three groups. The group one dogs were anesthesized once(control group) and the other two groups twice and trice respectively on 10th day of previous anesthesia experimental groups. Hematological examinations and blood chemical assays were undertaken during the period from one hour to 10 days after the anesthesia. From these experiments fellowing results were obtained; 1. No significant changes of erythrocyte count were recognized in both the control and experimental groups after the halothane anesthesia. 2. The total leukocyte counts of experimental groups showed significant decrease on one hour and subsequent increases after the anesthesia. 3. No significant changes were observed in SGOT, SGPT, ALP, BUN and serum glucose values in both the control and experimental groups. 4. The total serum protein values showed a tendency to decrease on the first hour of halothane anesthesia in both the control and experimental groups. From these results it may be concluded that the repeated halothane anesthesia done 10th day of previous anesthesia do not affect the liver and kidney function in dogs.

  • PDF

Character Classification with Triangular Distribution

  • Yoo, Suk Won
    • International Journal of Advanced Culture Technology
    • /
    • 제7권2호
    • /
    • pp.209-217
    • /
    • 2019
  • Due to the development of artificial intelligence and image recognition technology that play important roles in the field of 4th industry, office automation systems and unmanned automation systems are rapidly spreading in human society. The proposed algorithm first finds the variances of the differences between the tile values constituting the learning characters and the experimental character and then recognizes the experimental character according to the distribution of the three learning characters with the smallest variances. In more detail, for 100 learning data characters and 10 experimental data characters, each character is defined as the number of black pixels belonging to 15 tile areas. For each character constituting the experimental data, the variance of the differences of the tile values of 100 learning data characters is obtained and then arranged in the ascending order. After that, three learning data characters with the minimum variance values are selected, and the final recognition result for the given experimental character is selected according to the distribution of these character types. Moreover, we compare the recognition result with the result made by a neural network of basic structure. It is confirmed that satisfactory recognition results are obtained through the processes that subdivide the learning characters and experiment characters into tile sizes and then select the recognition result using variances.

임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향 (INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY)

  • 오갑용;박성화;김석규
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.

변형 제누아즈법으로 만든 쌀가루 첨가 스폰지 케이크의 품질 특성 (Quality Characteristics of Sponge Cakes with Added Rice Flour Produced by Modified Genoise Method)

  • 박희옥;장재선;손춘영
    • 한국식품영양학회지
    • /
    • 제23권4호
    • /
    • pp.607-614
    • /
    • 2010
  • The aim of this study was to investigate the quality characteristics of sponge cakes with added rice flour produced by a modified genoise method to prevent volume reduction. A control group and experimental group I were prepared by the genoise method and experimental groups II, III, and IV were produced by a modified genoise method in which they were mixed with wheat flour and water to a make paste to form gluten for 3, 6, and 9 minutes, respectively. One third of the wheat flour in all experimental groups was replaced by rice flour. The control and experimental groups were compared in terms of quality characteristics, including batter specific gravity, volume, color, textural characteristics, and sensory qualities, to determine the optimal pasting time for wheat flour in the formulation. The specific gravity of the experimental groups was higher than that of the control and decreased with increasing wheat flour pasting time. The volume of experimental group I was lower than that of the control group, and the volume values of experimental groups III and IV, made by the modified genoise method, were higher than that of the control group. $dL^*$ and $db^*$values for the crust and inside of the cake were lower in the experimental groups than in the control. The $dL^*$ value, indicating brightness, increased as pasting time increased. The hardness values of experimental groups I and IV were higher than that of the control whereas experimental groups II and III had lower hardness values. Chewiness was higher in the control group, as well as experimental groups I and IV than in the experimental groups II and III. The gumminess of experimental group IV was highest. Cohesiveness decreased by adding rice flour to the sponge cake. Sensory attributes of cell uniformity, tenderness, moistness, taste, and overall acceptability had the highest scores in experimental group III. Based on these results, we conclude that the quality of sponge cake containing one third of the wheat flour replaced by rice flour is best with 6 minutes pasting of the wheat flour to form gluten.

Ab Initio Studies of Hydrogen Bihalide Anions: Anharmonic Frequencies and Hydrogen-Bond Energies

  • Cheong, Byeong-Seo
    • 대한화학회지
    • /
    • 제63권4호
    • /
    • pp.237-245
    • /
    • 2019
  • Hydrogen bihalide anions, $XHX^-$ (X = F, Cl, and Br) have been studied by high level ab initio methods to determine the molecular structure, vibrational frequencies, and energetics of the anions. All bihalide anions are found to be of linear and symmetric structures, and the calculated bond lengths are consistent with experimental data. The harmonic frequencies exhibit large deviations from the experimental frequencies, suggesting the vibrations of these anions are very anharmonic. Two different approaches, the VSCF and VPT2 methods, are employed to calculate the anharmonic frequencies, and the results are compared with the experimental frequencies. While the ${\nu}_1$ and ${\nu}_2$ frequencies are in reasonable agreement with the experimental values, the ${\nu}_3$ and ${\nu}_1+{\nu}_3$ frequencies still exhibit large deviations. The hydrogen-bond energies and enthalpies are calculated at various levels including the W1BD and G4 composite methods. The hydrogen-bond enthalpies calculated are in good agreement with the experimental values.

수송 기술에 적합한 학습용 풍동의 힘 측정 장치 개발 (Development of Force Measuring Device in Learning Wind Tunnel Used for Transportation Technology Class)

  • 최준섭;이성구
    • 대한공업교육학회지
    • /
    • 제32권1호
    • /
    • pp.117-133
    • /
    • 2007
  • 이 연구는 중등학교 학생들에게 비행의 원리를 이해하고 항공 기술 분야에 흥미를 가질 수 있도록 하기 위해 학교 현장에 적용 가능한 교수-학습 자료인 학습용 풍동의 힘 측정 장치를 개발하였다. 연구의 내용은 학습용 풍동의 힘 측정 장치 개발과 실험으로 이루어져 있다. 이 연구에서 얻은 주요 결과를 정리하면 다음과 같다. 공과대학 기계계열 학과나 항공연구소 등에서 사용하는 고가의 Load cell을 이용한 장치 대신에 지렛대 원리를 활용한 간단한 구조이다. 종합된 하나의 장치로 양력, 항력 및 유체 저항 비교 실험이 가능하다. 에어포일 받음각에 따른 양력 계수는 실험값과 이론값이 전체적으로 비슷한 경향성을 갖으며, 실속 현상은 실험값이 이론값보다 더 큰 받음각에서 나타났다. 에어포일 받음각에 따른 항력 계수는 실험값과 이론값이 전체적으로 비슷한 경향성을 갖으며, 실험값은 이론값에 비해 항력 계수의 증가 비율이 완만하게 증가하였다.

Statistical reference values for control performance assessment of seismic shake table testing

  • Chen, Pei-Ching;Kek, Meng-Kwee;Hu, Yu-Wei;Lai, Chin-Ta
    • Earthquakes and Structures
    • /
    • 제15권6호
    • /
    • pp.595-603
    • /
    • 2018
  • Shake table testing has been regarded as one of the most effective experimental approaches to evaluate seismic response of structural systems subjected to earthquakes. However, reproducing a prescribed acceleration time history precisely over the frequency of interest is challenging because shake table test systems are eventually nonlinear by nature. In addition, interaction between the table and specimen could affect the control accuracy of shake table testing significantly. Various novel control algorithms have been proposed to improve the control accuracy of shake table testing; however, reference values for control performance assessment remain rare. In this study, reference values for control performance assessment of shake table testing are specified based on the statistical analyses of 1,209 experimental data provided by the Seismic Simulator Laboratory of National Center for Research on Earthquake Engineering in Taiwan. Three individual reference values are considered for the assessment including the root-mean-square error of the achieved acceleration time history; the percentage of the spectral acceleration that exceeds the determined tolerance range over the frequency of interest; and the error-ratio of the achieved peak ground acceleration. Quartiles of the real experimental data in terms of the three objective variables are obtained, providing users with solid and simple references to evaluate the control performance of shake table testing. Finally, a set of experimental data of a newly developed control framework implementation for uni-axial shake tables are used as an application example to demonstrate the significant improvement of control accuracy according to the reference values provided in this study.

황련 황금 황백이 백서의 GASTRIN 및 UROPEPSIN 분비에 미치는 영향 (Effects on the secretion of Gastrin and Uropepsin of rats treated with Coptidis Rhizoma, Scutellariae Radix and Phellodendri Cortex)

  • 김성욱;김병우
    • 대한한방내과학회지
    • /
    • 제22권4호
    • /
    • pp.703-707
    • /
    • 2001
  • Each decoction of Coptidis Rhizoma, Scutellariae Radix and Phellodendri Cortex was orally administrated to the rates. And the effects on the Gastrin and Uropepsin secretions were observed. The results were as follows: 1. The effects on the secretio of Gastrin in the experimental groups administrered each with Coptidis Rhizoma and Scutellariae Radix comparing with the normal group, showed signficant values P<0.05, P<0.02, P<0.01 and P<0.001 separately. However the group medicated with Phellodendri Cortex showed significant values only 30 minutes after the administration. 2. Uropepsion level in the experimental group administered each with Coptidis Rhizoma and Phellodendri Cortex, comparing with the normal group, showed highly significant statistic values (P<0.001). Another experimental group medicated with Scutellariae Radix showed significantly statistical values (P<0.001) 240 minutes after the administration. 3. According to the above mentioned results it was onculuded tat the secretion of Gastrin in plasma and Uropepsin content of urine in albino rats treated with Coptiodis Rhizoma decoction were remarkaby increased as comparing with Scutellariae Radix and Phellodendri Cortex decoction.

  • PDF

Measurement of $\beta_{eff}$ in the Fast Critical Assembly BFS and Validation of a $\beta_{eff}$ Computation Code, BETA-K

  • Kim, Taek-Kyum;Kim, Young-Il;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.401-407
    • /
    • 1999
  • We have performed two experiments in the fast critical assembly BFS to measure the effective delayed neutron fraction $\beta$$_{eff}$ values and compared the results to validate the $\beta$$_{eff}$ computation code, BETA-K. Measurements of $\beta$$_{eff}$ were carried out in a metallic plutonium core and a metallic uranium core with Cf$^{252}$ source pseudo-reactivity method. Fission integrals and correction factors, which were used to obtain the experimental $\beta$$_{eff}$ values, were calculated by using the LMR core design computation code system of KAERI. BETA-K has been developed consistently with the hexagonal Nodal Expansion Method (NEM) and it used delayed neutron data of ENDF/B-VI. By comparing the computed $\beta$$_{eff}$ values with the measured ones, we found that the results from BETA-K agreed with the experimental values within the experimental error bound.ror bound.

  • PDF