• Title/Summary/Keyword: Existing subway

Search Result 185, Processing Time 0.026 seconds

A Study on the Varistor Maintenance program in urban rail chopper type subway train (도시철도 쵸파형 전동차 배리스터(varistor) 유지보수 방안 연구)

  • Woo, Jong-Hyuk;Lee, Jong-In;Lee, Yong-Gi;Song, Jeong-Hun
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1647-1653
    • /
    • 2011
  • In the case of an urban rail chopper type subway train, varistors have been installed for protecting usual electronic equipments, semiconductor devices(diodes, transistors, thyrister, etc.) communications, measuring, control device and absorbing opening & closing surge of electromagnetic valve. These varistors were steadily reduced dielectric strength as becoming superannuated. Thus there is a problem that reacts more sensitive at the same surge in the general control operation. On existing maintenance, there is not specific standard to replace superannuated varistor. So when maintaining chopper type subway train, all varistors or old varistors that workers checked a discoloration & crack with the naked eye and noticed degradation smell by deterioration are replaced. This study suggests detail standards for judgement that varistors are good or bad chopper type subway train, and it draw a efficient maintenance which efficient maintenance can check more easy the degradation properties variation.

  • PDF

Integrated Ground-Underground Spatial Network for Urban Spatial Analysis (도시 공간분석을 위한 지상·지하 공간 네트워크)

  • Piao, Gensong;Choi, Jaepil
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.4
    • /
    • pp.69-76
    • /
    • 2018
  • The purpose of this study is to propose and verify a spatial network construction method that integrated roads and subway lines to improve the predictability of the urban spatial analysis model. The existing axial map for urban spatial analysis did not reflect the subway line that serves as an important moving space in modern cities. To improve this axial map, proposed a Ground-Underground Spatial Network by integrating the underground spatial network with the axial map. As a result of the integration analysis, the Ground-Underground Spatial Network(GUSN) were similar to the movement frequency. Correlation of GUSN was 0.723, which showed higher explanatory power than correlation coefficient of 0.575 in axial map. The result of this study is expected to be a theoretical basis for constructing spatial network in urban space analysis with subway.

Service Satisfaction Evaluation of Each Travel Section in Seoul's Subway Junctions (서울 도시철도 환승역의 통행구간별 서비스만족도 평가)

  • O, Mi-Yeong;Kim, Jang-Uk;Park, Dong-Ju;Son, Ui-Yeong;Lee, Su-Beom
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.4
    • /
    • pp.85-93
    • /
    • 2010
  • Unlike the existing subway service evaluation system, service evaluation indices by travel section in 26 subway stations were developed and appraised. Travel sections were classified into (1) subway station approach, (2) from entrance to platform, (3) platform, and (4) passageway for transfer, after which weights by travel section and by service evaluation index were estimated using analytic hierarchy process (AHP) by transportation experts. Subway service satisfaction data was gathered from 2000 passengers at the 26 subway stations. The results showed that the weights of (1) subway station approach and (4) passageway for transfer were highest and the weights by travel sections were different if kinds of services were the same. Comfort on the platform, crowdedness in the passageway for transfer, and transfer information from entrance to platform were highest in order in terms of satisfaction. Meanwhile, the results of the IPA showed that services in the passageway for transfer were high in terms of weights but were relatively low in terms of satisfaction. Therefore the services in passages for transfer needed to be reformed preferentially.

Barrier-Free Subway Service System Scenario : Comparison Between Korea and China (한국과 중국의 비교를 통한 무장애 지하철 서비스시스템 시나리오 제안)

  • Jia-Xing Long;Sung-Pil Lee
    • Journal of Service Research and Studies
    • /
    • v.11 no.3
    • /
    • pp.55-74
    • /
    • 2021
  • In the global era, the tourism industry is a major profitable business, and the state and local governments are making various efforts to provide quality tourism experiences. The purpose of this study in a variety of tourism contents is to study barrier-free subway services in line with the global era, and to expand from the existing rapid, safe, and ordered transportation to the provision of high-quality comfort and all-round service experiences. This study compared and analyzed the subway service systems of Korea, China and both countries through the service design method, and presented a barrier-free subway service system to improve the user's satisfaction with the subway service system by improving the user's service experience. As a result, research results showed that 20 attractive quality attributes in 17 fields, such as convenience facilities, language issues, security equipment, and riding environment, play an important role in improving the quality and experience of subway services. In addition, through the construction of a Service Spatial Scenario, an optimized subway service system can be visualized to help understand this so that it can be used as a reference for creating a strategic application.

Stability Analysis of Existing Tunnel in Stratified Sedimentary Rocks Subjected to Bridge Pier Load (퇴적암 지역에서의 교각 기초 하중을 받는 기존터널의 안정성에 대한 해석적 고찰)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.8 no.2
    • /
    • pp.153-161
    • /
    • 1998
  • An anisotropic characteristics of stratified sedimentary rocks should be considered in the design of tunnel. The second line of Taegu subway is under construction through the sedimentary rocks which is stratified by alternation of shale and sandstone, and Tongsoe over bridge road is planned to be constructed along the subway line. Thus the subway twin tunnels will be subjected by the bridge load of 76.2 MN per pier that will be placed in between the twin tunnels of the subway line. A numerical analysis is carried out for the stability of the twin tunnel, and the result shows that the maximum principal stress of surrounding ground is increased by 5∼6 MPa and the additional displacement of concrete lining is reached up to 8∼10mm due to the external bridge load. For the safety operation of the subway, reinforcement of the tunnel structure is highly recommended.

  • PDF

Subway Station's Seating Capacity of Temporary Evacuees from Disastrous Situation through Analyzing the Number of Toilets (위생기구(변기) 수 분석을 통한 지하철역의 임시 대피인원 수용 능력 산정)

  • Sohn, Byonghu;Hwang, Eun-Kyoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.418-426
    • /
    • 2013
  • With advantages of open spaces and existing HVAC facilities, subway station, if unexpected disastrous situation happens on the ground, can be used as a temporary safe place for evacuees. The main objective of this study is to establish a guideline on estimating evacuation capacity of the subway station and evaluating levels of service of evacuation for officials to control the situation. This guideline includes available spaces of the station, capacity of sanitary fixtures, and total number of passengers, etc. In this paper, we first analyzed the number of passengers of SMRT (Line 5~Line 8) during AM peak hour and then evaluated the number of passengers using toilets at that time. In addition, we calculated the seating capacity of subway stations on SMRT using the difference between the actual number of toilets and the estimated number of ones from the occupancy time of each toilet.

Study on Air Washer using Underground Water in the Subway Stations (지하철 역사 지하수를 이용한 에어와셔에 관한 연구)

  • Kim, Dong-Gyu;Kim, Hoe-Youl;Chung, Yong-Hyun;Kim, Jong-Ryul;Kum, Jong-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.22 no.4
    • /
    • pp.604-610
    • /
    • 2010
  • Busan subway transportation system has been established a key role in the society last 20 years. However many people are suffering from hot and humid environment at subway station and platform due to deteriorated ventilation system as well as insufficient air conditioning system in existing stations and platforms. As a result, these systems require revitalization. There is about 5400tons of low temperature underground water is generated from subway stations every day. By using this method and air washer we are trying to lower the temperature. Air washer is commonly used for removing humidity but in this experiment it will be used as air precooling. This research offers result of experiment using air washer system to lower the temperature in large spaces like subway station. The experiment result has shown when L/G was the same, at condition which water spray temperature at $18^{\circ}C$ resulting inlet and outlet temperature difference larger. Also, in the same water spray temperature conditions, larger L/G condition showed a greater temperature difference. LCC evaluation of both system were shown that air washer system of using underground water will save 53% of the initial cost than refrigeration system, and save 75% of operating cost.

Structure stability study for existing subway tunnel segment of Seoul-Busan high-speed railroad (Daegu - Busan) construction (경부고속철도(대구-부산) 도심통과 노반신설 공사중 기존 지하철 터널구간의 구조적 안정성 검토)

  • Kong, Byung-Seung;Kim, Min-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1752-1759
    • /
    • 2007
  • In the new Seoul-Busan high speed railroad construction specially city center passage roadbed establishment is recommended the staibility for the existing subway tunnel segments of Busan subway line No. 1 and No.2. regarding the appearance condition, a quality condition and the durability of the objective facility site exact inspection, and it evaluates the numerical analysis which uses MIDAS GTS it leads and there is the objective of the place where the stability of the objective facility and this tunnel it investigates. To immediacy of the on-the-spot inspection result whole facility it is a condition where the reinforcement which is simple not to be hindrance is necessary, 2nd Line case it is a condition which transfer is good but the general defect and the damage which occur from the tunnel of NATM type were confirmed part. While roadbed establishment constructing that the continuous maintenance is necessary, it is judged. The result of 1st, 2nd Line maximum sinkage, unequal sinkage and the lining stress of numerical analysis are within permission and the damage degree is appearing with the fact that the degree it will can disregard it is slight. But it enforces necessary Pre-grouting in order to minimize an actual tunnel face conduct and when the tunnel is excavated it is judged with the fact that necessary to minimize the outflow possibility.

  • PDF

On the Supplementary Study on DSM-Based Interface Requirements through Analysis of the Operation Scenario of the Urban Subway Logistics System

  • Hwang, Sunwoo;Kim, Joouk;Park, Jaemin;Lee, Sangmin;Kim, Youngmin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.152-161
    • /
    • 2022
  • Recently, it is recognized as a high-cost and inefficient logistics system that increases traffic congestion and environmental problems due to an increase in traffic volume due to the activation of the online market. In order to solve inefficient problems such as unavoidable traffic congestion and environmental problems caused by the increase in traffic volume, it is necessary to develop a freight transport system technology using the existing urban railway infrastructure and freight-only urban railway. The urban subway logistics system is a logistics system that requires a combination of various technologies to solve the nationwide demand for urban logistics and road traffic problems. This paper recognized the existing traffic congestion and environmental pollution of road traffic as problems, and supplemented the contact point requirements presented above by identifying the sub-systems constituting the target system and supplementary points for each part-level contact point. In this study, as a complex system operated for one purpose by grafting various technologies, a plan is required to secure the reliability and safety of operation from various viewpoints. The results of this study can contribute to the initial configuration and basic data to solve the interface bottleneck of the urban subway logistics system to be promoted in the future.

The economical efficiency analysis of LED illuminator application at subway station (지하 역사 LED조명기구의 적용에 대한 경제성 분석)

  • Kim, Youn-Sik;Sim, Jae-Suk;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1868-1872
    • /
    • 2010
  • The LED illuminator has merits that it has low power consumption, long life and emits low Co2 gas. As it has many merits in comparison with existing illuminator it is a realistic alternative. but its possession in illuminator market shows slow increasement unexpectedly. Because its price is very high only low power consumption can not keep pace with economical efficiency. In this paper I analyzed economical efficiency about LED illuminator when it is applied at subway station.

  • PDF