Browse > Article

Study on Air Washer using Underground Water in the Subway Stations  

Kim, Dong-Gyu (Pukyung National University)
Kim, Hoe-Youl (GE Engineering)
Chung, Yong-Hyun (Pukyung National University)
Kim, Jong-Ryul (Tongmyong University)
Kum, Jong-Soo (Pukyung National University)
Publication Information
Journal of Fisheries and Marine Sciences Education / v.22, no.4, 2010 , pp. 604-610 More about this Journal
Abstract
Busan subway transportation system has been established a key role in the society last 20 years. However many people are suffering from hot and humid environment at subway station and platform due to deteriorated ventilation system as well as insufficient air conditioning system in existing stations and platforms. As a result, these systems require revitalization. There is about 5400tons of low temperature underground water is generated from subway stations every day. By using this method and air washer we are trying to lower the temperature. Air washer is commonly used for removing humidity but in this experiment it will be used as air precooling. This research offers result of experiment using air washer system to lower the temperature in large spaces like subway station. The experiment result has shown when L/G was the same, at condition which water spray temperature at $18^{\circ}C$ resulting inlet and outlet temperature difference larger. Also, in the same water spray temperature conditions, larger L/G condition showed a greater temperature difference. LCC evaluation of both system were shown that air washer system of using underground water will save 53% of the initial cost than refrigeration system, and save 75% of operating cost.
Keywords
Air washer; Precooling; Underground water; L/G; LCC;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 김회률(2010). 자연에너지를 활용한 지하역사 승강장 열환경 개선 방안에 관한 연구, 부경대학교 학위논문.
2 김효경 역(2005). 공기조화 개정 3판, 동명사, 247-261.
3 부산지역환경센터(2009). 부산지하철 1호선 승강장 열환경 개선방안에 관한 연구
4 유경훈(2006). 열회수식 에어와셔 시스템 선행 연구, 한국생산기술연구원.
5 정순성(1999). HVAC시스템의 의사결정을 위한 LCC영향도 다이어그램 개발에 관한 연구, 동아대학교 학위논문.
6 김회률 외 4인(2009). 자연에너지 활용을 위한 지하철 승강장 열환경에 관한 연구, 수산해양교육연구, 269-277.
7 김회률 외 4인(2009). 자연에너지를 활용한 지하철 승강장 리모델링에 관한 연구, 대한건축학회 지회 논문집, 729-732.
8 김태형 외 4인(2008). 분무수 온도 변화에 따른 에어와셔의 온습도 특성에 관한 실험적 연구, 대한설비공학회 동계학술발표대회 논문집, 446-451.
9 김회률 외 5인(2010). 지하수를 이용한 도시철도 지하 승강장 열환경 개선 설계 사례, 대한설비공학회 하계학술발표대회 논문집, 264
10 건설교통부(2002). 대형시설물 등의 유출지하수자원 활용방안 연구.
11 김호성 외 4인(2004). 지하철 역사 지하수를 이용한 히트펌프시스템 타당성 연구, 대한설비공학회 하계학술발표대회 논문집, 1369-1374.
12 김회률 외 4인(2009). 외기 예냉설비를 활용한 지하철 승강장 환기설비 개선에 관한 연구, 한국생활환경학회지, 275-279.