• 제목/요약/키워드: Exciter test

검색결과 72건 처리시간 0.04초

자력을 이용한 비접촉식 박판 가진장치 개발에 관한 연구 (Study on the Development of Noncontact Vibration Exciter for Thin Plates Using Magnetism)

  • 허관도;손인수
    • 한국소음진동공학회논문집
    • /
    • 제26권1호
    • /
    • pp.104-109
    • /
    • 2016
  • The noncontact vibration exciter system using the electro-magnet for a thin plate is studied in this paper. Based on the Euler-Bernoulli beam theory, the equation of motion of thin plate is derived. The main purpose of this experiment is to match the input-frequency and response frequency of thin plate. The test equipment is configured to vibrate on both sides of the thin plate using the electro-magnet. Two frequencies(input frequency and response frequency) in our experiments show very good agreement. This study results will contribute to basic investigate of an alternative air-knife system for the steel industry.

VSB 기술의 분석과 시각적 이해 (VSB Visualization)

  • 이동두
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 1999년도 디지털 방송기술 워크샵
    • /
    • pp.117-138
    • /
    • 1999
  • .8-VSB Modulator for Digital Television . ERRI'S ATSC VSB EXCITER . Pre-Corrector . Field Test . Lab Test

  • PDF

발전기 여자기시스템 주제어전원공급장치 국산화 개발 (The Development of EPSM(Exciter Power Supply Module) Localization in Generator Exciter(EX2100) System)

  • 이기선;박정철;추순남
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.101-107
    • /
    • 2016
  • The main target in this paper is the localization of VME Type EPSM in Generator Exciter(EX2100) System. Developed EPSM has the compatibility with the existing product in the structure and shape and electrical feature and so on, but it has a much improved capacity and reliability in comparison with origin company product. this paper, to improve these functions, put emphasis on protection, monitoring, power capacity increase(over 120%), an enlarged scale of input voltage supply, AC/DC dual voltage use and so on. After manufacturing product localization, it was carried out several tests for the performance and reliability verification of developed product. These tests were performed in Authorized Inspection Agency(KTL) and field application test and maker self-test were additionally performed. Finally, the results of all tests were "success".

수직발사 유도탄의 진동시험에서 유도탄 장착방향의 영향에 대한 연구 (Study on the Effects of the Mounting Direction of Vertically-launched Missiles in Vibration Tests)

  • 이호준;김기언
    • 한국소음진동공학회논문집
    • /
    • 제23권3호
    • /
    • pp.218-225
    • /
    • 2013
  • Vertically-launched missiles are supported as erected vertically in the vertical launching system of warship, and they should be mounted in the same way when vibration-tested. However, mounting missiles vertically makes a fixture, which is a supporting structure, bulky and heavy so requiring a high-performance exciter. Mounting missiles as laid down horizontally in a vibration test is economical regarding fixture manufacturing and exciter performance, but it makes test results incorrect because the different mounting direction has effects on the test results. A bending moment due to missiles' weight happens to missiles, and resilient mounts, which support missiles in the vertical launch system, deflect differently from the real situation because of the static deflection of these mounts due to missiles' weight. If the resilient mounts supporting missiles have nonlinear force-deflection characteristics, vibration test results become more different from the true results. This paper proposes to support missiles with an additional resilient mount such as a bunge code in order to solve those problems coming from mounting vertically-launched missiles as laid down horizontally in vibration tests. The proposed approach enables to obtain the same test results as in their actual mounting condition even though vertically-launched missiles are mounted in a different direction.

배 골판지 포장상자의 진동특성 (Vibration Characteristics of Corrugated Fiberboard Boxes for Packages of Pears)

  • 김만수;정현모
    • Journal of Biosystems Engineering
    • /
    • 제27권5호
    • /
    • pp.391-398
    • /
    • 2002
  • During handling unitized products, they are subjected to a variety of environmental hazards. Shock and vibration hazards are generally considered the most damaging of the environmental hazards on a product and it may encounter while passing through the distribution environment. A major cause of shock damage to products is drops during manual handling. The increasing use of unitization of pallets has been resulted in a reduction of the shock hazards. This has caused an increasing interest in research focused on vibration caused dam age. Damage to the product by the vibration most often occurs when a product or a product component has a natural frequency that falls within the range of the forcing frequencies of the particular mode of transportation being used. Transportation vibration is also a major cause of fruit and vegetable quality loss due to mechanical damage. This study was conducted to determine the vibration characteristics of the corrugated fiberboard bones for packages of pears, and to investigate the degree of vibration injury of the pears in the boxes during the simulated transportation environment. The vibration tests were performed on an electrohydraulic vibration exciter. The input acceleration to exciter was fixed at 0.25 G for a single container resonance test and 0.5 G for the vertical stacked container over the frequency range from 3 to 100 Hz. Function generator (HP-33120A) was connected by wire to the vibration exciter for controlling the input acceleration at a continuous logarithmic sweep rate of 1.0 octave per min. The peak frequency and acceleration on the single box test were 22.02 Hz, 1.5425 G respectively, and these values on the vertical stacked boxes were observed from the bottom box 19.02, 18.14, 16.62 and 15.40 Hz and 2.2987, 3.7654. 5.6087, and 7.9582 G, respectively. The pear in the bottom box had a slightly higher damage level than the fruit packed in the other stacked boxes. It is desirable that the package and transportation system has to be so designed that 15∼20 Hz frequency will not occur during the transportation environment.

건설기계용 카운터웨이트 시험장비 및 가속수명시험법 개발 (Development of the Accelerated Life Test Method & Life Test Equipment for the Counterweight of the Construction Machinery)

  • 이기천;이용범;최병오;강보식;김도식;최종식;김재훈
    • 대한기계학회논문집A
    • /
    • 제39권12호
    • /
    • pp.1275-1280
    • /
    • 2015
  • 카운터웨이트를 수명시험 하기 위해서는 실제 현장과 유사하게 2 톤의 무게를 가진시켜 주는 대형 가진기가 필수적이다. 그렇지만 이러한 장비를 일반업체에서 보유하여 시험하기는 어려우므로, 이러한 애로점을 해소하기 위해 본 연구에서는 첫번째로 2 톤의 중량물일지라도 건설기계의 신뢰성을 평가하는 전기터들로 구성되는 회전식 가진기를 사하여 실제 현장조건을 재현하는 시험장비를 개발하였고, 주요 구성품에 대해 카운터웨이트의 고장해석을 수행하였다. 두번째로 현장으로부터 필드데이터를 측정하여 수명시험에 활할 수 있도록 하였다. 마지막으로 성능과 수명을 확인하기 위해 가속수명시험법을 개발하였고, 제품의 고장발생 없이 $B_5$ 10,000 시간을 만족하는 가속수명시험을 완료하였다.

유동층보일러 수냉벽튜브 결함평가를 위한 원격자장 스캐너 시뮬레이션에 관한 연구 (Simulation of Remote Field Scanner for Defect Evaluation of Water Wall Tube Within the Fluidized Bed Boiler)

  • 길두송;정계조;서정석;김학준;권찬울
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.145-150
    • /
    • 2020
  • 유동층보일러를 구성하는 요소 중 하나인 수냉벽튜브는 외부의 고온 연소 가스를 이용해 물을 증기로 가열하는 튜브군의 하나로써, 보일러를 이용한 전력생산에 중요한 역할을 담당하지만, 고온 가스 및 유동매체로 인해 마모 및 부식이 심하게 일어나면 누수가 발생하게 되고, 누수로 인한 2차 피해도 발생될 뿐만 아니라, 발전 효율이 현저히 떨어지게 되어 수냉벽튜브의 유지보수는 매우 중요하다. 본 연구에서는 원격장 기반의 발신자(Exciter) 센서 설계, 원격장 와전류 시스템 구성, 수냉벽튜브 외벽 결함평가를 목적으로 하였으며, 이를 위한 발신자 형상의 센서 설계를 시작으로, 수냉벽튜브의 크기, 재질, 주파수, Lift-Off (센서와 수냉벽튜브 사이의 거리) 등 여러 가지 요인에 따른 시험을 진행하여 그에 따른 최적의 발신자 센서를 설계하였다.

진동 환경 재현 6-자유도 가진기 개발 진척도 (Progress in Developing the 6-DOF Vibration Environmental Simulator)

  • 정완섭;우춘규;김수현;윤각진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.296-301
    • /
    • 1998
  • In this experiments of design, vibration evaluation, and test of vehicles, aircraft, and other mechanisms the development of vibration simulator that serves environment similar to real fields takes lots of advantages. Especially, in the real field test of vehicles it possesses the advantages of showing the dynamic characteristics of the vehicle. In this study, to investigate the validity and fitness of proposed 6DOF parallel link mechanism we simulated that mechanism.

  • PDF

활성탄 전기체 동특성 시험기법 연구 (Modal Test of Missile Structure with Live Warhead and Propellant)

  • 강휘원;전병희;양명석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.57-60
    • /
    • 2005
  • Modal parameters of a structure are the important factor to control the missile maneuver. In general, a dummy structure is used for the modal test of missile structure instead of the real warhead and propellant because there may be the danger of a explosion by the electric shock of test equipment, such as the exciter and the power amplifier. However, the modal testing of a real missile structure is required to acquire the modal parameters and to analyze the missile performance accurately. The new test system and technique are developed to get rid of the danger and secure the safety during the testing. This test system is made of with the computer network system and controlled remote from test site. Using His new test system, the modal test of real missile structure is performed successfully and its validity is proven.

  • PDF

단락시험에서 후비보호차단기와 투입스위치의 중요 역할 (The study of a primary role of Back up Breaker and Making Switch for Short Circuit Test)

  • 김선구;김선호;김원만;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.915-916
    • /
    • 2007
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, Exciter, CLR, Back Up Breaker, Making Switch and TRV etc. Especially Back up Breaker and Making Switch are very important equipments to test the short circuit test. A role of a Back up Breaker is to break high-voltage and high-current for short circuit test and a Making Switch should be operated always same speed/time and kept electrical-mechanical characteristics to make the voltage and current of short circuit test. This study introduces to the short circuit test also to kinds, principal movements and compare them of Back up Breaker and Making Switch.

  • PDF