Modal Test of Missile Structure with Live Warhead and Propellant

활성탄 전기체 동특성 시험기법 연구

  • Published : 2005.11.17

Abstract

Modal parameters of a structure are the important factor to control the missile maneuver. In general, a dummy structure is used for the modal test of missile structure instead of the real warhead and propellant because there may be the danger of a explosion by the electric shock of test equipment, such as the exciter and the power amplifier. However, the modal testing of a real missile structure is required to acquire the modal parameters and to analyze the missile performance accurately. The new test system and technique are developed to get rid of the danger and secure the safety during the testing. This test system is made of with the computer network system and controlled remote from test site. Using His new test system, the modal test of real missile structure is performed successfully and its validity is proven.

Keywords