• 제목/요약/키워드: Excess Flow

검색결과 299건 처리시간 0.018초

지표면에 의한 음의 초과 감쇠 특성 연구 (A Study on the Characteristics of Excess Attenuation of the Sound due to the Ground)

  • 황철호;정성수
    • 소음진동
    • /
    • 제7권3호
    • /
    • pp.401-409
    • /
    • 1997
  • This study observed the meterological influence on the excess attenuation with various flow resistivities. The flow resistivity is simulated up to 30, 000 cgs rayls. There is no significant differences among results from spherical wave analysis for excess attenuation, from plane wave analysis, and from locally reacting analysis. This is validated only when the flow resistivity is more than 100 cgs rayls. For the determination of effective flow resistivity of ground by measuring the excess attenuation experimentally, it is highly recommended that the distance between source and receiver is about 2.5m, and that the height of them is 0.3-0.4 m in case that they have the same height. Under this proposed conditions, the flow resistivity of 6-month-passed asphalt ground is estimated to 5, 000 cgs rayls by comparing the measured excess attenuation with the calculated.

  • PDF

로타리 킬른의 장입 특성이 온도분포에 미치는 영향 (The Effect of Feeding Characteristics on the Temperature Distribution of Rotary Kiln)

  • 박종석;전철균
    • 한국연소학회지
    • /
    • 제12권3호
    • /
    • pp.24-32
    • /
    • 2007
  • A theoretical model was developed for rotary kiln and computational study was conducted to find the effect of feeding characteristics. One dimensional model with the variations of heating distribution, length of heating zone, excess air ratio and revolution was considered. The comparison of parallel-flow rotary kiln with that of counter-flow was conducted. For parallel-flow type, it is found that the variation of temperature of solid is not great for the zone that is following flame-heating zone. This zone is good to take the special treatment because thermal deviation is small and contacting time is enough for another treatment. Increase of excess air ratio have the effect of decreasing solid temperature. But this effect of decreasing solid temperature goes small for the great excess air ratio. The heating is efficient for the flame which has the maximum heating at the central region of the full length.

  • PDF

연료가스 매몰배관용 과류차단밸브와 성능시험 장치 개발 (Excess Flow Valves for Underground Gas Pipeline and their Performance Testing Equipment Development)

  • 이우귀연;주유경;이진한
    • 한국가스학회지
    • /
    • 제22권4호
    • /
    • pp.74-81
    • /
    • 2018
  • 도시가스 공급이 어려운 지역에 낮은 가격에 가스를 공급하기 위해 대한민국 정부는 20114년부터 LP가스 배관망사업을 추진하였다. LP가스 배관망은 일반 도시가스 배관망과는 다르게 준저압(25kPa~75kPa)로 운용되고 있다. 이는 도시가스의 운용압력보다 최소 10배에서 최대 40배 높은 압력이므로, 타공사 등에 의한 배관파손 시 대형사고로 이어질 가능성이 높다. 이러한 위험성을 줄이기 위해, 한국가스안전공사 가스안전연구원은 2018년 매몰배관용 과류차단밸브와 이를 시험할 수 있는 성능시험 평가 장치를 개발 완료 하였다. 과류차단밸브는 배관 내 과류가 발생하면 자동적으로 닫히면서 가스공급을 순간적으로 차단한다. 과류차단밸브는 일반적으로 주 배관이 아닌 분기배관 최 전단에 설치되며, 분기배관과 연결된 세대나 시설의 최대 가스사용량에 따라 과류차단밸브가 차단되는 기준점인 Trip Flow가 결정된다. Trip Flow는 과류차단밸브 설치의 핵심 기준이며, 이를 시험하기 위한 성능시험 설비도 필수적으로 요구된다.

박막이 부착된 마이크로 채널 내의 유동해석 (flow analysis in Micro Channel with a Couple of Fins)

  • 정재택
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.228-233
    • /
    • 2005
  • Two-dimensional Stokes flows through a micro channel with a couple of symmetric vertical fins are investigated. At far up- and down-stream from the fins, the plane Poiseuille flow exists in the channel. The slip boundary conditions are applied to take account of the Knudsen number effects. For the analysis, the method of eigen function expansion and collocation method are employed. By the results, the streamline patterns and pressure distributions are shown and the force exerted on the fin and the excess pressure drop due to the fins are determined as functions of the length of the fin and Knudsen number. It may be conjectured that the force and the excess pressure drop are almost independent of the Knudsen number.

  • PDF

An Analytical Investigation on the Build-up of the Temperature Field due to a Point Heat Source in Shallow Coastal Water with Oscillatory Alongshore-flow

  • Jung, Kyung-Tae;Kim, Chong-Hak;Jang, Chan-Joo;Lee, Ho-Jin;Kang, Sok-Kuh;Yjm, Ki-Dai
    • Ocean and Polar Research
    • /
    • 제25권1호
    • /
    • pp.63-74
    • /
    • 2003
  • The build-up of the heat field in shallow coastal water due to a point source has been investigated using an analytical solution of a time-integral form derived by extending the solutions by Holley(1969) and also presented in Harleman (1971). The uniform water depth is assumed with non-isotropic turbulent dispersion. The alongshore-flow is assumed to be uni-directional, spatially uniform and oscillatory. Due to the presence of the oscillatory alongshore-flow, the heat build-up occurs in an oscillatory manner, and the excess temperature thereby fluctuates in that course and even in the quasi-steady state. A series of calculations reveal that proper choices of the decay coefficient as well as dispersion coefficients are critical to the reliable prediction of the excess temperature field. The dispersion coefficients determine the absolute values of the excess temperature and characterize the shoreline profile, particularly within the tidal excursion distance, while the decay coefficient determines the absolute value of the excess temperature and the convergence rate to that of the quasi-steady state. Within the e-folding time scale $1/k_d$ (where $k_d$ is the heat decay coefficient), heat build-up occurs more than 90% of the quasi-steady state values in a region within a tidal excursion distance (L), while occurs increasingly less the farther we go to the downstream direction (about 80% at 1.25L, and 70% at 1.5L). Calculations with onshore and offshore discharges indicate that thermal spreading in the direction of the shoreline is reduced as the shoreline constraint which controls the lateral mixing is reduced. The importance of collecting long-term records of in situ meteorological conditions and clarifying the definition of the heat loss coefficient is addressed. Interactive use of analytical and numerical modeling is recommended as a desirable way to obtain a reliable estimate of the far-field excess temperature along with extensive field measurements.

A modified technique for extraoral cementation of implant retained restorations for preventing excess cement around the margins

  • Yuzbasioglu, Emir
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.146-149
    • /
    • 2014
  • The major drawback of cement-retained restorations is the extrusion of the excess cement into the peri-implant sulcus, with subsequent complications. Insufficient removal of the excess cement may initiate a local inflammatory process, which may lead to implant failure. This article presents a method of controlling cement flow on implant abutments, minimizing the excess cement around implant-retained restorations.

선회유동을 이용한 펠릿연소기의 화염안정화 연구 (A Study on The Flame Stability of Pellet Combustor Using Swirling Flow)

  • 이도형;윤봉석;왕진위
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.35-41
    • /
    • 2014
  • The wood pellet, which is one of the woody biomass energy, has very high economic efficiency and combustion efficiency during their combustion. The existing pellet burner have many problems such as low combustion efficiency, flame stabilization, ash problem and ignition time etc. We developed cyclonic wood pellet burner aim to 20,000kcal/hr boiler and measured temperature profiles and exhaust gases in order to investigate the flame stability and optimum combustion condition at any air flow conditions. As results, we confirmed the reappearance and the isotropy of the experimental results in the burner. At the first air flow inlet condition of excess air ratio ${\alpha}=0.02$, second air flow $490{\ell}/min$ had the best combustion condition when pellet supplied 30g. This result means that we need much air supply only for the swirling of second air flow. So we tested various second air flux at first air excess air ratio ${\alpha}=0.7$ condition. At this condition, we could find out that we don't need much second air and total air flux compared to the former condition. We will continuously test this work of air flow distribution, and swirl effect of first air flow, and ash elimination.

국내 LPG 집단공급시설 환경에 적합한 매몰배관용 과류차단밸브 성능시험 절차 개발 (Development of Performance Test Procedure for the Excess Flow Valve for Buried Piping for the Domestic LPG Mass Supply System)

  • 장찬영;이우귀연;이진한
    • 한국가스학회지
    • /
    • 제22권6호
    • /
    • pp.16-27
    • /
    • 2018
  • 대한민국 정부에서 2014년부터 LPG배관망과 LPG소형탱크를 도시가스 공급망 개설이 어려운 산간이나 도서지역에 보급하는 사업을 시작했다. 마을단위와 군단위로 LPG집단공급시설을 설치하면서 기존의 가스공급 압력이 아닌 10배 이상의 높은 준저압(25kPa~100kPa)으로 소비자에게 공급하게 되면서 가스사고의 위험성이 높아졌다. 기존의 가스공급압력보다 10배 이상 높은 압력이기 때문에 가스가 누출 되었을 때 빠른 속도로 많은 양이 누출하게 된다. 이에 준저압 가스배관의 안전성 확보를 위해 과류차단밸브가 필요하게 되었지만, 국내에서는 준저압 매몰배관용 과류차단밸브가 미개발되어 있으며 보급 또한 되어 있지 않는 상황이다. 이에 한국가스안전공사에서는 과류차단밸브의 국산화를 위해 과류차단밸브를 기개발한 해외의 성능기준과 제품을 조사 중에 있으며, 과류차단밸브의 성능평가를 위해 성능시험설비를 구축하여 준저압 연료가스 매몰배관용 과류차단밸브를 연구 개발 중에 있다.

Analysis on the performance and internal flow of a tubular type hydro turbine for vessel cooling system

  • Chen, Zhenmu;Kim, Joo-Cheong;Im, Myeong-Hwan;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1244-1250
    • /
    • 2014
  • The temperature of the main engine cabin of commercial vessel is very high. The material SS-316L undergoes creep damage at temperatures exceeding $450^{\circ}C$. It is essential to maintain the highly stressed engine cabin below the creep regime. Hence, seawater is employed in this kind of maritime vehicles as cooling liquid. It obtains the thermal energy at the cooling pipe line after passing through main engine cooling system. To harness the energy in the seawater, a turbine can be installed to absorb the energy in the seawater before being released into the sea. In this study, a cooling pipe line is selected to apply the tubular type hydro turbine for transferring the energy. Numerical analysis for investigating the performance and the internal flow characteristics of the tubular turbine is conducted. The results show that the maximum efficiency of 85.8% is achieved although the efficiency drops rapidly at partial flow rate condition. The efficiency descends slowly at the condition of excess flow rate. There is a relatively wide operating range of flow rate of this turbine to keep high efficiency at the excess flow rate condition. For the internal flow of the turbine, there is uniform streamline on the suction and pressure sides of the blade at the design point. However, the secondary flow appears at the suction and pressure sidesat the excess flow rate.In addition, it appears only at pressure side at the partial flow rate condition.

$CO_2$ 첨가에 따른 순산소 연소기의 연소특성에 관한 실험적 연구 (Experimental Study on the Oxygen Combustion Characteristics with $CO_2$ Feeding)

  • 서정일;곽영태;배수호;홍정구;이은도;신현동
    • 한국연소학회지
    • /
    • 제10권2호
    • /
    • pp.26-34
    • /
    • 2005
  • The performance of oxygen combustion with $CO_2$ feeding was investigated in a pyrex tube furnace. The inverse type multi-hole burner was used for improving mixing and wide operating range. It introduced oxygen, fuel, and oxygen, respectively, from center tube to outer tubes. Oxygen combustion characteristics with excess oxygen ratio, oxygen feeding ratio, and $CO_2$ feeding flow rate were studied to optimize the operating condition and to apply the oxygen combustion with recirculation of flue gas to a real furnace. This paper presents results on the effect of $CO_2$ feeding flow rate on the structure of the flames and concentrations of NO and CO emissions. The visible flame length was shortest due to well mixing between fuel and oxygen when the oxygen feeding ratio was 0.25. The NO emission was reduced drastically regardless of excess oxygen ratio when the $CO_2$ feeding flow rate was larger than 15 lpm. The CO emission is varied by changing the $CO_2$ feeding flow rate but the CO emission characteristics is highly affected by excess oxygen ratio. When the excess oxygen ratio is below $\lambda=1.1$, the CO emission increased as the $CO_2$ feeding flow rate increased.

  • PDF