• 제목/요약/키워드: Evaluation instrument

검색결과 665건 처리시간 0.03초

중소제조업체의 측정기 운영에 관한 실증적 연구 (A Study on Management for Measuring Instrument of Small and Medium-sized Enterprises)

  • 유재권;유현종
    • 산업융합연구
    • /
    • 제6권2호
    • /
    • pp.43-56
    • /
    • 2008
  • Measurement is used for evaluation of product or process exactly. If it couldn't measured correctly, Quality-cost must be raised and it would be hard to improve product quality. So, this study suggests improvement guide line for the multilateral problems of measuring instrument operation based on the investigation of 157 small and medium-sized enterprises in February, 2008. To use measuring instrument correctly, man who treat it must be accustomed with the structure, the performance, the method. The instrument is selected properly for the measurement goal. If not, results couldn't be correctly or wasted time, efforts, and costs. When selecting a instrument, the tolerance, the size, the figure, the material, and the efficiency must be considered. If the measuring instruments are controlled efficiently, it could be accomplished that improving product quality and coinciding with the goal of QM.

  • PDF

신규간호사 프리셉터의 핵심역략 평가도구 개발 (Development and Validation of the Core Competency Evaluation Tool for New Graduate Nurse's Preceptor)

  • 권인각;정경희;조혜술;황지원;김지영;전경옥;성영희
    • 간호행정학회지
    • /
    • 제8권4호
    • /
    • pp.535-549
    • /
    • 2002
  • Purpose : The purpose of this study was to develop a core competency evaluation tool of the preceptors training new graduate nurses and to determine the validity of the developed instrument. Method : This study was conducted in 2 phases. In phase I, preceptor's core competency list was developed through literature review, focus group interview, and review by nursing directors and nurse managers. In phase II, 60 preceptors were evaluated with the developed instrument and categorized into excellent, good & poor core competency groups. For validation of the instrument, new graduates' clinical performance improvement and satisfaction with preceptor were compared between excellent and poor group. Result : The data were analyzed by SPSS P.C and the results were as follows. 1) Preceptor's core competencies were classified into three domains; Role model(10 items), Socialization facilitator(8 items), and Educator(16 items), and each item had four point system of "strongly agree" to "strongly disagree". Cronbach'${\alpha}$ of the instrument was.9416. 2) Comparison of clinical performance improvement and satisfaction with preceptor of the new graduates trained by excellent and poor preceptors revealed that new graduates' clinical performance improvement(p=.015) and satisfaction with the preceptor(p=.005) were significantly higher in the excellent core competency preceptor group than the poor core competency preceptor group. Conclusion : The validity of the preceptor's core competency evaluation tool developed in this study was confirmed. Therefore, this tool can be effectively utilized for education and evaluation of new graduates' preceptors in clinical settings.

  • PDF

헬스케어 재활훈련기 디자인 평가 요소 개발에 관한 연구 (A Study of Evaluation Index Development of Healthcare Rehabilitation Device Design)

  • 조재상;권대규;홍정표
    • 감성과학
    • /
    • 제17권3호
    • /
    • pp.129-142
    • /
    • 2014
  • 오늘날 고령인구의 증가와 장애인 인구의 증가로 인해 재활훈련기의 수요가 증가하고 있고, 재활훈련기와 사용자간의 제공받아야 할 서비스에 대한 평가 요소의 요구가 커지고 있다. 본 연구에서는 재활훈련기 디자인 평가에 있어서 평가 방안을 모색하기 위해 디자인 평가를 위한 기본 요소를 파악하고 이를 통하여 재활의료전문가, 의공학자, 디자이너들의 토의 및 분석, 실험을 통하여 새로운 평가 요소들을 도출하였다. 연구의 결과는 다음과 같이 요약된다. 첫째, 기존 디자인 평가 요소들을 수집, 분석하여 10가지의 재활훈련기 디자인 평가요소와 44개의 세부 평가항목을 구축하였다. 이는 앞으로 재활훈련기를 디자인하는데 있어서 중요한 평가 기준이 될 것이다. 둘째, 헬스케어 재활훈련기 디자인 개발 시 고려해야 할 디자인 평가요소로는 사용성, 인지성, 안전성, 학습성, 운동성, 내구성, 경제성, 공간성, 심미성, 환경성의 10가지 디자인 평가요소가 있다. 셋째, 환경성, 공간성, 인지성, 사용성, 경제성, 심미성의 디자인 평가요소는 제품디자인에서 공통적으로 고려해야 할 요소들이고, 학습성, 안전성, 운동성, 내구성의 요소는 재활훈련기 디자인 평가요소에서 매우 중요하게 고려해야 할 요소이다. 넷째, 재활훈련기 디자인 평가요소는 제품디자인요소에서 중요하게 고려되는 환경성, 공간성, 인지성, 사용성, 경제성, 심미성에 학습성, 안전성, 운동성, 내구성을 의 요소를 더해 중요하게 생각한 것이 기존 제품디자인 평가요소와 재활훈련기 디자인 평가요소의 차이점이다. 본 연구에서는 10개의 재활훈련기 디자인 평가요소와 44개의 세부 평가항목 구축에 대한 연구를 진행하였다. 이는 전체적인 재활훈련기 디자인 평가요소만을 연구한 것으로, 향후연구에서는 시 제품 제작을 통하여 평가요소들을 실제 재활훈련기 디자인에 적용해 보고, 미진한 점들을 수정 보완할 예정이다.

저항기를 이용한 계기용 변성기 부담 자동 평가 장치 개발 (Development of Automatic Evaluation Equipment for Burden of Instrument Transformer using Resistor Simulator)

  • 이영섭;정재갑
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.589-595
    • /
    • 2014
  • The error of instrument transformers is measured by connecting the external burden with the secondary terminal of the instrument transformers. Because the error of transformer is affected by the apparent power and power factor of the external burden, an accurate measurement of burden is important for transformer evaluation. We have developed the burden evaluation equipment for both potential transformer and current transformer by employing the series resistor in the range of $20m{\Omega}{\sim}5{\Omega}$ and the parallel resistor in the range of $1M{\Omega}{\sim}500{\Omega}$, respectively, together with visual basic program. We could reduce testing time more than 5 times by employing method developed in this study, compared with that developed in past. This method shows more better reliability by analyzing the evaluation results and fitting graphs of burden measurements. The test results of the developed system is compared with those obtained in the power meter analyzer to verify the validity.

전원용 SPD의 건전성 평가 장치 개발 (Development of Integrity Evaluation Instrument for the Power Line Surge Protective Device)

  • 장석훈;김영진;김성주;김재형
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.39-45
    • /
    • 2015
  • This paper deals with development of integrity evaluation instrument for the power line surge protective device. A reliable power supply is an essential element in the developed information and communication society by highly advances in IT technology. However, the lightning incidence also increased with the recent extreme weather events. In Korea, in order to protect the electrical system from lightning surge, SPD(Surge Protective Device) has been used for these past 30 years. However, the method of diagnosing the safety of the SPD in the industry is insufficient. In this paper, SPD integrity evaluation system was composed of a variable DC power source unit, voltage-current sensor and the embedded controller. In order to measure V-I characteristics of MOV, 3 type samples were degraded by impulse current generator. After impulse tests, the varistor voltage of all samples and nonlinearity coefficient were decreased. It confirmed the utility of the developed equipment by this experimental test and the reliability of SPD is expected for surge accident prevention when applied to industrial plant.

Standardized Design of the Transmitting Coils in Inductive Coupled Endoscope Robot Driving Systems

  • Ke, Quan;Jiang, Pingping;Yan, Guozheng
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.835-847
    • /
    • 2017
  • A transmitting coil with an optimal topology and number of turns can effectively improve the performance of the wireless power transfer (WPT) systems for endoscope robots. This study proposes the evaluation parameters of the transmitting coils related to the performance of the WPT system to standardize the design of the transmitting coils. It considers both the quality factor of transmitting coils and the coupling factor between the two sides. Furthermore, an analytical model of transmitting coils with different topologies is built to exactly estimate the evaluation parameters. Several coils with the specified topologies are wound to verify the analytical model and the feasibility of evaluation parameters. In the case of a constant power received, the related evaluation parameters are proportional to the transfer efficiency of the WPT system. Therefore, the applicable frequency ranges of transmitting coils with different topologies are determined theoretically. Then a transmitting coil with a diameter of 69 cm is re-optimized both theoretically and experimentally. The transfer efficiency of the WPT system is increased from 3.58% to 7.37% with the maximum magnetic field intensity permitted by human tissue. Finally, the standardized design of the transmitting coil is achieved by summing-up and facilitating the optimization of the coils in various situations.

임상실습지도자의 효율성 조사와 임상평가도구 개발 (A Survey of Teaching Effectiveness and the Development of an Evaluation Instrument for Clinical Education)

  • 권미지
    • The Journal of Korean Physical Therapy
    • /
    • 제14권1호
    • /
    • pp.177-186
    • /
    • 2002
  • The purpose of this study was to contribute to the development of clinical instruction by students ratings of teaching effectiveness in clinical education. The instrument used in this study was teaching effectiveness of clinical nursing by Yu and modified evaluation method by Kern and Mickelson. The results were are follows 1. Among the 12 categorial components of clinical teaching effectiveness, the highest satisfaction was 'encouraging to think for themselves' and the lowest was 'attitude of teacher and evaluation' 2. To compare teaching effectiveness between sex, 'resource for student' and 'professional competence' showed statistical significance. 3. To compare teaching effectiveness among clinical practice stage, 'encouraging' 'role model', 'professional competence', 'organization of subject mater' and 'attitude of teacher and evaluation' showed statistical significance. 5. Interrater ICCs for evaluation method did not showed statistical significance and interitem ICCs showed statistical significance. This article presents goal of clinical education, development of clinical instructor's educational program and a standardized method to measure clinical performance.

  • PDF

가정간호 서비스 질 평가를 위한 도구개발연구 (A basic research for evaluation of a Home Care Nursing Delivery System)

  • 김모임;조원정;김의숙;김성규;장순복;유호신
    • 가정간호학회지
    • /
    • 제6권
    • /
    • pp.33-45
    • /
    • 1999
  • The purpose of this study was to develop a basic framework and criteria for evaluation of quality care provided to patients with the attributes of disease in the home care nursing field, and to provide measurement tools for home health care in the future. The study design was a developmental study for evaluation of hospital-based HCN(home care nursing) in Korea. The study process was as follows: a home care nursing study team of College of Nursing. Yonsei University reviewed the nursing records of 47 patients who were enrolled at Yonsei University Medical Center Home Care Center in March, 1995. Twenty-five patients were insured at that time, were selected from 47 patients receiving home care service for study feasibility with six disease groups; Caesarean Section (C/S), simple nephrectomy, Liver cirrhosis(LC), chronic obstructive pulmonary disease(COPD), Lung cancer or cerebrovascular accident(CVA). In this study, the following items were selected : First step : Preliminary study 1. Criteria and items were selected on the basis of related literature on each disease area. 2. Items were identified by home care nurses. 3. A physician in charge reviewed the criteria and content of selected items. 4. Items were revised through preliminary study offered to both HCN patients and discharged patients from the home care center. Second step : Pretest 1. To verify the content of the items, a pretest was conducted with 18 patients of which there were three patients in each of the six selected disease groups. Third step : Test of reliability and validity of tools 1. Using the collected data from 25 patients with either cis, Simple nephrectomy, LC, COPD, Lung cancer, or CVA. the final items were revised through a panel discussion among experts in medical care who were researchers, doctors, or nurses. 2. Reliability and validity of the completed tool were verified with both inpatients and HCN patients in each of field for researches. The study results are as follows: 1. Standard for discharge with HCN referral The referral standard for home care, which included criteria for discharge with HCN referral and criteria leaving the hospital were established. These were developed through content analysis from the results of an open-ended questionnaire to related doctors concerning characteristic for discharge with HCN referral for each of the disease groups. The final criteria was decided by discussion among the researchers. 2. Instrument for measurement of health statusPatient health status was measured pre and post home care by direct observation and interview with an open-ended questionnaire which consisted of 61 items based on Gorden's nursing diagnosis classification. These included seven items on health knowledge and health management, eight items on nutrition and metabolism, three items on elimination, five items on activity and exercise, seven items on perception and cognition, three items on sleep and rest, three items on self-perception, three items on role and interpersonal relations, five items on sexuality and reproduction, five items on coping and stress, four items on value and religion, three items on family. and three items on facilities and environment. 3. Instrument for measurement of self-care The instrument for self-care measurement was classified with scales according to the attributes of the disease. Each scale measured understanding level and practice level by a Yes or No scale. Understanding level was measured by interview but practice level was measured by both observation and interview. Items for self-care measurement included 14 for patients with a CVA, five for women who had a cis, ten for patients with lung cancer, 12 for patients with COPD, five for patients with a simple nephrectomy, and 11 for patients with LC. 4. Record for follow-up management This included (1) OPD visit sheet, (2) ER visit form, (3) complications problem form, (4) readmission sheet. and (5) visit note for others medical centers which included visit date, reason for visit, patient name, caregivers, sex, age, time and cost required for visit, and traffic expenses, that is, there were open-end items that investigated OPD visits, emergency room visits, the problem and solution of complications, readmissions and visits to other medical institution to measure health problems and expenditures during the follow up period. 5. Instrument to measure patients satisfaction The satisfaction measurement instrument by Reisseer(1975) was referred to for the development of a tool to measure patient home care satisfaction. The instrument was an open-ended questionnaire which consisted of 11 domains; treatment, nursing care, information, time consumption, accessibility, rapidity, treatment skill, service relevance, attitude, satisfaction factors, dissatisfaction factors, overall satisfaction about nursing care, and others. In conclusion, Five evaluation instruments were developed for home care nursing. These were (1)standard for discharge with HCN referral. (2)instrument for measurement of health status, (3)instrument for measurement of self-care. (4)record for follow-up management, and (5)instrument to measure patient satisfaction. Also, the five instruments can be used to evaluate the effectiveness of the service to assure quality. Further research is needed to increase the reliability and validity of instrument through a community-based HCN evaluation.

  • PDF

자동차 계기판 BSR 소음특성 평가 (Evaluation of BSR Noise Properties of Instrument Panel in a Vehicle)

  • 신수현;정철웅;김덕환;정성수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.330-331
    • /
    • 2010
  • In this paper, BSR noise from an instrument panel of a vehicle are investigated with integrated experimental methods. First, potential source regions of the instrument panel for BSR are localized by using the module-excitor and near-acoustic field visualization system. Then, subjective evaluation of BSR nosie from the detected potential noise source regions is made with the Zwicker's loudness and time-varying loudness methods.

  • PDF

죽음 관련 교과목의 교과내용 평가 도구개발 (Development of an Evaluation Instrument for Subjects Related to Death)

  • 조계화;이현지;이윤주
    • 대한간호학회지
    • /
    • 제36권1호
    • /
    • pp.74-83
    • /
    • 2006
  • Purpose: The purpose of this study was to develop an evaluation instrument integrated and interdisciplinary death education for the human service areas such as nursing, social welfare, and education and to test the reliability and validity of it. Method: The subjects used to verify the instrument's reliability and validity were 407 students who were enrolled in the departments of nursing, social welfare, and education in universities located in Seoul, Pusan, Daegu, and Daejeon. The data was collected from April to May, 2005, and was analyzed by SPSS/WIN 12. Result: A factor analysis was conducted. Items with over a .40 factor loading and over a 1.0 eigen value were selected. Nine identified factors were learning about death, role of professionals, personal attitudes, hospice care, ethics and legal issues, death and dying, spiritual aspect of' death, transcultural aspect of death, and multidisciplinary theory of death. The instrument consisted of 44 items and the reliability was a cronbach's of .953 Conclusion: Based on the study results, the content scale developed in this study was identified as a tool with a high degree of reliability and validity.