• Title/Summary/Keyword: Evaluating quality

Search Result 1,624, Processing Time 0.028 seconds

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

The Evaluation of TrueX Reconstruction Method in Low Dose (저선량에서의 TrueX 재구성 방법에 의한 유용성 평가)

  • Oh, Se-Moon;Kim, Kye-Hwan;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • Purpose: Recently in diagnostics area PET/CT is using a variety of areas including oncology, as well as in cardiology, neurology, etc. While increasing in the importance of PET/CT, there are various researches in the image quality related to reconstruction method. We compared and tested Iterative 2D Reconstruction Method with True X Reconstruction method by Siemens through phantom experiment, so we can see increasing of clinical usefulness of PET/CT. Materials and Methods: We measured contrast ratio and FWHM due to evaluating images on dose and experiment using Biograph 40 True Point PET/CT (Siemens, Germany). Getting a result of contrast ratio and FWHM, we used NEMA IEC PET body phantom (Data Spectrum Corp.) and capillary tube. We used the current TrueX and the previous Iterative 2D algorithm for all images which have 10 minutes long. Also, a clinical suitability of parameter for Iterative 2D and a recommended parameter by Siemens for True X are applied to the experiment. Results: We tested FWHM using capillary tube. As a result, TrueX was less than Iterative 2D. Also, the differences of FWHM get bigger in low dose. On the other hand, we tested contrasts ratio using NEMA IEC PET body phantom. As a result, TrueX was better aspect than Iterative 2D. However, there was no difference in dose. Conclusion: In this experiment, TrueX get higher results of contrast ratio and spatial resolution than Itertive 2D through experiment. Also, in the reconstruction result through TrueX, TrueX had better aspect of resolution than Iterative 2D in low dose. However, contrast ratio had no specific difference. In other words, TrueX reconstruction method in PET/CT had higher clinical value in use because TrueX can reduce exposure of patient and had a better quality of screen.

  • PDF

The study on outpatient-clinic practice by shift system at a hospital in Taegu (대구지역 한 중소병원의 교대제 근무에 의한 외래진료에 관한 연구)

  • Song, Jung Hup;Kim, Jing Kyun;Ha, Young Ae;Yeh, Min Hae
    • Quality Improvement in Health Care
    • /
    • v.1 no.2
    • /
    • pp.44-59
    • /
    • 1994
  • Medical consumers(patients) want evening-clinic because of busy work. For patient's convenience and improving service, hospital should accept it. Considering payment system and patient's demand, personnel expenses, hospital can not accept. The practice of shift system to accept patient's demand and hospital's economic aspect was made. To analysis the effect of the system and probability to alternative to evening clinic this study was done. This study was composed of basal study, intervention, evaluation of effect. The basal study were composed of studying demand on evening clinic, the number of beds, doctors employee, the time table of practice and work, and the number of patients at arrival time. The intervention composed of changing of practice time, changing of working time by the number of patients at arrival time, increasing of employee. The evaluation of effect were composed of evaluating the number of patient at time, the effect of shift system, the comparison of the number of in and out patients and questionnairing the practice of shift system. In the practice time at 2 shift system First team works 7-15 hours and Second team 12-20 hours. there are no lunch and supper time. At 18-20 hours the number of patients were 25-30. The number of patient a depart were 6-7. The number of out-patient increase in 13% and inpatient increase in 10% before the system. Doctors(100%), employee(94.6%), and patients(86.4%) approved this system. The advantage of this system were utilization of surplus time, lengthen the practice time, even distribution of patients and shortening of waiting time, rapid treatment of emergent patients. The disadvantage of this system were shortage of manpower, not all depart practice, continuity of practice, no lunch and supper time, irregular rounding. At present because of small Demanding on evening clinic, this shift system was economical. To succeed this study more effectively all depart in hospital participate. But because of economical reason it is impossible for hospital to do it. If the government assist the economic loss that all depart participate in this system it is very helpful for hospital to succeed in implementing this system more early.

  • PDF

Effect of Sample Preparations on Prediction of Chemical Composition for Corn Silage by Near Infrared Reflectance Spectroscopy (시료 전처리 방법이 근적외선분광법을 이용한 옥수수 사일리지의 화학적 조성분 평가에 미치는 영향)

  • Park Hyung-Soo;Lee Jong-Kyung;Lee Hyo-Won;Hwang Kyung-Jun;Jung Ha-Yeon;Ko Moon-Suck
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.26 no.1
    • /
    • pp.53-62
    • /
    • 2006
  • Near infrared reflectance spectroscopy (NIRS) has been increasingly used as a rapid, accurate method of evaluating some chemical compositions in forages. Analysis of forage quality by NIRS usually involves dry ground samples. Costs might be reduced if samples could be analyzed without drying or grinding. The objective of this study was to investigate effect of sample preparations and spectral math treatments on prediction ability of chemical composition for corn silage by NIRS. A population of 112 corn silage representing a wide range in chemical parameters were used in this investigation. Samples of com silage were scanned at 2nm intervals over the wavelength range 400-2500nm and the optical data recorded as log l/Reflectance(log l/R) and scanned in overt-dried grinding(ODG), liquid nitrogen grinding(LNG) or intact fresh(IF) condition. Samples were analysed for neutral detergent fiber(NDF), acid detergent fiber(ADF), acid detergent lignin(ADL), crude protein(CP) and crude ash content were expressed on a dry-matter(DM) basis. The spectral data were regressed against a range of chemical parameters using modified partial least squares(MPLS) multivariate analysis in conjunction with four spectral math treatments to reduce the effect of extraneous noise. The optimum calibrations were selected on the basis of minimizing the standard error of cross validation(SECV). The results of this study show that NIRS predicted the chemical parameters with very high degree of accuracy(the correlation coefficient of cross validation$(R^2cv)$ range from $0.70{\sim}0.95$) in ODG. The optimum equations were selected on the basis of minimizing the standard error of prediction(SEP). The Optimum sample preparation methods and spectral math treatment were for ADF, the ODG method using 2,10,5 math treatment(SEP = 0.99, $R^2v=0.93$), and for CP, the ODG method using 1,4,4 math treatment(SEP = 0.29. $R^2v=0.91$).

Relationship between Quality of Frozen Surimi and Jelly Strength of Kamaboko (동결 surimi의 품질과 어묵 젤리 강도의 관계)

  • KIM Yuck-Yong;CHO Young-Je
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.2
    • /
    • pp.73-78
    • /
    • 1992
  • To investigate the desirable index for evaluation of frozen surimi's grades, the relationship between indices for grading of surimi, such as ATPase activity $(Ca^{2+}-,\;Mg^{2+}-\;and\;EDTA-)4, solubility, viscosity and K-value of frozen surimi and jelly strength of kamaboko was studied. The myofibrillar $Ca^{2+}-ATPase$ activity and solubility from frozen surimi of grades SA, FA, A, RA and B gave values of $1.184\pm0.2,\;0.956\pm0.14,\;0.766\pm/0.07,\;0.453\pm0.07\;and\;0.227\pm0.08$(umoles Pi/min/mg) for $Ca^{2+}-$ATPase activity and $93.19\pm5,\;84.62\pm4,\;70.63\pm5,\;41.21\pm4\;and\;32.82\pm4(\%)$ for solubility, respectively. Therefore, the myofibrillar $Ca^{2+}-$ATPase activity and solubility of surimi were closely related to the jelly strength of kamaboko from same material, as the correlation coefficient were 0.9584 and 0.9849, respectively. K-value, the index of freshness, was related to the jelly strength of frozen surimi as the correlation coefficient 0.9053 and shown as SA $15.67\pm1.4,\;FA\;14.94\pm 3,\;A\;28.00\pm5,\;RA\;32.16\pm3\;and \;B\;48.68\pm 5(\%)$. $Mg^{2+}-$ and EDTA-ATPase activity and viscosity were not related to the jelly strength. The $Ca^{2+}-$ATPase activity and solubility were found to be useful index for evaluating the quality of frozen surimi.

  • PDF

Usability index evaluation system for mobile WAP service (무선인터넷 서비스 사용성 지수 평가 체계)

  • Park, Hwan-Su
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02b
    • /
    • pp.152-157
    • /
    • 2008
  • The customer satisfaction of WAP service greatly relies on the usability of the service due to the limited display size of a mobile phone and limitation in realizing UI (User Interface) for function keys, browser, and OS (operating system) Currently, a number of contents providers develop and deliver varying services, and thus, it is critical to control quality level of UI in consistent standards and manner. This study suggests usability index evaluation system to achieve consistent UI quality control of various WAP services. The system adopts both top-down and bottom-up approaches. The former concerns deriving UI design components and evaluation checklists for the WAP, based on the usability attributes and UI principles. The latter concerns deriving usability-related evaluation checklists from the established UI design features, and then grouping them from the viewpoint of usability principles and attributes. This bidirectional approach has two outstanding advantages: it allows thorough examination of potential elements that can cause usability problems from the standpoint of usability attributes, and also derives specific evaluation elements from the perspective of UI design components that are relevant to the real service environment. The evaluation system constitutes a hierarchical structure by networking usability attributes, UI guideline which indicates usability principles for each attribute, and usability evaluation checklist for each UI component that enables specific evaluation. Especially, each evaluation checklist contains concrete contents and format so that it can be readily marked in O/X. The score is based on the ratio of number of items that received positive answer to the number of total items. This enables a quantitative evaluation of the usability of mobile WAP service. The validity of the proposed evaluation system has been proved through comparative analysis with the real usability problems based on the user test. A software was developed that provides guideline for evaluation objects, criteria and examples for each checklist, and automatically calculates a score. The software was applied to evaluating and improving the real mobile WAP service.

  • PDF

Evaluation of Laying Performances in Laying Hens Molted by Dietary Induction (산란계의 유도 환우에 있어서 급이환우 방법의 평가)

  • Hong, E.C.;Na, J.C.;Chung, I.B.;Choi, Y.H.;Park, H.D.;Chung, W.T.;Lee, H.J.;You, D.C.;Kim, H.K.;HwangBo, J.
    • Korean Journal of Poultry Science
    • /
    • v.35 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • This study aimed at evaluating the effects of a molting diet method in molt induction and post-molt performance of laying hens. Eighty-one ISA Brown hens at 62 wk of age were randomly divided into three groups. After a 4-wk preliminary period, a control group was fed a corn-soybean-based layer diet, and for the other groups, molting was induced by starvation (MS) or feeding a molting diet (MD). For the MS group, feed was withdrawn for 2 wk; this was followed by feeding a layer diet every other day for 1 wk and then the control diet. The MD group was fed a molting diet containing low-protein and low-energy diet based for 4 wk; this was followed by feeding a layer diet. They had a free access to their diet and water. Egg production, egg quality, feed intake, and ovary and oviduct weights were measured throughout the experimental period. During molting, the feed intake in the MD group was lower than that of the control. Body weight of the molted groups was significantly reduced. The MS group feeding totally ceased egg production within 4d; after the initiation of feeding and decreased; in the MD group, egg production to 9.3% by d 10. On d 14, the ovaries and oviducts of the molted groups were distinctly lighter than those of the control. Throughout the post-molt period, egg production and egg shell thickness of the molted group improved; but there were no significant differences. Eggs from the MD-fed or control group were heavier than those of the MS-fed or control group. Finally, feeding of a low-protein and low-energy diet effectively induces molting and increase post-molt production, but further research will be conducted to determine the effects of the molt diet with other ingredients and to reduce the energy level of the molt diet for maximizing molt induction and post-molt egg quality.

Effect of Sample Preparation on Predicting Chemical Composition and Fermentation Parameters in Italian ryegrass Silages by Near Infrared Spectroscopy (시료 전처리 방법이 근적외선분광법을 이용한 이탈리안 라이그라스 사일리지의 화학적 조성분 및 발효품질 평가에 미치는 영향)

  • Park, Hyung Soo;Lee, Sang Hoon;Choi, Ki Choon;Lim, Young Chul;Kim, Jong Gun;Seo, Sung;Jo, Kyu Chea
    • Journal of Animal Environmental Science
    • /
    • v.18 no.3
    • /
    • pp.257-266
    • /
    • 2012
  • Near infrared reflectance spectroscopy (NIRS) has become increasingly used as a rapid, accurate method of evaluating some chemical constituents in cereal and dired animal forages. Analysis of forage quality by NIRS usually involves dry grinding samples. Costs might be reduced if samples could be analyzed without drying or grinding. The objective of this study was to investigate effect of sample preparations on prediction ability of chemical composition and fermentation parameter for Italian ryegrass silages by NIRS. A population of 147 Italian ryegrass silages representing a wide range in chemical parameters were used in this investigation. Samples were scanned at 1nm intervals over the wavelength range 680-2500 nm and the optical data recorded as log 1/Reflectance (log 1/R) and scanned in oven-dried grinding and fresh ungrinding condition. The spectral data were regressed against a range of chemical parameters using partial least squares (PLS) multivariate analysis in conjunction with four spectral math treatments to reduced the effect of extraneous noise. The optimum calibrations were selected on the basis of minimizing the standard error of cross validation (SECV) and maximizing the correlation coefficient of cross validation (${R^2}_{CV}$). The results of this study show that NIRS predicted the chemical parameters with high degree of accuracy in oven-dried grinding treatment except for moisture contents. Prediction accuracy of the moisture contents was better for fresh ungrinding treatment (SECV 1.37%, $R^2$ 0.96) than for oven-dried grinding treatments (SECV 4.31%, $R^2$ 0.68). Although the statistical indexes for accuracy of the prediction were the lower in fresh ungrinding treatment, fresh treatment may be acceptable when processing is costly or when some changes in component due to the processing are expected. Results of this experiment showed the possibility of NIRS method to predict the chemical composition and fermentation parameter of Italian ryegrass silages as routine analysis method in feeding value evaluation and for farmer advice.

Evaluation of the Usefulness of Assist Device for Rosenberg View Test (Rosenberg View 검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Kim, In Soo;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.129-138
    • /
    • 2020
  • Due to the nature of the Rosenberg Method, the patient needs to maintain posture for a certain period of time, and the joint space is observed in various forms depending on the angle of knee flexion, which causes difficulties in examination. In order to solve these problems, Image quality was evaluated in order to evaluate the usefulness of the assistive device by making the assistive device itself. SNR and CNR analysis about the presence or absence of an assistive device using the extremity phantom and the angle of the assistive device itself were not statistically significant(p < 0.05). As a result of measuring the distance between the right and left edges of the medial condyle based on the presence or absence of an assist device, and the absence of assist device (96.00±40.6 mm) and presence of an assist device (134.86±17.68 mm) were statistically significant (p <0.05). To find the aLDFA relationship about the femur and tibia, we measured the right and left aLDFA based on the presence or absence of assist device. As a result, the absence of the right-side aLDFA assist device (74.63°±4.87) and the presence of assist device (79.64°±3.65) were statistically significant (p <0.05). The absence of the left-side aLDFA assist device (76.39°±4.62) and the presence of assist device (79.64°±3.65) were statistically significant (p < 0.05). but, As a result of measuring the distance of the overlapping parts of the right and left proximal tibiofibular joint and the lateral condyle, There were no statistically significant differences between the right and left sides. In conclusion, we confirmed that we can obtain Diagnostically valuable images with a constant knee-to-knee spacing using an assist device we self-created. In addition, we could learn through aLDFA relationship between femur and tibial that the smaller the angle, the more medial condyle overlaps with JSW, We also confirmed the significance by deriving similar values on the normal range values of aLDFA using assist devices. However, it is considered necessary to pay attention to internal and external rotations in order to obtain good quality images by evaluating the distance of overlapping parts between proximal tibiofibular joint and lateral condyle.