Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator
![]() |
Lee, Soon Sung
(Radiological & Medico-Oncological Sciences, University of Science and Technology)
Choi, Sang Hyoun (Research Center for Radiotherapy, Korea Institute of Radiological and Medical Sciences) Min, Chul Kee (Department of Radiation Oncology, Soon Chun Hyang University Hospital Cheonan) Kim, Woo Chul (Department of Radiation Oncology, Soon Chun Hyang University Hospital Cheonan) Ji, Young Hoon (Radiological & Medico-Oncological Sciences, University of Science and Technology) Park, Seungwoo (Research Center for Radiotherapy, Korea Institute of Radiological and Medical Sciences) Jung, Haijo (Radiological & Medico-Oncological Sciences, University of Science and Technology) Kim, Mi-Sook (Radiological & Medico-Oncological Sciences, University of Science and Technology) Yoo, Hyung Jun (Department of Radiation Oncology, Korea Institute of Radiological and Medical Sciences) Kim, Kum Bae (Radiological & Medico-Oncological Sciences, University of Science and Technology) |
1 | Lee L, Le QT, Xing L: Retrospective IMRT dose reconstruction based on cone-beam CT and MLC log-file. Int J Radiat Oncol Biol Phys 70:634-644 (2008) DOI |
2 | Han YY: Review on the Pre-treatment Quality assurance for intensity modulated radiation therapy. Progress in MEDICAL PHYSICS 24(4):213-219 (2013) DOI |
3 | Park SY, Park YK, Park JM et al: MU Fluence reconstruction based-on delivered leaf position for IMRT quality assurance. JOURNAL OF RADIATION PROTECTION 38(1):28-34 (2011) |
4 | Graves MN, Thompson AV, Martel MK et al: Calibration and quality assurance for rounded leaf-end MLC systems. Med Phys 28(11):2227-2233 (2001) DOI |
5 | Lee JW, Choi KS, Hong S et al: Effects of static dosimetric leaf gap on MLC-based small beam dose distribution for intensity- modulated radiosurgery. J Appl Clin Med Phys 8(4): 54-65 (2007) DOI |
6 | Kielar KN, Mok E, Hsu A et al: Verification of dosimetric accuracy on the TrueBeam STx: Rounded leaf effect of the high definition MLC. Med Phys 39(10):6360-6371 (2012) DOI |
7 | Varian Medical Systems: dosimetric leaf gap Measurement Guide. |
8 | Klein EE, Hanley J, Bayouth J et al: Task Group 142 report: Quality assurance of medical accelerators. Med Phys 36(9): 4197-4212 (2009) DOI |
9 | Rangel A and Dunscombe P: Tolerances on MLC leaf position accuracy for IMRT delivery with a dynamic MLC. Med Phys 36(7): 3304-3309 (2009) DOI |
10 | Ezzell GA, Buumeister JW, Dogan N et al: IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 36: 5359-5373 (2009) DOI |
11 | Fontenot JD: Evaluation of a novel secondary check tool for intensity modulated radiotherapy treatment planning. J Appl Clin Med Phys 15(5):207-215 (2014) DOI |
12 | Mei X, Nygren I, Villarreal-Barajas JE: On the use of the MLC dosimetric leaf gap as a quality control tool for accurate dynamic IMRT delivery, Med Phys, 38(4):2246-2255 (2011) DOI |
13 | Kayla NK, Ed M, Annie H et al: Verification of dosimetric accuracy on the TrueBeam STx_Rounded leaf effect of the high definition MLC, Med Phys, 39(10):6360-6370 (2012) DOI |
14 | LoSasso T, Chui CS, Ling C: Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy, Med Phys ,25(10):1919-1927 (1998) DOI |
15 | Zhen H, Nelms BE, Tome WA et al: Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA, Med Phys 38(10):5447-5489 (2011) |
![]() |