• Title/Summary/Keyword: Evacuation facilities

Search Result 212, Processing Time 0.03 seconds

A Study on the Establishment of Disaster Prevention Plans for Nuclear Facilities considering Complex Disasters (복합재난을 고려한 원자력시설 사고대비 방재계획 수립방안)

  • Jihoon Shin;Younwon Park;Seunghyeon Kim;Minho Cha;Minsang Ryu
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.85-99
    • /
    • 2023
  • By the social advancement, radiological disaster prevention planning is getting important considering complex disasters as in the Fukushima radiological disaster occurred by a chain of natural disasters. However, it has yet to be suggested the specific prevention plans for the complex disasters in the field of national radiological disaster prevention. This study aims to analyze the types of complex disasters in order to select the ones that are relatively more likely to occur in the domestic environment. It is also to analyze the impact on the radiological disaster prevention by searching damage spread of the classified natural disasters. We provides the necessary criterial for establishing disaster prevention plans through the scenarios for radiological emergency responses based on complex disasters. it is thought that these criteria can help prepare for the worst case scenario and implement effective resident protection.

A Study on Strengthening Consequence Management System Against CBRN Threats (CBRN 위협에 대비한 사후관리체계 강화방안)

  • Kwon, Hyuckshin;Kwak, Minsu;Kim, Kwanheon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.4
    • /
    • pp.429-435
    • /
    • 2020
  • North Korea declared itself complete with nuclear force after its sixth nuclear test in 2017. Despite efforts at home and abroad to denuclearize the Korean Peninsula, the prospects for the denuclearization are not bright. Along with political and diplomatic efforts to deter NK's WMD threats, the government is required to strengthen its consequence management capabilities against 'catastrophic situations' expected in case of emergency. Accordingly, this study was conducted to present measures to strengthen follow-up management against CBRN threats. The research model was partially supplemented and utilized by the THIRA process adopted and utilized by the U.S. Department of Homeland Security among national-level disaster management plan development models. Korea's consequence management (CM) system encompasses risk and crisis management on disaster condition. The system has been carried out in the form of a civil, government and military integrated defense operations for the purpose of curbing the spread or use of CBRNs, responding to threats, and minimizing expected damages. The preventive stage call for the incorporation of CBRN concept and CM procedures into the national management system, supplementing the integrated alarm systems, preparation of evacuation facilities, and establishment of the integrated training systems. In the preparation phase, readjustment of relevant laws and manuals, maintenance of government organizations, developing performance procedures, establishing the on-site support systems, and regular training are essential. In the response phase, normal operations of the medical support system for first aid and relief, installation and operation of facilities for decontamination, and development of regional damage assessment and control guidelines are important. In the recovery phase, development of stabilization evaluation criteria and procedures, securing and operation of resources needed for damage recovery, and strengthening of regional damage recovery capabilities linked to local defense forces, reserve forces and civil defense committees are required.

A study on the case analysis of Nitric acid chemical accident and establishment of preventive measures (질산 화학사고 사례분석 및 독성피해 영향범위에 대한 연구)

  • Lee, Hyun-Seung;Shin, Chang-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.488-496
    • /
    • 2020
  • This study was based on nitrate chemical accidents at home and abroad. Toxic gases due to adverse reactions are generated in the workplace, laboratory, hospital, container damage, and chemical misinjection. Through a case review of possible situations and safety, this study analyzed various cases of accidents, accident status, accident type, cause of the accident, location of the accidents, etc. from 2014 to 2018. The plans for improvement in education and nitrate accidents were reviewed. As a result, 36 nitrate chemical accidents were investigated, including 16 careless worker accidents, eight transportation accidents, and 12 facilities shortages. Nitrate chemical accidents are occurring continuously. Based on this, the range of toxic effects using CARIS was calculated at the worst-case scenario, and the effective response range was measured through the damage impact range. For this purpose, the impact range was predicted based on the strengthening of safety education, emergency action plan and correlation, and the quantified data was identified. In addition, the reliability of the scope of impact was reviewed based on the correlation formula that could facilitate the evacuation of residents, and it was applied to actual accident scenarios of the workplace to present the effects of the accident response and preventive measures.

Flood vulnerability analysis in Seoul, Korea (한국 도심지에서의 홍수취약성 분석)

  • Hwang, Nanhee;Park, Heeseong;Chung, Gunhui
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.10
    • /
    • pp.729-742
    • /
    • 2019
  • Natural disasters such as floods has been increased in many parts of the world, also Korea is no exception. The biggest part of natural damage in South Korea was caused by the flooding during the rainy season in every summer. The existing flood vulnerability analysis cannot explain the reality because of the repeated changes in topography. Therefore, it is necessary to calculate a new flood vulnerability index in accordance with the changed terrain and socio-economic environment. The priority of the investment for the flood prevention and mitigation has to be determined using the new flood vulnerability index. Total 25 urban districts in Seoul were selected as the study area. Flood vulnerability factors were developed using Pressure-State-Response (PSR) structures. The Pressure Index (PI) includes nine factors such as population density and number of vehicles, and so on. Four factors such as damage of public facilities, etc. for the Status Index (SI) were selected. Finally, seven factors for Response Index (RI) were selected such as the number of evacuation facilities and financial independence, etc. The weights of factors were calculated using AHP method and Fuzzy AHP to implement the uncertainties in the decision making process. As a result, PI and RI were changed, but the ranks in PI and RI were not be changed significantly. However, SI were changed significanlty in terms of the weight method. Flood vulnerability index using Fuzzy AHP shows less vulnerability index in Southern part of Han river. This would be the reason that cost of flood mitigation, number of government workers and Financial self-reliance are high.

A Study of the Effectiveness of Habitat for Humanity Korea's Disaster Risk Reduction Interventions: Focusing on the Mental Health of Residents of a Perennially Flooded Area in Southern Bangladesh (한국 해비타트의 재난위기경감 개입 효과성 연구: 방글라데시 남부 상습 침수지역 거주민의 정신건강 실태를 중심으로)

  • Suyeon Lee;Eunseok Seo;Goosoon Kwon
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.788-805
    • /
    • 2023
  • Purpose: This study aimed to verify the impact of Habitat for Humanity Korea's disaster risk reduction intervention on the mental health and satisfaction with life among residents of southern Bangladesh who had constantly suffered from disaster stress due to perennial flooding. Method: The target group was 138 residents who were pre-surveyed in August 2020 and post-surveyed in November 2021. The interventions consisted of individual incremental housing, public facilities for evacuation, and disaster response training for capacity development. The data were analysed using paired sample t-tests for pre-post changes and one-way analysis of variance to identify differences between treatment groups. Result: The results showed significant improvements in residents' depression, anxiety, somatisation and satisfaction with life after the intervention, with significant differences in mental health levels between the intervention treatments. Specifically, relatively higher disaster mitigation effects were found for individual infrastructure improvements and employment facilities compared to disaster response drills. Conclusion: These results demonstrate the positive role of Habitat for Humanity Korea's disaster risk reduction interventions on the mental health recovery of disaster victims and suggest practical approaches that can be applied in disaster risk areas.

PASTELS project - overall progress of the project on experimental and numerical activities on passive safety systems

  • Michael Montout;Christophe Herer;Joonas Telkka
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.803-811
    • /
    • 2024
  • Nuclear accidents such as Fukushima Daiichi have highlighted the potential of passive safety systems to replace or complement active safety systems as part of the overall prevention and/or mitigation strategies. In addition, passive systems are key features of Small Modular Reactors (SMRs), for which they are becoming almost unavoidable and are part of the basic design of many reactors available in today's nuclear market. Nevertheless, their potential to significantly increase the safety of nuclear power plants still needs to be strengthened, in particular the ability of computer codes to determine their performance and reliability in industrial applications and support the safety demonstration. The PASTELS project (September 2020-February 2024), funded by the European Commission "Euratom H2020" programme, is devoted to the study of passive systems relying on natural circulation. The project focuses on two types, namely the SAfety COndenser (SACO) for the evacuation of the core residual power and the Containment Wall Condenser (CWC) for the reduction of heat and pressure in the containment vessel in case of accident. A specific design for each of these systems is being investigated in the project. Firstly, a straight vertical pool type of SACO has been implemented on the Framatome's PKL loop at Erlangen. It represents a tube bundle type heat exchanger that transfers heat from the secondary circuit to the water pool in which it is immersed by condensing the vapour generated in the steam generator. Secondly, the project relies on the CWC installed on the PASI test loop at LUT University in Finland. This facility reproduces the thermal-hydraulic behaviour of a Passive Containment Cooling System (PCCS) mainly composed of a CWC, a heat exchanger in the containment vessel connected to a water tank at atmospheric pressure outside the vessel which represents the ultimate heat sink. Several activities are carried out within the framework of the project. Different tests are conducted on these integral test facilities to produce new and relevant experimental data allowing to better characterize the physical behaviours and the performances of these systems for various thermo-hydraulic conditions. These test programmes are simulated by different codes acting at different scales, mainly system and CFD codes. New "system/CFD" coupling approaches are also considered to evaluate their potential to benefit both from the accuracy of CFD in regions where local 3D effects are dominant and system codes whose computational speed, robustness and general level of physical validation are particularly appreciated in industrial studies. In parallel, the project includes the study of single and two-phase natural circulation loops through a bibliographical study and the simulations of the PERSEO and HERO-2 experimental facilities. After a synthetic presentation of the project and its objectives, this article provides the reader with findings related to the physical analysis of the test results obtained on the PKL and PASI installations as well an overall evaluation of the capability of the different numerical tools to simulate passive systems.

Selection of Retaining Wall System for Underground Parking Lots Expansion of Apartments (거주중 공동주택의 지하주차장확대를 위한 흙막이공법 선정)

  • Ro, Young-Chang;Lee, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.2
    • /
    • pp.99-107
    • /
    • 2008
  • Rapidly increasing automobile supply rate according to improved economic level of life makes lack of parking space of apartments. Even though the initial design of parking space compiled with old regulations, it may not observe either new laws or requirement of inhabitants. Even if old apartments have no structural durability problem, outworn facilities and insufficient parking area may be a main reason for reconstruction. It causes waste of national resources and makes recycling issues. Additionally, irregularly parked cars make traffic obstruction to a fire engine and result in many fire accident victims. Parking problems of apartments are not only inconvenience but also serious safety issues. From these points of view, remodeling only for parking area expansion is necessary to avoid overall reconstruction of apartments. The purpose of this study is to suggest a retaining wall selection method for apartments underground parking lots expansion without evacuation of resident people. Effect factors to select retaining wall system are analyzed and weight values are calculated by applying AHP. One selection method of retaining wall is proposed by evaluating applicability and its sensitivity analysis is executed. This selection method is expected to help decision-making of retaining wall system selection.

A Study on the Development of Facility Model for Safety Training Class in School (학교 내 안전체험교실의 시설모형 개발 연구)

  • Park, Sung-Chul;Ahn, Yoo-Jeong;Song, Byung-Joon;Cho, Jin-ll
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.2
    • /
    • pp.19-33
    • /
    • 2017
  • The purpose of this study is to derive education programs for safety training class, create unit spaces and present components and methods of utilizing the spaces for the development of facilities models closely related to various policy, operation plan and facility construction projects promoted by related institutions such as the Ministry of Education, schools, architects and companies. This study is divided into five steps. First, we reviewed the literature related basic directions for safety education and facility plan, second, field survey included both field conditions such as spatial size and facility configuration and analysis of operating conditions like hours of operation and personnel. Base on literature review and field survey, it were used to analyze strengths and weaknesses of existing safety training classes, and five facility models was developed based on the Delphi method and expert participatory design. The result show that the facility models (drafts) of safety training class were developed as follows: (1)the facility model for traffic safety(pedestrian safety, vehicle safety, subway safety) (2)the facility model for first aid(emergency rescue, how to report) (3)the facility model for disaster safety(fire evacuation safety, life earthquake safety) (4)the facility model for elevator safety(elevator safety, escalator safety) (5)the facility model for drugs and violence safety (smoking drinking, sexual harassment safety, food safety) The safety training class can be composed by combining or separating each module according to affordable space size of each school.

A Study on Plan for Introduction of Fire Influence Evaluation System through Risk Assessment of the Urban Lifestyle Housing Buildings (도시형 생활주택의 위험성 분석을 통한 화재영향성평가제도의 도입방안에 관한 연구)

  • Kim, Dong-Wook;Baek, Sona;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.10-17
    • /
    • 2017
  • Securing fire safety using only fire-fighting facilities is difficult because causes of modern fire vary, such as architectural structures and building use patterns. In order for fire safety to be guaranteed by enacting and revising fire regulations reflecting the fire hazard characteristics and user's characteristics, the introduction of fire influence evaluation (fire risk assessment) system needs to be considered in a timely manner to be adopted but unfortunately two attempts before have failed. In this study, a fire case of urban lifestyle housing was surveyed to introduce a fire influence evaluation system and a field survey on the actual condition of the 414 urban lifestyle housing buildings and fire & evacuation simulation results of one representative building in Suyoung-gu and Nam-gu District of Busan Metropolitan City were analyzed. The necessity, procedures and implementation method of fire influence evaluation system were questioned and tested by the professional fire experts, fire officers and firefighters and architects. On the basis of these facts, introduction of (fire influence evaluation system) should be absolutely adopted and the fire department and fire regulation are eligible to implement the system. Therefore, fire regulation needs to be enacted or revised in accordance with the new fire environment and fire safety system that needs to be built up. Accordingly, aggressive promotion through public hearings on the necessity of fire impact assessments, consensus among departments and fostering experts to carry out fire influence evaluation system will be the core.

A study on use of quantitative risk analysis on life safety performance for the effect of fixed fire fighting system at road tunnel fires (정량적 위험성 평가를 활용한 도로터널 화재시 물분무 소화설비의 피난 안전 효과 연구)

  • Park, Kyung-Hwan;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.1-22
    • /
    • 2012
  • This paper tried to verify whether the fixed fire fighting system (FFFS) that is installed in road tunnel improves evacuation performance or not. Verification was performed according to the Disaster Prevention Facilities Installation and Management Guide at Road Tunnel. Twenty seven different fire scenarios were set up for the verification and the cases that FFFS was installed were compared with the cases that FFFS was not installed. The result of the comparison showed that the average equivalent death was reduced in 26 cases out of 27 cases when water spray extinguishing system was installed. It was confirmed that the risk when was not installed was unacceptable in Hong Kong and the Netherlands. On the other hand, it was confirmed that the risk was reduced to as low as reasonably practicable (ALARP) when was installed. The cumulative frequency of average death in case with FFFS was compared against the frequency of death without FFFS: death of one or more is about 50 times less; 10 or more is about 100 times less; and the death of more than 100 is four times less. It was verified that FFFS makes improved conditions to escape from the fires in road tunnel.