• Title/Summary/Keyword: Error-BP

Search Result 102, Processing Time 0.021 seconds

Implementation of a Transmission Error Control Protocol for Biological Data in a Wireless Data Communication System (무선환경에서의 생체 데이터 전송 오류 제어 프로토콜의 구현)

  • Lim, Young-Ho;Yoon, Tae-Sung;Yoo, Sun-Kook
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.450-453
    • /
    • 2002
  • In emergency telemedicine system based on wireless communication system with limited transmission capacity, it is necessary to transmit the biological data (ECG, BP, Respiration, $SpO_2$) of the patient continuously and reliably in real time. For this service, it is necessary to data compression and error control. In this study, we designed an protocol for error control in application layer and implemented it on the biological data transmission program for an emergency telemedicine system based on wireless data communication system.

  • PDF

Adaptive PID controller based on error self-recurrent neural networks (오차 자기순환 신경회로망에 기초한 적응 PID제어기)

  • Lee, Chang-Goo;Shin, Dong-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.2
    • /
    • pp.209-214
    • /
    • 1998
  • In this paper, we are dealing with the problem of controlling unknown nonlinear dynamical system by using neural networks. A novel error self-recurrent(ESR) neural model is presented to perform black-box identification. Through the various outcome of the experiment, a new neural network is seen to be considerably faster than the BP algorithm and has advantages of being less affected by poor initial weights and learning rate. These characteristics make it flexible to design the controller in real-time based on neural networks model. In addition, we design an adaptive PID controller that Keyser suggested by using ESR neural networks, and present a method on the implementation of adaptive controller based on neural network for practical applications. We obtained good results in the case of robot manipulator experiment.

  • PDF

QR Decomposition Based Sequential Belief Propagation Detection Scheme for MIMO Systems (MIMO 시스템을 위한 QR 분해 기반 순차적 신뢰 전파 검출 기법)

  • Park, Sangjoon;Choi, Sooyong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.9
    • /
    • pp.1725-1727
    • /
    • 2015
  • In this letter, a QR decomposition based sequential BP detection scheme is proposed for MIMO systems. The proposed scheme performs the sequential updates from the observation node having the smallest degree among all the observation nodes. Our simulation results verify that the proposed scheme achieves an improved error performance with a significantly accelerated detection convergence speed compared to the conventional schemes.

Acceleration the Convergence and Improving the Learning Accuracy of the Back-Propagation Method (Back-Propagation방법의 수렴속도 및 학습정확도의 개선)

  • 이윤섭;우광방
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.8
    • /
    • pp.856-867
    • /
    • 1990
  • In this paper, the convergence and the learning accuracy of the back-propagation (BP) method in neural network are investigated by 1) analyzing the reason for decelerating the convergence of BP method and examining the rapid deceleration of the convergence when the learning is executed on the part of sigmoid activation function with the very small first derivative and 2) proposing the modified logistic activation function by defining, the convergence factor based on the analysis. Learning on the output patterns of binary as well as analog forms are tested by the proposed method. In binary output patter, the test results show that the convergence is accelerated and the learning accuracy is improved, and the weights and thresholds are converged so that the stability of neural network can be enhanced. In analog output patter, the results show that with extensive initial transient phenomena the learning error is decreased according to the convergence factor, subsequently the learning accuracy is enhanced.

  • PDF

A new training method for neuro-control of a manipulator (매니퓰레이터의 신경제어를 위한 새로운 학습 방법)

  • 경계현;고명삼;이범희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1022-1027
    • /
    • 1991
  • A new method to control a robot manipulator by neural networks is proposed. The controller is composed of both a PD controller and a neural network-based feedforward controller. MLP(multi-layer perceptron) neural network is used for the feedforward controller and trained by BP(back-propagation) learning rule. Error terms for BP learning rule are composed of the outputs of a PD controller and the acceleration errors of manipulator joints. We compare the proposed method with existing ones and contrast performances of them by simulation. Also, We discuss the real application of the proposed method in consideration of the learning time of the neural network and the time required for sensing the joint acceleration.

  • PDF

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals (다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상)

  • Jung, Woon-Mo;Sim, Myeong-Heon;Jung, Sang-O;Kim, Min-Yong;Yoon, Chan-Sol;Jung, In-Chol;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

A Study on Estimation of Systolic Blood Pressure using PTT (PTT를 이용한 수축기 혈압의 측정에 관한 연구)

  • Park E. K.;Lee S. M.;Han Y. H.;Lee J. Y.;Kwon S. Y.;Kim I. Y.;Kim Sun I.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.605-609
    • /
    • 2004
  • Blood pressure (BP) is one of the important physiological parameters for diagnosing cardiovascula diseases by means of noninvasive method. Existing noninvasive methods for measuring arterial BP have to use cuff and difficult in measuring arterial BP continuously. Systolic blood pressure (SBP) and pulse transit time (PTT) have a kind of inverse relationship. We acquired PTT data when subjects were in relaxation and also after exercise. We performed the linear regression analysis for making the regression equations for each subject and the regression equation for all subjects. We compared the estimated SBP with the measured SBP to check the accuracy of our regression equations. From the result, the regression equations for each subject was appropriate according to the American National Standards Institute of the Association of the Advancement of Medical Instrument (ANSI/AAMI) which says that BP devices should have ±5mmHg mean of error and 8mmHg standard deviation of error. However, the regression equation for all subjects was not proper to ANSI/AAMI recommendation. The result means that, without cuff, we can continuously estimate each subject's SBP through PTT and indivisual calibration.

Digital Blood Pressure Estimation with the Differential Value of the Arterial Pulse Waveform (맥파의 차동값에 의한 디지털 방식의 혈압 추정 기법)

  • Kim, Boyeon;Chang, Yunseok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.5 no.6
    • /
    • pp.135-142
    • /
    • 2016
  • We proposed the new method to estimate the blood pressure with the differential value of the digital arterial pulse waveform and BP relation equation. To get the digital arterial pulse waveform, we use the arterial pulse waveform measurement system that has digital air-pressure sensor device and smart phone. The acquired digital arterial pulse waveforms are classified as hypertension group, normal group, and hypotension group, and we can derive the average differential value between the highest point and lowest point of a single waveform of individuals along with the group. In this study, we found the functional correlation between the blood pressure and differential value as a form of BP relation equation through the regression process on the average of differential value and blood pressure value from a tonometer. The Experimental results show the BP relation equation can give easy blood pressure estimation method with a high accuracy. Although this estimation method has over 66 % error rate and does not give the high level of the accuracy for the diastolic compares to the commercial tonometer, the estimation results for the systolic show the high accuracy that has less than 10 % error rate.

On the Improving the pitch Searching Error of CELP Type Vocoder (CELP형 보코더에서 피치 검색오류의 개선)

  • 배명진;장호성
    • The Journal of the Acoustical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.62-67
    • /
    • 1993
  • 부호 여기된 선형예측 음성보코더들은 4800bps의 낮은 전송율에서도 좋은 음질을 제공한다. CELP 형 보코더의 피치검색법의 문제점중에 하나는 피치 검출시의 조오류에 의해 예측이득이 저하된다는 점이다. 본 논문에서 우리는 CELP 보코더의 피치 예측이득을 개선하는 한 새로운 피치검색법을 제안하였다. 제안한 방법은 예비피치들을 검출하여 이들중 피치 예측이득이 최대인 값을 선정하는 방법을 적용하였다. 이 방법을 여러 화자의 발성에 대해 적용한 결과 피치 예측이득율 6.1% 정도 개선할 수 있었다.

  • PDF